Loading...
HomeMy WebLinkAboutEngineer Plan - 2022SYSTEM PROFILE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 67.9' PRECAST H-111 RISERS (TYP.)11 2'm 60.5' EXISTING 1000 GAL. 10" SEPTIC TANK** 14" TEE TEE GAS 17'* 54.77 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (6i SLOPE) (NOT TO SCALE) 4"OSCH40 PVC PIPES LEVEL 1ST 2' WATERTEST D'BOX FOR LEVELNESS (26.7%, SL FOUNDATION— EXIST. — SEPTIC TANK 22' D' BOX 6' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEND- -- 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH1 TEST HOLE SLOPE OF GROUND 71) UTILITY POLE �ql FIRE HYDRANT NOTE. NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE WITNESS: PHIL RENAUD DATE: 1/6/22 PERC. RATE _< 2 MIN/INCH CLASS I SOILS 13871 4 ELEV. i 0" 57.0' A LS 6 1OYR 4/2 B LS 1OYR 5/6 48" 53.0' C PERC MS 1OYR 7/4 132" 46_0' NO GROUNDWATER ENCOUNTERED DICE #21-463 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 5 NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-12 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. B. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 123 PARCEL 69 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO578J DATED 7/16/2014 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 RE—USE EXISTING 1000 SEPTIC TANK** LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) HIGH CAPACITY UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 4 UNITS 16 UNITS x 29.5 SF = 472 SF > 445.9 SF 472 SF (0.74) = 349 GPD (OK) M'45 Z f I ±Roza, y> c , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF FEB d 9 2022 66 RANDOLPH RD. HEALTH DEPT, YARMOUTH PORT. PREPARED FOR Scale: 1 "= 20' 0 10 20 30 40 50 FEET FLOOR PLAN (N.T.S.) r DATE DANIEL A. OJALA, P.E., P.L.S. TOLOTTI CONSTRUCTON/I ROBERT PHILLIPS DATE: JANUARY 11, 2022 off 508-362-4541 fax 508-362-9880 downcope.com dowel cape eagineefing, MC. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTFfPORT MA 02675 21-463 BORTOLOTTI-PHILLIPS. DWG