Loading...
HomeMy WebLinkAboutEngineer Plan - 2022LOCUS 4 LOCATION AP LOT 0 (9,466M 9466 SF) ASSESSORS MAP:40 PARCEL:40 PLAN BOOK: 149, PAGE: 95 APPROXIMATE AREA OF 4INFILTRATORS WITH T OF STONE AND ONE 4' PIT WITH T OF STONE. (SEE NOTE 13) KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: •---------•- EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: Y UTILITY POLE: -o- FENCE LINE: - HYDRANT: RETAINING WALL: ® �- 102 a � / G 1 / tie ret. wall / 36" oak n i A rT a \ \ 103 2 01 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 5 BEDROOMS AT 110 GAL / DAY = 550 GAL / DAY SEPTIC TANK: 550 GAL/ DAY x 2 DAYS= 1100 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) LEACHING AREA: USE 42 INFILTRATOR QUICK 4 PLUS HIGH CAPACITY CHAMBERS AS SHOWN (21'x 26'x 8" EFF. DEPTH) SIDE AREA: NA (0.74) = NA GAL/DAY BOTTOM AREA: 4'x 42 UNITS x 4.7 = 790 SF (0.74) = 585 GAL/DAY CAPACITY = 585 GAL/DAY LEACH AREA DETAIL \Ok2' O< �r 0, O \ W \ 104.0 ���. SY \ A rQp�FFO ,2 F J '�"V1' 10YR 4/1 103.5 cb BENCHMARKAT LEFT CORNER OF CONCRETE STEP ELEVATION = 104.21 103 (EXISTING) (EXISTING) 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP. 14" DOWN BED BED ROOM ROOM LIVING FAMILY ROOM ROOM BED ROOM TBATHT KITCHEN ggTH EXISTING FLOOR PLAN 1/8" per ft D -BOX (6" OF STONE UNDER) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS BED ENGINEER: THOMAS MCLELLAN, P.E. ROOM WITNESS: PHIL RENAUD DATE: 1-6-22 PERCOLATION RATE: <2 MIN/IN BED ROOM Yarmouth Health Department APPROVED Sr27��f.eti r<tti4/1� rr 2a. Name Date USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: B, ADJUSTMENT: 2.2' ADJUSTED GROUND WATER ELEV.= 95.2 AIN 8" EFF. DEPTH INLET. IT'S ON INSPECTION PORT � ELEV.= 101.4 100.9 II 1 1.11.1 1.1 1°I 1`I N 1.1 PI 1.1 PI N 1.1 M I -I N 11 100.23 :LEV. ELEV. e 21'x 26' USE 42 INFILTRATOR QUICK 4 PLUS 5.03' HIGH CAPACITY CHAMBERS AS SHOWN (21'x 26'x 8" EFF. DEPTH) ADJUSTED GROUNDWATER ELEVATION= 95.2 TH-1 104.0 ELEV. O/A HORIZON LOAMY SAND 10YR 4/1 103.5 B HORIZON LOAMYSAND 10YR 5/8 101.5 C HORIZON MEDIUM SAND 2.5Y 7/4 PERC AT 48" NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 114" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. ' 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SURJFCT TO CHANAP 1 INTII CI ICH TIME THIP PI AAI PA4 RCCAI PDP0A0=n CnD TPC ClII C REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH PIT AND SPOILS ARE TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND, IF ALREADY DONE SO. EXISTING INFILTRATORS ARE TO BE ABANDONED IN PLACE. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. SITE PLAN LOCATION: aZN OF 4%. 7 CANDLEWOOD LN., W. YARMOUTH, MA c THOMAS J. yN PREPARED FOR: ""`FELLA" CIVIL EDWARD OSULLIVAN (; No. 36471 SCALE: 1" = 20' LS�BASS RIVER ENGINEERING V THOMAS J. MILE N, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048