HomeMy WebLinkAboutSite Plan 1-13-22LEGEND zjyj - LXIJIINU UUNIUUM X 99• 1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 TEST HOLE 2% SLOPE OF GROUND CQ) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING RIVERFRONT MITIGATION CALCULATIONS: HARDSCAPE 0-100' 100-200' EXISTING: 3490 SF 3305 SF PROPOSED: 3270 SF 7290 SF CHANGE: -220 SF 3985 SF REQUIRED MITIGATION 3765*2 = 7530 SF (7600 SFf PROVIDED), MEADOW MIX New England Wildflower Mix NEW ENGLAND WETLAND PLANTS, INC. OR EQUAL SPECIES: Little Bluestem, (Schizachyrium scoparium), Creeping Red Fescue, (Festuca rubra), Indian Grass, (Sorghostrum nutans), Partridge Pea, (Chamaecrista fasciculato), Canada Wild Rye, (Elymus canadensis), Virginia Wild Rye, (Elymus virginicus), Wild Blue Lupine, (Lupinus perennis), Golden Alexanders, (Zizia aurea), Ox Eye Sun"ower, (Heliopsis helionthoides), Black Eyed Susan, (Rudbeckia hirta); New England Aster, (Aster novae-angliae), Wild Bergamot, (Monarda stulosa), Smooth Blue Aster, (Aster laevis), Evening Primrose, (Oenothera biennis), New York Ironweed, (Vernonia noveboracensis), Grass Leaved Goldenrod, (Euthamia grominifolia), Early Goldenrod, (Solidago juncea). LICE #21-158 *THE INSTALLER SHALL VERIFY THE \ LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 wlTnll cc• CAROL EASTMAN DATE: 1 1 /29/21 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 4 , 4 0„ 5 0„ A LS 14" 1OYR 4/1 B LS 30" 1 OYR 4/6 2.5' PERC W 2.5Y 7/6 ELEV. 6' A LS IOYR 4/1 18" B LS 30" 1OYR 4/6 3.5' 96" I I -3' 96" G-W ADJ. DATA: GROUNDWATER AT 48" WELL: MIW 29 ELEVATION 1.0' ZONE: A ADJ: 1.5' DECEMBER 2021 " MS 2.5Y 7/6 PROVIDE MIN. 20" DIAM. WATERTIGHT PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO GRADE ACCESS COVERS TO GRADE D. EL. 12.2' 9 5' MINIMUM .75' OF COVER OVER PRECAST 1 O MINIMUM 3 OF COVE PRECAST H-10 RISERS (TYP.) PRECAST H-10 RISERS (TYP.) z'0 H-20 H-20 I.I 10" 2000 GAL 10" 2000 GAL 7.25' TEE SEPTIC TANK 7 00' g 96 TEE PUMP CHAMBER ZABEL A100 FILTER PRIOR SEE DETAIL BELOW TO P/C 4' LIQ. LEVEL (ACME OR EQUAL) J00O O O O O •O; O O O O O 0; O^ O O O O O o O�'l. Jpo0000000000p000 a00000000000000000000000a( • 0080 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 0 0 0 o a o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0< „0000o0ono0o„o,,0,,00000000o0o�onono„o„o„00000. o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 � � _ _ '�`O ,,O„O..n_n„7,.'1_'1 O o O o O n_n_n_n_n„7.0 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) ( 2.5 % SLOPE) ( 2 % SLOPE) FOUNDATION- 15' SEPTIC TANK 21 ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP INV. IN 6.96' ALARM ON FLOAT SWITCH SETTINGS: PUMP ON 4" WORKING RANGE PUMP OFF 2000 GAL. H-20 S 1245 GAL. RESERVE 8„ 4" 12" SYSTEM PROFILE (NOT TO SCALE) MARK CORNERS OF LEACHING FIELD W/ PROVIDE INSPEC1ON PORTS TO REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE GRADE 2% SLOPE \ FILTER FABRIC fER PRECAST TOP 8.68' \\\ 9.5 FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. IX 0 r fill MIN. SUMP 4" OSCH40 PVC CLEAN FILL PIPES LEVEL 1ST 2' 12" MIN. INT. DIM. a PERFORATED PVC 5' O.C. S=O.005 O ' EE'. o 3/4"-1-1/2" DOUBLE WASHED WATERTEHT D'BOX loll STONE LEACHING FIELD 0 6"DEPTH MIN BELOW INV. 000000000000 O 8.0' 0g000o00 FOR LEVELNESS 8.33' LEVEL BOTTOM o 8.62' 8.45' 54.0' 7.5' (1 v. SLOPE) PUMP CHAMBER 90' D' BOX 12' PROP. WATERTIGHT COVER TO GRADE SYSTEM DESIGN: ,PROVIDE QUICK DISCONNECT FOR PUMP GARBAGE DISPOSER IS - NOT ALLOWED ..//</ NO LOW POINTS 2" PRESSURE LINE - -- SLOPE TO DRAIN BACK TO PC -0.25" WEEP HOLES CHECK VALVE MYERS SRM 4 PUMP CHAMBER (NOT TO SCALE) WATERPROOF/WATERTIGHT MAP 34 PARCEL 292.1 JOSEPH GILMORE rnrnr nncnnn SUBMERSIBLE 4/10 HP PUMP SYSTEM (OR EQUAL) #181 EXISITNG 6 BEDROOMS #183 EXISTING 3 BEDROOMS DESIGN FLOW: 9 BEDROOMS @ 110 GPD = 990 GPD USE A 990 GPD DESIGN FLOW SEPTIC TANK: 990 GPD (2) = 1980 USE A 2000 GAL. SEPTIC TANK AND A 2000 GAL. PUMP CHAMBER LEACHING: 990 GPD / (.74) = 1338 SF REQUIRED 25' X 54' = 1350 SF OK 1350 SF X .74 = 999 GPD OK USE A 25' X 54' PIPE AND STONE LEACHING FIELD 5. 0' ADJUSTED GROUNDWATER 2.5' LEACHING BUOYANCY CALCS: FACILITY H-20 2000 GAL. PC WEIGHS 26,000 LBS 1.64' x 6 x 11 x 62.4 = 6,755 LBS UP (OK) H-20 2000 GAL. ST WEIGHS 26,000 LBS 1.33' x 6 x 11 x 62.4 = 5,478 LBS UP (OK) ZONING SUMMARY ZONING DISTRICT: RS-40 RESIDENTIAL DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 40,000 S.F. 85,850 S.F. 85,850 S.F. MIN. LOT FRONTAGE 150' 149.94' 149.94' MIN. FRONT SETBACK 30' 289' 318' MIN. SIDE SETBACK 20' 14.6' 23.6' MIN. REAR SETBACK 20' - - MAX. BUILDING COVERAGE 25% 6.0% 6.9% eye or/,in � ow t Cb o N = S � J P oa a r. Uth Shore D Nantucket Sound LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 34 PARCEL 292.2 LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 11) & VE (EL 13) AS SHOWN ON COMMUNITY PANEL #25001 CO589J DATED 7/16/2014 PROPOSED DWELLING IS WITHIN AE (EL 11) DESIGN FLOOD ELEVATION 12.0 NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-20 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. POOL FENCE SHALL HAVE SELF -CLOSING SELF -LATCHING GATES, SIZE AND MATERIALS TO MEET LOCAL AND STATE BUILDING CODE, ALL DWELLING DOORS OPENING TO POOL SHALL BE ALARMED TO CODE. 14. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. WATER RESISTANT CONSTRUCTION UP TO ELEVATION 12.0. 15. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. 16. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW MANUFACTURER'S SEPCIFICATIONS FOR PROPER FILTER INSTALLATION. 17. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. OF # 181 R I V E Fl"" T R E E T SOUTH PREPARED FOR JOSEP" DATE: JANUARY 13, 2022 �9 Scale:1 "= 20' 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P.E., P.L.S. off 508-362-4541 fax 508-362-9880 downcope.com O WO cape, engii leriog, Mc. civil engineers land surveyors 939 Main Street ( Rte 5A) YARMOU THPOR T MA 02575 DCE #21-158