HomeMy WebLinkAboutCertified As Built PlanBVW.
TBM = EL. 30.0
TOP OF BOUND
28
I
98.20' I
75.87' 31 . I
31.5 I
I
31.1 I
+ +30.8
+31.5 30.7 /30.3
LOT 88/89
AREA=0.46 ACRES 28.5 /
30.6. T•0• @ EL. 31 .0
o
O of 28.21
+31.3 +31.3 0° I
2 .7
0
100 FT BUFFER ZONE I
1,500 SEPTIC I
1 T NK I
1 � I
-------- --------- G.
---------------- 30.0 J
---- -- 4 ------
0.00' O I
30A-- -1—
SEPTIC SYSTEM TIES
A-1:
37'3"
B-1:
15'7"
A-2:
30'1"
B-2:
21'5"
A-3:
29"
B-3:
49'5"
A-4:
45'7"
B-4:
84'
A-5:
36'5"
B-5:
53'8"
A-6:
52'7"
B-6:
88'3"
N_
DAISY LANE
5 FT. SOIL REMOVAL
(SEE NOTE 18)
28
�1r
®®
HOUSE CORNERS
m ®
1,5006 SEPNC TANK
®
- D -SOX
®
INSP PORE
® ®
- LEACHING CORNERS
5 FT. SOIL REMOVAL
(SEE NOTE 18)
28
27.6
SCALE: 1" = 20'
Lu
U
Lu
�.L
W
26.2
0
r
Q
odMD �B VW
27.2 JAN
0 2022
HEALTH DEPT.
WETLAND FLAGGING CONDUCTED
BY: BRAD HALL
SURVEY CONDUCTED BY:
WELLER AND ASSOC.
IYd�IIG�/_1:7IT, [fill [CI
LOCUS MAP
wextyk 11090• . ..
PLAN REF: 079/101
TITLE REF: 31748/241
PARCEL ID: MAP 119 PAR. 24
FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE
PROPERTY IS IN ZONE II
CERTIFIED AS BUILT
PLAN
LOCATED AT:
57 MAYFLOWER TERRACE
SOUTH YARMOUTH, MA
PREPARED FOR
GLENN MAXWELL
JANUARY 26, 2022
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
SHEET 1 OF 2
LEGEND
}—�
PROPOSED CONTOUR
®
PROPOSED SPOT GRADE
-- gg --
EXISTING CONTOUR
+ 96.52
EXISTING SPOT GRADE
—W—
EXISTING WATER SERVICE
&
TEST PIT
27.6
SCALE: 1" = 20'
Lu
U
Lu
�.L
W
26.2
0
r
Q
odMD �B VW
27.2 JAN
0 2022
HEALTH DEPT.
WETLAND FLAGGING CONDUCTED
BY: BRAD HALL
SURVEY CONDUCTED BY:
WELLER AND ASSOC.
IYd�IIG�/_1:7IT, [fill [CI
LOCUS MAP
wextyk 11090• . ..
PLAN REF: 079/101
TITLE REF: 31748/241
PARCEL ID: MAP 119 PAR. 24
FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE
PROPERTY IS IN ZONE II
CERTIFIED AS BUILT
PLAN
LOCATED AT:
57 MAYFLOWER TERRACE
SOUTH YARMOUTH, MA
PREPARED FOR
GLENN MAXWELL
JANUARY 26, 2022
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
SHEET 1 OF 2
PROPOSED 1,500 GALLON SEPTIC TANK
GAS BAFFLE TO BE INSTALLED ON
OUTLET TEE AS MANUFACTURED BY
THF -TITS 7ABEL. OR EQUAL
NOTES
1) CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE INVERTS PRIOR TO CONSTRUCTION
2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE
TO GRADE ON A MECHANICALLY COMPACTED SIX
INCH CRUSHED STONE BASE, AS SPECIFIED IN
310 CMR 15.221(2)
3) INSTALL INLET & OUTLET TEES W/
GAS BAFFLE AS REQUIRED
4) PLUMBING TO BE MODIFIED TO MEET OUTLET ELEVATION
AND LOCATION, PERMIT REQUIRED.
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPUCABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPGN ECTIEER D APPROVAL BY THE BOARD OF HEALTH AND THE
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
S. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
10. EXISTING LEACH PR TO BE PUMPED, CRUSHED AND FILLED PER TILE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY
13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING.
14. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED)
15. REMOVE ALL UNSUITABLE SOILS SIFT AROUND LEACHING TO EL 26.33
OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5.
SEPTIC SYSTEM
o DARREN M. y�
MEYER INV. ELEV.=27.41
NO,?' 1140%.1 END ELEV.=27.26
A£� E(tE� naue�3lsi�
'�NITAR�aa
BOTTOM EL.= 26.76
PROFILE SEPARATION 5.26FT.
ADJUSTED GROUNDWATER EL. 21.5
SOIL LOGS
DATE: DECEMBER 6, 2021
SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614
WITNESS: YARMOUTH HEALTH DEPARTMENT
Dov, TP -1
Depth
30.00
A
0"
LOAMY SAND
10YR 4/1
29.00
12"
B LOAMY SND
IOYR 5/6
26.33
44"
C
PERC TEST
O EL 25.0
MEDIUM -
SAND
2.5Y 6/4
20.0
120"
PERC RATE <2 MIN/IN. ('C' HORIZON)
GROUNDWATER OBSERVED AT
114" EL 20.50
WELL: MIW-29, ZONE A LEVEL' 7.9
ADJUSTMENT: I.W. USE BOH ALLOWED 1.0'
ADJUSTED GROUNDWATER EL 21.50
�e wm�+awwaEn®s�aet .�
C�
:• ::%:: S•�J:••:' .�
; ::Say �:� %S: ��:`":�;;�•
TEE'S ARE TO BE
:
1�.: �;7:
PVC
4" SCH •BAFFLE
:
•• S%Y ••• %;ttYt:• : Ott•:
l�t'1%: "t:Yt..•�� itt;tt� %;
;;� tats,J:l: t'�':
't�Y �� ��, ;�:;tt �'<.�,• J J.
GAS
..•'•
�:
PROPOSED 1,500 GALLON SEPTIC TANK
GAS BAFFLE TO BE INSTALLED ON
OUTLET TEE AS MANUFACTURED BY
THF -TITS 7ABEL. OR EQUAL
NOTES
1) CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE INVERTS PRIOR TO CONSTRUCTION
2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE
TO GRADE ON A MECHANICALLY COMPACTED SIX
INCH CRUSHED STONE BASE, AS SPECIFIED IN
310 CMR 15.221(2)
3) INSTALL INLET & OUTLET TEES W/
GAS BAFFLE AS REQUIRED
4) PLUMBING TO BE MODIFIED TO MEET OUTLET ELEVATION
AND LOCATION, PERMIT REQUIRED.
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPUCABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPGN ECTIEER D APPROVAL BY THE BOARD OF HEALTH AND THE
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
S. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
10. EXISTING LEACH PR TO BE PUMPED, CRUSHED AND FILLED PER TILE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY
13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING.
14. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED)
15. REMOVE ALL UNSUITABLE SOILS SIFT AROUND LEACHING TO EL 26.33
OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5.
SEPTIC SYSTEM
o DARREN M. y�
MEYER INV. ELEV.=27.41
NO,?' 1140%.1 END ELEV.=27.26
A£� E(tE� naue�3lsi�
'�NITAR�aa
BOTTOM EL.= 26.76
PROFILE SEPARATION 5.26FT.
ADJUSTED GROUNDWATER EL. 21.5
SOIL LOGS
DATE: DECEMBER 6, 2021
SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614
WITNESS: YARMOUTH HEALTH DEPARTMENT
Dov, TP -1
Depth
30.00
A
0"
LOAMY SAND
10YR 4/1
29.00
12"
B LOAMY SND
IOYR 5/6
26.33
44"
C
PERC TEST
O EL 25.0
MEDIUM -
SAND
2.5Y 6/4
20.0
120"
PERC RATE <2 MIN/IN. ('C' HORIZON)
GROUNDWATER OBSERVED AT
114" EL 20.50
WELL: MIW-29, ZONE A LEVEL' 7.9
ADJUSTMENT: I.W. USE BOH ALLOWED 1.0'
ADJUSTED GROUNDWATER EL 21.50
• I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017
to conduct soil evoluatiorre and that the above analysis has been performed by me consistent with the
requirements of 310 CMR 15.017. 1 further certify that 1 have passed the Soil Eval. Exam in October, 1999.
CIA.IEC NQ
FILTER FA
9" MIN COVER
BREAKOUT EL. = 56.08
SOIL ABSORPTION SYSTEM (SECTION)
DESIGN CRITERIA
NUMBER OF BEDROOMS: 4 BEDROOM DESIGN
SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF)
DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 110 G.P.D. X 4 BR = 440 G.P.D.
GARBAGE GRINDER: NO (not designed for garbage grinder)
SEPTIC TANK: 440 gpd x 200% = 880 gpd, PROP. 1,500 GAL. SEPTIC TANK
LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F.
USE 40'L X 15' W LEACHING FIELD WITH 3 LATERALS
BOTTOM AREA: 40 x 15 = 600 SF
TOTAL SQUARE FEET PROVIDED = 600 vs. 594.59 REQ'D
DESIGN FLOW PROVIDED: 0.74(600 S.F.) = 444 G.P.D. vs. 440 G.P.D. req'd
CERTIFIED SEPTIC SYSTEM AS BUILT PLAN
57 MAYFLOWER TERRACE, SOUTH YARMOUTH, MA
Prepared for: Maxwell
Design and Site Plan by: SCALE DRAWN DATE
MEYER &SONS, INC. N.T.S. DMM 01/26/2
PO BOX 981
EASTSANDW/CH, MA 02537 SHEET NO.
508-362-2922 2 Of 2