HomeMy WebLinkAboutEngineer Plans 2021Permit valid for REPAIR of SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for .any future additions/renovations%aherations to sewage facilities and/or structures/dwelling. BVW.Vanuouth Health Department ��jAPPROVED S77=0v 75.87 Name 31.1 + +30.8 31,5 30.7 LOT 88/89 AREA=0.46 ACRES +30.9 +3 1.3 31.3 I OO FT BUFFER ZONE o _ 0 30 -I --- 30.G T.O.,K@ EL. 31 .0 28.2 29. DAISY LANE K- TBM = EL. 30.0 TOP Of DOU14D 30.3 OEg�PROP. 1,5000 SEPTIC TANK ENNIMa • 5 FT. SOIL REMOVAL (SEE NOTE 18) I I I I 28 28 I I I I I I I I 27.2 LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE & TEST PIT .G SCALE: 1" = 20' <B VVv WETLAND FLAGGING CONDUCTED BY: BRAD HALL SURVEY CONDUCTED BY: WELLER AND ASSOC. SOUTH YARMOUTH LOCUS MAP LOCUS INFORMATION PLAN REF: 079/101 TITLE REF: 31748/241 PARCEL ID: MAP 119 PAR. 24 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE PROPERTY IS IN ZONE II SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 57 MAYFLOWER TERRACE SOUTH YARMOUTH, MA PREPARED FOR GLENN MAXWELL OFM,%EMBER 20, 2021 STEVE aW OF RUMS 1140 t .-t-z•til MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 J#2197 ELEV. TOP NOTE: PLACE ALL COVERS TO WITHIN 6" OF FINISH GRADE DROP FND. (Existing) = 31.0 �F.G.EL: 30.0 F.G.EL 30.0 F.G. EL: 30.0 y s 1 F.G.EL 29.05 PROP. OUTLET INV. 28.23 INV. 28.03 TEE'S ARE TO BE INV. 27.58 4" SCH 40 PVC INV 27.78 INV GAS PROPOSED DB -3 BAFFLE DISTRIBUTION BOX 59 "a (H20) ROPOSED 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE. ZABEL. OR EQUAL NUItJ: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED 4) PLUMBING TO BE MODIFIED TO MEET OUTLET ELEVATION AND LOCATION, PERMIT REQUIRED. 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE. TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACH PR TO BE PUMPED, CRUSHED AND FILLED PER TIRE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. ALL PIPING TO BE 4' SCH 40 O 1/8"/FF (UNLESS SPECIFIED) 15. REMOVE ALL UNSUITABLE SOILS 5FT AROUND LEACHING TO EL 26.33 OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE S. SEPTIC SYSTEM PROFILE NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE FINISHED GRADE (30.0) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 1% INV.= 27 27.35 INV. ELEV.=27.25 END ELEV.=27.05 3/4' - r-rri' DOUBLE WA9lio 6'RklE BOTTOM EL.= 26.55 SEPARATION 5.05FT. ADJUSTED GROUNDWATER EL. 21 SOIL LOGS DATE: DECEMBER 6, 2021 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: YARMOUTH HEALTH DEPARTMENT Bev. TP -1 Depth 30.00 A 0" LOAMY SAND 1UYR 4/1 zs.00 12" B LOAMY SAND 10YR 5/6 26.33 44" C PERC TEST O EL 25.0 MEDIUM - SAND 2.5Y 6/4 20.0 120" PERC RATE <2 MINAN. ('C' HORIZON) GROUNDWATER OBSERVED AT 114' EL 20.50 WELL: MRV -29, ZONE A LEVEL: 7.9 ADJUSTMENT: 1.5', USE BOH ALLOWED 1.0' ADJUSTED GROUNDWATER EL' 21.50 ' I. Darton M. Meyer, RS., CSE, hereby oerUfy that I am currently approved by MADEP pureuant to 310 CMR 15.017 to conduct will evaluations and that the above analysis has been performed by me wrialsterd with the requirements of 310 CMR 15.017. 1 further certify that I have passed the So# Eval. Exam M October, 1999. INSPECTION PORT TO GRADE 1- 40' OUl1EC No FIVER FA Yat 9" MIN COVER - 56.08 5' 1 SOIL ABSORPTION SYSTEM (SECTION) DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 4 BR = 440 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 440 gpd x 200% = 880 gpd, PROP. 1,500 GAL SEPTIC TANK LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F. USE 401 X 15' W LEACHING FIELD WITH 3 LATERALS BOTTOM AREA: 40 x 15 = 600 SF TOTAL SQUARE FEET PROVIDED = 600 vs. 594.59 REQ'D DESIGN FLOW PROVIDED: 0.74(600 S.F.) = 444 G.P.D. vs. 440 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 57 MAYFLOWER TERRACE, SOUTH YARMOUTH, MA Prepared for: Maxwell Design and Site Plan by: SCALE DRAWN DATE MEYER& SONS, INC_ N.T.S. DMM 12/20/2 roBOX 981 EASTSANDWICH, MA 02537 SHEET NO. 50-362-2922 2 of 2