Loading...
HomeMy WebLinkAboutEngineer Plans - 2022LOCUS DATA CURRENT OWNER SHELENA LEE & JASON HEALY PLAN REFERENCE 241-131—F1 DEED REFERENCE 29793-121 ZONING DISTRICT R-40 FLOOD ZONE "X" ASSESSORS MAP 87 PARCEL 169 OVERLAY DISTRICT STATE ZONE II LOT AREA 10,500± S.F. SITE & SEWAGE REPAIR PLAN #33 QUARTERUASTER ROW IN S. YARMOUTH, MASS DATE: JANUARY 25, 2022 OWNER/APPLICANT: JASON HEALY 33 QUARTERMASTER ROW SOUTH YARMOUTH MA 02664 SHEET 1 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS. SU R VEY <QYAH 00. COM :IIe3FytlLil fti PUMP, CRUSH AND REMOVE EXISTING z LEACHING PIT IN u ACCORDANCE WITH _ TITLE 5. PROPOSED °D` BOX PUMP, CRUSH — AND REMOVE EXISTING 'D° BOX PROPOSED S.A.S. (28) CHAMBERS " E 100- -104 1 1 5' N 1 1 1 1 D.T.H. #1 703 18.7' GARAGE ` \ E� EXISTING 1,000 GALLON SEPTIC TANK TO REMAIN JAN 2 8 2822 HEALTH DEPT. 3' 70 - SHEDD LIVING ROOM KITCHEN BATH B BED#1 ED#2 S 80 1?' 44° W 100.00' BENCHMARK, TOP OF CONCRETE BULKHEAD ELEVATION = 101,57 1 � 1 LOT 53 1 C3 1 10,500± S -F. 11 11 1 1 1 � Yarmouth Health 6 OpO N u5E R '(ONO ST9 "9l LOCUS LOCUS MAP NOT TO SCALE: ►.T►II�7i[iY� BED#4 BATH BED#3 c 7L -.—U-1— ,1�1 0 20 30 40 Name Date GRAPHIC SCALE: 1 INCH = 20 FEET 1 1 t 1 1 ,1 1 1 1 t N 1 1 1 1 1 5' N 1 1 1 1 D.T.H. #1 703 18.7' GARAGE ` \ E� EXISTING 1,000 GALLON SEPTIC TANK TO REMAIN JAN 2 8 2822 HEALTH DEPT. 3' 70 - SHEDD LIVING ROOM KITCHEN BATH B BED#1 ED#2 S 80 1?' 44° W 100.00' BENCHMARK, TOP OF CONCRETE BULKHEAD ELEVATION = 101,57 1 � 1 LOT 53 1 C3 1 10,500± S -F. 11 11 1 1 1 � Yarmouth Health 6 OpO N u5E R '(ONO ST9 "9l LOCUS LOCUS MAP NOT TO SCALE: ►.T►II�7i[iY� BED#4 BATH BED#3 c 7L -.—U-1— ,1�1 0 20 30 40 Name Date GRAPHIC SCALE: 1 INCH = 20 FEET SILL ELEV. 10.50 INV=EXISITNG JOB # 22-0102 SITE & SEWAGE REPAIR PLAN #ji QUARTERMASTER ROW IN S. YARMOUTH, MASS DATE: JANUARY 25, 2022 OWNER/APPLICANT: JASON HEALY 33 QUARTERMASTER ROW SOUTH YARMOUTH MA 02664 SHEET 2 OF 2 EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS. SU R VEY®YAH 00. COM CONSTRUCTION NOTES: 1. CONTRACTORS /INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ENGINEER TO VERIFY REMOVAL OF UNSUITABLE SOILS PRIOR TO INSTALLATION OF NEW SEPTIC SYSTEM. 4. NO PARKING OVER SEPTIC TANK IS ALLOWED. GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTIUTIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEP11C TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11, ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. �-2.83'-+--2.83'--�---2.83'--� -2.83'--I -11.33' SIDE VIEW DATUM: VERTICAL DATUM: ASSUMED BENCH MARK USED: TOP OF BULKHEAD ELEVATION 101.57 NO MOTTLING NO WEEPING D.T.H. #1 0 DATE: JAN. 13, 2022 GROUND ELEV. 102,+ ADJ G.WATER 90.9 A LOAMY SAND 10YR 4/4 8" INDICATES DEEP B DTH #1 0 TEST HOLE LOAMY SAND ■♦ 138" INDICATES ADJ. GROUNDWATER ELEV = 99.4 NO OBSERVED GROUNDWATER INDICATES PERC TEST GROUNDWATER ADJUSTMENT DEPTH TO BOTTOM OF HOLE 11.5 VARIANCES REQUESTED NONE C COARSE SAND 10YR 7/6 i3l*TAMWI41L 36" 138" B.O.H. PHIL RENAUD SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. ELLIS BROTHERS SOIL TYPE: i PERC RATE: Q MIN. PER INCH LOADING RATE: 0.74 GAL/SF/MIN SYSTEM DESIGN RAISE COVERS TO WITHIN 6" OF FINISH GRADE (2) OBSERVATION PORTS TO DESIGN FLOW FINISH GRADE. GRADE / SCREW ON CAP 4 BEDROOMS AT110 GPB/D 4410- GPD ELEV. 101.6 ELEV. 102. 102.0 GROUND ELEVATION 102.7 REQUIRED SEPTIC TANK - �� ___� 6'®S= 0.01 3' OF COVER MAX TOP ELEV 99.17 _ 440 x 2 = 880 GAL. 8' ®S= 0.01 4" PVC SCH 40 STRIPOUT TO "C" EXISTING SEPTIC TANK = _-1 0QO_GAL. MIN_3 MAX TOP OF 99.22 10"TEE 14"TEE INV.= 'arno is HORIZON SIZE OF LEACHING FACILITY REQUIRED 99.05 6" PER 310 CMR GAS BAFFLE H-20 DB6 15.255 (C) 440 -.0.74 SF/GPD = 596 S.F. MIN. REQ. 4'-i" LIQUID LEVEL 0 -BOX INV.=98.97 INV98.74 c? USING 28 ADS H-20 ARC 36 HC CHAMBERS INV.= 98.80 p a UNITS AND NO STONE AROUND 35.0' V. 97.84 o USING 28 (4 ROWS OF 7) STONELESS UNITS USE (28) ADS H-20 ARC 36 HC tO "ADS H-20 ARC 36 HC" WITH END CAPS EXISTING 1000 GALLON SEPTIC CHAMBERS TOTALING 140 LINEAR FEET--ELEV. 90.9 4,8 SF / LF X (5' x 28) = 672 S.F TANK TO REMAIN 60"04"x16" STONELESS BED FORMATION ADJ. G.WATER TH#1 = 672 x 0.74 G/SF 497 GPD ( 4 ROW OF SEVEN PANELS) NO (GARBAGE DISPOSAL / GRINDER ALLOWED) SITE & SEWAGE REPAIR PLAN #ji QUARTERMASTER ROW IN S. YARMOUTH, MASS DATE: JANUARY 25, 2022 OWNER/APPLICANT: JASON HEALY 33 QUARTERMASTER ROW SOUTH YARMOUTH MA 02664 SHEET 2 OF 2 EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS. SU R VEY®YAH 00. COM CONSTRUCTION NOTES: 1. CONTRACTORS /INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ENGINEER TO VERIFY REMOVAL OF UNSUITABLE SOILS PRIOR TO INSTALLATION OF NEW SEPTIC SYSTEM. 4. NO PARKING OVER SEPTIC TANK IS ALLOWED. GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTIUTIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEP11C TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11, ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. �-2.83'-+--2.83'--�---2.83'--� -2.83'--I -11.33' SIDE VIEW DATUM: VERTICAL DATUM: ASSUMED BENCH MARK USED: TOP OF BULKHEAD ELEVATION 101.57 NO MOTTLING NO WEEPING D.T.H. #1 0 DATE: JAN. 13, 2022 GROUND ELEV. 102,+ ADJ G.WATER 90.9 A LOAMY SAND 10YR 4/4 8" INDICATES DEEP B DTH #1 0 TEST HOLE LOAMY SAND ■♦ 138" INDICATES ADJ. GROUNDWATER ELEV = 99.4 NO OBSERVED GROUNDWATER INDICATES PERC TEST GROUNDWATER ADJUSTMENT DEPTH TO BOTTOM OF HOLE 11.5 VARIANCES REQUESTED NONE C COARSE SAND 10YR 7/6 i3l*TAMWI41L 36" 138" B.O.H. PHIL RENAUD SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. ELLIS BROTHERS SOIL TYPE: i PERC RATE: Q MIN. PER INCH LOADING RATE: 0.74 GAL/SF/MIN