HomeMy WebLinkAboutEngineer Plan - 2021TOP OF FOUNDATION ' _ �20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE ELEV. = 100.00 10 FT MINIMUM 10 FT. MINIMUM FROM SLAB � c CLEAN SAND (ASSUMED) CONCRETE \^ INSPECTION Pop COVERS 4" SCHEDULE 40 PVC PIPE LOAM AND SEED T MIN. PITCH 1/8" PER FT. 2_APER OF 1/4' TOTO WASHED STONE 3.03 4' CAST IRON PIPE 99,0 MAX OR .ILTER FABRIC VENT (OR EQUAL) MINIMUMp��� 96:75 MMI. NOT REQUIRED P-:TCH 1/4" PER FT. 9B.0 LEYEOW 5 TEE ITS J 3 ELEV. _ els_ "{'MIN.20" "-------T=-° ❑aadaQaQQad i LEV, LEVEL ° ° QQaaaaOdC7d ° ° ELEV. _ _9M.7S ADD GAS J6" SMP ° BAFFLE ELEV. _ _.3Q ELEV. I ` ° ° ° daQQdooaadc? I° 2' ° DISTRIBUTION ° UID OUTLET ELEV. _ ° a° Qa 1dCDaQQaQC �° ° 93.25 4 FEET 14 IN HES (EXISTING) 80 -- _ ELEV. _ 5 FEET 19 INCHES /�� /�A' , /y� TO BE WATER TESTED 3 500 GALLON GALLEYS WITH + 6 FEET .4 INCHES 1CWV{'1.GALLON IF MORE THAN ONE OUTLET STONE IN AN - 8 FEET 29 INCHES SEPTIC TANK (TO BE PLACED ON' FIRM BASE) 13' X 25' X 2' TRENCH FC*:MATION I � WELL _N1A_,_- .ry p�+�p� ! j - 833 ZONE _ 3/4" TO 1 ./2" CLEAN SNL ABSORPTIOr INDEXT DOUBLE WASHED STONE FREE OF FINES k SILTSYSTEM (SAS) ADJUST__ USGS PROBABLE WATER "ABLE ELEV. - SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED WATER TABLE( / ) ELEV. _ NOT TO TO SCALE BOTTOM OF TEST HOLE ELEV. _�_. ORTNr tASE -0.6#21 (� L SOIL TEST DATE OF SOIL TEST MgRCI� SOIL TEST DONE BY SWKE'`-ER ENGNG WITNESSED. BY _M,,.,,J,A[V, Cj, F _A„ OBSERVATION HOLE 1 PERCOLATION RATE _ < MIN./INCH AT _ 36 -- INCHES DEPTH IHORIZI TEXIJRICOLOR MOTT OTHf"R 0-3" Ap 3-t 32" C LOAMY SAND tOYR4/1 _ MED./COARSE SAND 2.5Y7%4 NO NOB NO WATER ENCOUNTERED AT _ i 3? _ ELEV. _ _ 87.6 _ DESIGN CALCULATIONS NUMBER OF BEDROOMS 3 GARBAGE DISPOSAL UNIT _ TOTAL ESTIMATED FLOW ( 110 OAL/6R./0AY X " ,'L_ BR.) _ . Q_ GAL. jDA Y REQUIRED SEPTIC TANK CAPACITY;�, GAL. ACTUAL SIZE OF SEPTIC TANK (EXISIM ) 16 GAL. SOIL CLASSIFICATION 1_ �.' DESIGN PERCOLATION RATE 5_MIN./IN. EFFLUENT LOADING RATEGAL./DAY/'S.F. LEACHING AREA 4 S0, FT __. LEACHING CAPACITY (AREA X RATE) -JUM GAL /DAY 477.00 X 0.74 RESERVE LEACHING CAPACITY NOW GAL./DAY Perwlll vallll 161 1161'\IN Ilr �I 1 n/' sr�1'F.M (/N 1.\, eynaed for due IU \1'111' „M/ IAI"'.1tl lic \NI IAOI't& 9lnrdul Iletllh n.u•� + + .pp,ue d ,. r llSay111/Nfe ed JdluOy^IrOp� llp �.. dIPgllNlfl\ lu sewer IM61#11" A^d/IN sir uclu/c�:Jarllnik. 69.6 00. Yarpl„ulh IIca11D 1x1,:+, Imcxl 135' AI'PROV I'D 4 12,7w 85.5 �r 1 } NOW 1 fol ..- , ) \ --- 97.5 -\ , +_" } A 1 98.�} \\ # }} 84,2 01, IaE 98.4 1 11 1 9901 0H ...vmi= i� 41i DEGy- 2 w SOIL } TEST 9.1- 983 TAR x O ` 1000 GALLON D. SEPTIC TANK 8-7 BOX 48.4 O LEGEND: EXISTING SPOT ELEVATION 00.0 EXISTING CONTOUR ----DO---- FINAL SPOT ELEVATION FINAL CONTOUR--•---{C---- SOIL TEST LOCATION v UTILITY POLE --O•- TOWN WATER -WSW-- CATCH BASIN®1 GAS UNE G CLEAN OUT CESSPOOL C.P. 0 \ \ (I'DO ' 4 h� LOT 12 I{ 30,000.8 t S.F. PIT 80 10 I1 NOTES - 1 , ALL WORKMANSHIP. AND MATERIALS SHALL CONFORM TO D,E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3, ALL COMPONENTS OF THE SANITARI SYSTEM SHALL BE CAPABLE OF WITHSTANDING H --IO LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-24 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4 ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANTS IS TC OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY 6 UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR r 7233 AT LEAST 72 HOURS VOIC WORK ON SITE, ANY VARI. In f, i 8. PARCEL IS IN FLOOD ZONE -- X 9. LOT JS SHOWN ON ASSESSORS MA AS PARCEL 10. ALL UNSUITABLE MATERIAL SHALL BE MOVED FROM UNDER AND ! FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15,255:(3). 11. E INSTALLER IS TO GIVE THE ENGINEER A MINIMUM OF 48 HOURS 2 WORKING DAYS) NOTICE FOR THE FINAL INSPECTION (NUMBER BELOW). 2 EXISTING PIT IS TO BE PUMPED AND BACKFILLED WITH SAND, MAR 1 1 2021 1 H ,.z If APPROVED. BOARD. OF HEALTH. i j 3 I DATE Gr;7NT - wG 6a 2012': SOUTH YARMOUTH, MA G 03 C T O0�\ G L(x,'(j,'� S �� 0 -- P POSED SEPTIC DESIGN ,11 JOHN ROSS 21 MOORING LANE, LOT 12 SOUTH SOUTH YARMOUTH,y MASS. 508- swx o SETUCKET ROAD 7131 385-6900 SOUTH DENNIS � MASS. 02660 DAIEMAR. 2, 2021 ' sI cnLE 20 wo LOCATION MAP CI+F FRE`v wG 6a 2012':