Loading...
HomeMy WebLinkAboutEngineer Plan -2002L O r7 z Q J O U J MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED: 1. VARY LEACH AREA TO LOT LINE BY 5' (5' PROVIDED). VARY LEACHING TO BASEMENT BY UP TO 12.5' (7.5' & IMPERVIOUS BARRIER PROVIDED). VARY SEPTIC TANK TO CRAWL SPACE BY 3.7' (7.3' PROVIDED). VARY SEPTIC TANK TO LOT LINE BY 5' (5' PROVIDED). 310 CMR 15.211 (1). N /F POMEROY N /F LEADER LEGEND TH 1 TEST HOLE LOCATION, NUMBER -W- WATER LINE MARKINGS -G- GAS LINE MARKINGS 9.5' x 8,7 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) ,--6-- EXISTING CONTOUR -8- PROPOSED CONTOUR N /F SCLAFANI S79 U) EXISTING 8 USE 1 o�:, b0 en,ent : CV m. 31.1 i,3 - 4­132,30�'f- , 323..- N /F PAMBOOKIAN BENCH MARK --TOP & CENTER OF CONC. BOUND= 31.65 ASSIGNED F_ *TOP BARRIER=28.0 BOTTOM BARRIER= 23.0 5' DEEP* IMPERVIOUS BARRIER --60 L.F. OF 40 MIL POLYETHYLENE SET 6' OFF BUILDING TOP BARRIER=TOP PEASTONE=27.7 ** BARRIER IS STIFF & OBTAINABLE FROM MILLER ENVIRONMENTAL 508-697-3710. 0 0 _ J, \REMOVE PAVEMENT OVER PROPOSED LEACHING AND PROVIDE H2O DRY WELLS IN CASE VEHICLES PARK ON GRASS. LOT 96,=` Clasby2.dwg- 101049±S.F. 25 X t�v83 n clean o--�► „ r = e. ut C ' 32R crawl 1� patio Spoce I1 conc. J 1 � U) EXISTING 8 USE 1 o�:, b0 en,ent : CV m. 31.1 i,3 - 4­132,30�'f- , 323..- N /F PAMBOOKIAN BENCH MARK --TOP & CENTER OF CONC. BOUND= 31.65 ASSIGNED F_ *TOP BARRIER=28.0 BOTTOM BARRIER= 23.0 5' DEEP* IMPERVIOUS BARRIER --60 L.F. OF 40 MIL POLYETHYLENE SET 6' OFF BUILDING TOP BARRIER=TOP PEASTONE=27.7 ** BARRIER IS STIFF & OBTAINABLE FROM MILLER ENVIRONMENTAL 508-697-3710. 0 0 _ J, \REMOVE PAVEMENT OVER PROPOSED LEACHING AND PROVIDE H2O DRY WELLS IN CASE VEHICLES PARK ON GRASS. S79 0,20" W 6 0.00' 30.08 N /F MAGUIRE * 297X69 R� 29.46 '7725 'F 1 BROOK � 30,00 SW REV. 10/8/02 --MOVE SEPTIC TANK & LEACHING 1� 961 Clasby2.dwg- 27'7 -Top Peastone Invert 28.25 1500 Gal. T 4 1 m 1 24"126" 1 v 1 ELEVATIONS SHOWN ARE ASSIGNED. 1 A 1 3. LOCUS IS IN FLOOD ZONE C ON FIRM DATED JUNE 17, 1986.4. 1 m 1 S79 0,20" W 6 0.00' 30.08 N /F MAGUIRE * 297X69 R� 29.46 '7725 'F 1 BROOK � 30,00 SW REV. 10/8/02 --MOVE SEPTIC TANK & LEACHING 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0 TEST HOLE DATE: June 19, 2002 12" NO GRADE CHANGES PERFORMED BY: Ron Cadillac, Soil Evaluator ARE PROPOSED WITNESSED BY: Amy Von Hone, RS, CHO 14" PERC RATE: <2'-00"/inch (C layer) 32.82± SOIL SURVEY(1993): Carver coarse sand 42„ GEOLOGIC MAP(1986): Harwich outwash plain deposits TOP OF FOUNDATION Invert 28.00 a Invert 28.80 3 DRY WELLS 56" Use Gas Baffle Invert 27.27 Proposed Proposed Proposed S=1/4"/ft 9" min. cover 28.0=Top Conc. NOTES Clasby2.dwg- 27'7 -Top Peastone Invert 28.25 1500 Gal. T Proposed LOCUS IS A.M. 67, PARCEL 226. 24"126" 2. ELEVATIONS SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE C ON FIRM DATED JUNE 17, 1986.4. Invert 27.44 Invert 27.20 ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)5. 6" Stone or compact MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. TALE1. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. r- 27'-, 1 N I 1 I 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14".8. m 7' Bottom IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW DATA D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. BUILD UP COVERS TO WITHIN 1' OF GRADE. MORTAR CHIMNEYS IN PLACE. ONE COVER OF TANK TO BE WITHIN 6" OF GRADE. 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING TEST HOLE 1 IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0 TEST HOLE DATE: June 19, 2002 12" NO GRADE CHANGES PERFORMED BY: Ron Cadillac, Soil Evaluator ARE PROPOSED WITNESSED BY: Amy Von Hone, RS, CHO 14" PERC RATE: <2'-00"/inch (C layer) 32.82± SOIL SURVEY(1993): Carver coarse sand 42„ GEOLOGIC MAP(1986): Harwich outwash plain deposits TOP OF FOUNDATION Invert 28.00 a Invert 28.80 3 DRY WELLS 56" Use Gas Baffle Invert 27.27 Proposed Proposed Proposed S=1/4"/ft 9" min. cover 28.0=Top Conc. Fill A layer 10yr 2/1 loamy sand B layer 1Oyr 5/6 sandy loam C layer 2.5y 6/6 med. fine sand no water BEDROOMS: 3 GARBAGEGRINDER: - No LEACH AREA REQUIRED CAPACITY: 330 GPD SEPTIC TANK: 1500 GAL. USE 3 DRY WELLS SET 3' APART WITH BOTTOM LEACHING AREA: 277.9 SF 18" STONE ON THE SIDES, AND 2' STONE [(35.5' X 7.83')] ON THE ENDS, FOR A 35'-6" X 7'-10" X 2' DEEP LEACH AREA. 82 - - - - SIDE LEACHING AREA: 173.3 SF BENCH MARK --TOP & CENTER OF [2(7.83'+ 35.5') X 2' DEEP)] \ CONC. BOUND= 30.82 ASSIGNED DESIGN CAPACITY: 333 GPD 1-�O,fd 30,2, [(277.9 SF + 173.3 SF) X .74 GPD/SF] THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE. AAL AGENT APPROVAL DATE SITE PLAN FOR CLASBY FAMILY TRUST LOT 96, 18 SWIFT BROOK ROAD, SO. AUGUST 15, 2002 SCALE: YARMOUTH, MA 1 "=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 2002 BY R.J. CADILLAC 30.7 27.2 20.2 M M a Proposed S=1/4"/ft S=1/8"/ft min. 27'7 -Top Peastone Invert 28.25 1500 Gal. T Proposed 24"126" Invert 27.44 Invert 27.20 25.2 5 6" Stone or compact Proposed Proposed 1 Bottom I-_ 25'__I r- 27'-, 1 N I 1 I m 7' Bottom TH1=20.2 DESIGN DATA Fill A layer 10yr 2/1 loamy sand B layer 1Oyr 5/6 sandy loam C layer 2.5y 6/6 med. fine sand no water BEDROOMS: 3 GARBAGEGRINDER: - No LEACH AREA REQUIRED CAPACITY: 330 GPD SEPTIC TANK: 1500 GAL. USE 3 DRY WELLS SET 3' APART WITH BOTTOM LEACHING AREA: 277.9 SF 18" STONE ON THE SIDES, AND 2' STONE [(35.5' X 7.83')] ON THE ENDS, FOR A 35'-6" X 7'-10" X 2' DEEP LEACH AREA. 82 - - - - SIDE LEACHING AREA: 173.3 SF BENCH MARK --TOP & CENTER OF [2(7.83'+ 35.5') X 2' DEEP)] \ CONC. BOUND= 30.82 ASSIGNED DESIGN CAPACITY: 333 GPD 1-�O,fd 30,2, [(277.9 SF + 173.3 SF) X .74 GPD/SF] THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE. AAL AGENT APPROVAL DATE SITE PLAN FOR CLASBY FAMILY TRUST LOT 96, 18 SWIFT BROOK ROAD, SO. AUGUST 15, 2002 SCALE: YARMOUTH, MA 1 "=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 2002 BY R.J. CADILLAC 30.7 27.2 20.2 M M a CD C-,> a D M ^° PAGE 1 OF 1