Loading...
HomeMy WebLinkAbout4924 PlansFRAMING NOTES: 1. ALL FRAMING LUMBER SHALL BE HEM -FIR GRADE NO. 2 OR S.P.F. (SPRUCE — PINE — FIR) GRADE NO. 1 AND 2 OR APPROVED EQUAL (UNLESS OTHERWISE SPECIFIED) AND SHALL MEET THE REQUIREMENTS OF THE AMERICAN FOREST AND PAPER ASSOCIATION. THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 1050 P.S.I. THE MINIMUM ALLOWABLE COMPRESSION STRESS (Fc) SHALL BE 400 P.S.I. THE MINIMUM ALLOWABLE MODULUS OF ELASTICITY (E) SHA-L BE 1,400,000 P.S.I. 2. ALL LVL'S TO BE BOISE CASCADE OR I — LEVEL WEYERHAUSER VERSA — LAM 3100FB OR APPROVED EQUAL. THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 3100 P.S.I. ALL LVL POSTS TO BE VERSALAM 1.7 2650 FB, 1.8E PARALLAM PSL OR APPROVED EQUAL.NISTALL LVL'S IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 3. USE 3/4" TONGUE AND GROOVE STRUCTURAL GRADE FIR PLYWOOD FLOOR SHEATHING, 5/8" EXTERIOR STRUCTURAL GRADE FIR (C.D.X.) PLYWOOD ROOF SHEATHING, AND 1/2" EXTERIOR STRUCTURAL GRADE FIR (C.D.X.) AT WALLS. ALL JOINTS SHALL BE BLOCKED WITH LUMBER OR OTHER APPROVED SUPPORTS. 4. PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS AND/OR DOUBLE ALL JOISTS UNDER EACH PARTITION, 5. USE FULLY NAILED METAL CONNECTORS (TECO, SIMPSON, OR EQUAL), JOIST, OR BEAM HANGERS WHEN JOISTS OR BEAMS FRAME INTO OTHER JOISTS OR BEAMS. PROVIDE METAL POST CAPS AND BASES FOR ALL POSTS. 6. FOR LVL BEAMS OR HEADERS PROVIDE SOLID 4X4 LVL MINIMUM POST SUPPORTS FOR DOUBLES AND SOLID 4X6 OR 6X6 LVL MINIMUM POSTS FOR TRIPLE BEAMS OR HEADERS, OR AS OTHERWISE SPECIFIED ON THE PLAN. 7. ALL PLYWOOD FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING WOOD FRAMING MEMBERS USING AMERICAN PLYWOOD ASSOCIATION (A.P.A.) GLUED FLOOR SYSTEM. WOOD GLUE TO BE CONTECH, INC. PL400 SUBFLOOR CONSTRUCTION ADHESIVE, OR APPROVED EQUAL. 8. BUILT—UP BEAMS (3 PLY MAXIMUM) USING CONVENTIONAL FRAMING LUMBER SHALL BE FULLY SPIKED TOGETHER WITH 2-10D NAILS AT 12" O.C. LVL BEAMS (4 PLY MAXIMUM) TO BE THRU—BOLTED WITH 1/2 INCH DIAMETER THRU—BOLTS OR EQUIVALENT POWER SCREWS STAGGERED TOP AND BOTTOM AT 16 to O.C. OR AS OTHERWISE REQUIRED BY THE MANUFACTURER. 9. ALL MANUFACTURERED FLOOR I —JOISTS TO BE DESIGNED BY THE SUPPLIER/MANUFACTURER. SUBMIT SHOP DRAWINGS AND CALCULATIONS TO THE ENGINEER PRIOR TO FABRICATION. TYPICAL NOTES: 1.. STRUCTURAL ENGINEER OR ARCHITECT SHALL PERFORM FRAMING INSPECTION WHEN FRAMING IS COMPLETE AND PRIOR TO ENCLOSURE BY INTERIOR WALL PLASTER BOARD/FINISH. 2. CONTRACTOR SHALL SITE INSPECT ALL EXISTING VS. PROPOSED CONDITIONS PRIOR TO AND DURING CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DESCREPANCIES AND/OR CHANGES THAT MAY BE ENCOUNTERED. 3. ARCHITECT'S DRAWINGS DEMONSTRATE DESIGN INTENT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COMPLETE THE WORK IN A MANNER THAT ACHIEVES DESIGN INTENT. 4. THE CONTRACTOR IS RESPONSIBLE FOR THE PERFORMANCE OF THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND SHALL BE EXCLUSIVELY RESPONSIBLE FOR ITS CONSTRUCTION MEANS, METHODS, SEQUENCES, WARRANTIES, AND PROCEDURES, AND FOR CONSTRUCTION SAFETY. 6X6 POST r o I � , (0 N , � ; FLOOR PLAN SEE SHEET A.3 FOR PORTAL WALL FRAMING DETAILS 36'-0" BACKFIL� BACK ,SIDE OF REAR WALL 3 W/ 24 OF 1.5 ROUND STONE IN 24" MAX LIFTS ---------------------------------y ---- ------------------------------------------------------------------- ------ I ; i ' CV 10" ' i i N ; I ; i i N ; i ------------------ ------------------------------------ ; ; RETURN REINFORCED WALL ' —AROUND CORNER PER SITE CONDITIONS — GARAGE SLAB 5" 3000 PSI SLAB PITCH 1 /8" PER FOOT TOWARDS DOORS BACKFILL W/ CLEAN COMPACTED FILL DROP TOP OF WALL 12" AT DOOR OPENINGS PROVIDE ##5 PULL BARS IN COUNDAT(ON WALL TO TIE RETAINING WALLS IF NECESSARY 10" QIAM SONO—TUBE W/ 28 BIGFOOT FOOTING III ; 1 2 ; A. YA.1------------------------------------------------------------------------------------+------------------------------------ ----------------------- --------------------------------------------------------- I -----L------------------------- I ----------- --------------- A VA_. 2-, 16'-6" FOUNDATION PLAN CONTRACTOR SHALL STEP FOOTINGS PER EXISTING GRTADES TO MAINTAIN 48" MINIMUM COVERAGE DROP TOP OF WALL PER SITE CONDITONS Mr.% ,_r„ ARY POST D W/ I .---., (0 6X6 PT POST SEE DETAILS 8&9 ON SHEET A.2 FOR DETAILS ,_')„ I ),—1 n" FOUNDATION NOTES: 1. MAIN FOUNDATION WALLS TO BE 10" POURED CONC. W/ 2®#5 TOP & BOTTOM BARS. REST FOUNDATION ON 10"X20" STRIP FOOTING. PROVIDE 3®#5 HORIZ. BARS CONTINUOUS IN STRIP FOOTING W/ KEYWAY PROVIDE 5/8"X12" ANCHOR BOLTS 0 4'-0" O.C. MAX. 2. GARAGE SLAB TO BE 4" POURED CONC. ON COMPACTED FILL. CUT JOINTS ALONG WALLS AND BEAM COLUMN LINES. 3. CONTRACTOR SHALL ENSURE THAT ALL FOUNDATION WALLS MAINTAIN 4'-0" MINIMUM COVER. a r C h r, architects inferior designers builders 299 WHITE'S PATH SOUTH YARMOUTH, MASSACHUSETTS, 02664 fel (508) 362 - 8883 (508) 760 - 2800 fax (508) 760 - 5800 WWW.ERTARCHITECTS.COM NEW GARAGE 43 AUTUMN DRIVE PROJECT # 150412 2021 ERT ARCHITECTS, INC. THE DRAWINGS AND ALL OF THE IDEAS, ARRANGEMENTS, DESIGNS, AND PLANS INDICATED THEREON OR REPRESENTED THEREBY, ARE OWNED BY AND REMAIN THE PROPERTY OF ERT ARCHITECTS, INC. NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE, EXCEPT WITH SPECIFIC WRITTEN PERMISSION OF THE FIRM ERT ARCHITECTS, INC. THESE PLANS ARE NOT TO BE USED FOR PERMITTING OR CONSTRUCTION PURPOSES UNLESS STAMPED & SIGNED WITH AN ORIGINAL ARCHITECT'S STAMP AND SIGNATURE & MARKED AS "PERMIT SET" OR "CONSTRUCTION SET'. REGISTRATION REVISIONS DATE: REVISIONS: ISSUED FOR: DATE: I D 9 PROJECT TRUE ,SCALE: 1 /4"= V— 0" 0 1 2 4 8 UNLESS OTHERWISE NOTED. SHEET N0. - I I A., 1 TOTAL NUMBER OF SHEETS IN SET: THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS