Loading...
HomeMy WebLinkAbout22010994JR-eng912 =3x4 =2x4 =4x4 =4x4 =6x8 =4x4 =2x4 =3x4HUS26HUS26HUS26HUS26 8 17 18 7 19 20 6 51 2 4 15 16 3 T1 T1 B1 W3 W2W2W1 W1 3-00-13 3-00-13 3-00-13 12-00-00 2-11-03 8-11-03 2-11-03 6-00-00 2-12 1-02-12 2-12 11-00-00 1-00-00 1-00-00 1-00-00 12-00-00 4-09-04 6-00-00 4-09-04 10-09-046-105-00-10Scale = 1:51.4 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.11 Vert(LL)-0.02 7-8 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.46 Vert(CT)-0.03 6-7 >999 180 TCDL 10.0 Rep Stress Incr NO WB 0.20 Horz(CT)0.01 6 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 116 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 ocbracing. REACTIONS (size)6=5-08, (min. 1-09), 8=5-08, (min.1-08) Max Horiz 8=-206 (LC 6) Max Uplift 6=-355 (LC 11), 8=-351 (LC 10) Max Grav 6=1993 (LC 1), 8=1939 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-703/88, 2-15=-1691/323, 3-15=-1611/336, 3-16=-1611/336, 4-16=-1691/323, 4-5=-753/91 BOT CHORD 1-8=-32/515, 8-17=-282/1221, 17-18=-282/1221, 7-18=-282/1221, 7-19=-177/1230, 19-20=-177/1230, 6-20=-177/1230, 5-6=-34/555 WEBS 3-7=-239/1651, 4-7=-75/284, 2-7=-75/289,2-8=-1138/260, 4-6=-1090/255 NOTES 1)2-ply truss to be connected together with 10d(0.131"x3") nails as follows:Top chords connected as follows: 2x4 - 1 row at 9-00 oc.Bottom chords connected as follows: 2x6 - 2 rowsstaggered at 9-00 oc.Web connected as follows: 2x4 - 1 row at 9-00 oc. 2)All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOADCASE(S) section. Ply to ply connections have beenprovided to distribute only loads noted as (F) or (B),unless otherwise indicated. 3)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for a 10.0 psf bottomchord live load nonconcurrent with any other live loads. 7)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 8)One RT7A MiTek connectors recommended to connecttruss to bearing walls due to UPLIFT at jt(s) 8 and 6.This connection is for uplift only and does not consider lateral forces. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Use MiTek HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 3-1-4 from the left end to 9-1-4 to connect truss(es) to front face of bottom chord. 11)Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard 1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-3=-90, 3-5=-90, 9-12=-20 Concentrated Loads (lb) Vert: 17=-653, 18=-653, 19=-653, 20=-653 Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA G01 Common Girder 1 222010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:p9YspFo6f8W6iFalSlxMBjzvmoA-pY7brSeye9ME0NdqdqJNRl8BgJprVkJ60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =5x16 =5x6 =2x4 =4x8 =10x12 =2x4 =5x6 =5x16 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 19 20 21 8 22 23 24 1 7 2 6 53 17 18 4 T1 T1 B1 W2 W1 W1 HW1 HW1 3-03-01 3-03-01 3-03-00 14-00-00 3-08-15 7-00-00 3-09-00 10-09-00 7-00-00 14-00-00 7-00-00 7-00-001-03-106-06-10Scale = 1:51.9 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.37 Vert(LL)-0.08 8-15 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.87 Vert(CT)-0.12 8-15 >999 180 TCDL 10.0 Rep Stress Incr NO WB 0.65 Horz(CT)0.01 7 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 185 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP No.1 WEBS 2x4 SPF No.2 SLIDER Left 2x8 SP No.1 -- 1-11-12, Right 2x8 SP No.1 -- 1-11-12 BRACINGTOP CHORD Structural wood sheathing directly applied or5-3-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (size)1=5-08, (min. 3-00), 7=5-08, (min. 3-01) Max Horiz 1=240 (LC 9) Max Uplift 1=-1850 (LC 10), 7=-1898 (LC 11) Max Grav 1=5072 (LC 1), 7=5202 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-2=-3882/1371, 2-3=-4955/1851, 3-17=-4809/1839, 4-17=-4747/1854, 4-18=-4747/1854, 5-18=-4811/1839, 5-6=-4960/1852, 6-7=-3467/1279 BOT CHORD 1-19=-1524/3948, 19-20=-1524/3948, 20-21=-1524/3948, 8-21=-1524/3948, 8-22=-1397/3880, 22-23=-1397/3880,23-24=-1397/3880, 7-24=-1397/3880WEBS4-8=-1996/5280, 3-8=-153/350, 5-8=-169/344 NOTES 1)2-ply truss to be connected together with 10d(0.131"x3") nails as follows:Top chords connected as follows: 2x4 - 1 row at 9-00 oc.Bottom chords connected as follows: 2x8 - 2 rowsstaggered at 7-00 oc. Web connected as follows: 2x4 - 1 row at 9-00 oc. 2)All loads are considered equally applied to all plies,except if noted as front (F) or back (B) face in the LOADCASE(S) section. Ply to ply connections have beenprovided to distribute only loads noted as (F) or (B),unless otherwise indicated. 3)Wind: ASCE 7-10; Vult=140mph (3-second gust)Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for a 10.0 psf bottomchord live load nonconcurrent with any other live loads. 7)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 8)One LUGT2 MiTek connectors recommended to connecttruss to bearing walls due to UPLIFT at jt(s) 1 and 7.This connection is for uplift only and does not consider lateral forces. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Use MiTek HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 2-1-4 from the left end to 12-1-4 to connect truss(es) to back face of bottom chord. 11)Fill all nail holes where hanger is in contact with lumber. 12)Minimum of a double stud required directly beneath thistruss to attach LUGT2 tiedown. LOAD CASE(S) Standard 1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-4=-90, 4-7=-90, 9-13=-20 Concentrated Loads (lb) Vert: 19=-1456, 20=-1456, 21=-1456, 22=-1456, 23=-1456, 24=-1456 Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA G05 Common Girder 1 222010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:ikNfM3Sci2RIoiHKAoQFwKzvmnJ-Hlh_3nfaPTU5eXC1AYqc_zhILj3fE4YGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x4 =2x4 =2x4 =4x10 =6x6 =3x6 8 7 65 1 12 2 1314 34 T1 W4 B1 W3W1W2 HW1 5-03-09 5-03-09 6-08-07 12-00-00 2-08 12-00-00 2-12 1-02-12 1-00-00 1-00-00 4-00-13 5-03-09 6-05-15 11-09-089-06-106-109-06-10Scale = 1:75.4 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.84 Vert(LL)-0.05 6-7 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.31 Vert(CT)-0.11 6-7 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.72 Horz(CT)-0.01 6 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 61 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or5-3-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 3-6 REACTIONS (size)6= Mechanical, (min. 1-08), 8=5-08, (min. 1-08) Max Horiz 8=642 (LC 12) Max Uplift 6=-564 (LC 12), 8=-52 (LC 12) Max Grav 6=750 (LC 18), 8=740 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-12=-314/341, 2-13=-276/116, 3-6=-383/297 BOT CHORD 7-8=-469/605, 6-7=-469/606 WEBS 2-6=-695/539, 2-8=-715/0, 2-7=0/252 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-0-0, Interior (1) 3-0-0 to 7-9-1, Exterior (2) 7-9-1 to 12-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 6)Refer to girder(s) for truss to truss connections. 7)Provide mechanical connection (by others) of truss tobearing plate capable of withstanding 564 lb uplift atjoint 6. 8)One RT7A MiTek connectors recommended to connecttruss to bearing walls due to UPLIFT at jt(s) 8. Thisconnection is for uplift only and does not consider lateralforces. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)WARNING: The following hangers are manually appliedbut fail due to geometric considerations: One RT7A on front face at 1-0-13 from the left end. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA M04 Jack-Closed 2 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:rNpZyp72jfmwFzh5sI4w1Ezvmy3-pY7brSeye9ME0NdqdqJNRl8?GJsBVcB60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x4 =2x4 =3x6 =6x6 =3x6 7 6 5 1 11 2 1213 34 T1 W3 B1 W2W1 HW1 5-03-09 5-03-09 6-08-07 12-00-00 2-08 12-00-00 5-03-09 5-03-09 6-05-15 11-09-089-06-106-109-06-10Scale = 1:63.8 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.84 Vert(LL)-0.05 6-7 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.33 Vert(CT)-0.10 6-7 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.80 Horz(CT)-0.01 6 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 55 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or5-7-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-2-2 oc bracing. WEBS 1 Row at midpt 3-6 REACTIONS (size)1= Mechanical, (min. 1-08), 6= Mechanical, (min. 1-08) Max Horiz 1=642 (LC 12) Max Uplift 1=-47 (LC 12), 6=-569 (LC 12) Max Grav 1=673 (LC 18), 6=817 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-11=-842/61, 2-11=-591/0, 2-12=-275/114, 3-6=-382/294 BOT CHORD 1-7=-651/673, 6-7=-485/673 WEBS 2-6=-778/561, 2-7=0/271 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-0-0, Interior (1) 3-0-0 to 7-9-1, Exterior (2) 7-9-1 to 12-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members.6)All bearings are assumed to be User Defined crushingcapacity of 425 psi. 7)Refer to girder(s) for truss to truss connections. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 1 and 569 lb uplift at joint 6. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA M04A Jack-Closed 4 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:kh5wxobunKYXppbP5HlqaFzvmxT-pY7brSeye9ME0NdqdqJNRl8?GJrtVbx60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 14 13 12 11 10 9 1 2 3 4 5 6 78 T1 W1 B1 ST5 ST4 ST3 ST2 ST1 HW1 12-00-00 2-08 12-00-00 11-09-08 11-09-089-06-106-109-06-10Scale = 1:58.8 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.17 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.13 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.30 Horiz(TL)-0.02 8 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 67 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACINGTOP CHORD Structural wood sheathing directly applied or6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-9 REACTIONS All bearings 12-00-00. (lb) -Max Horiz 1=644 (LC 12), 15=644 (LC 12) Max Uplift All uplift 100 (lb) or less at joint(s) 8, 9 except 1=-143 (LC 10), 10=-187 (LC 12), 11=-183 (LC 12),12=-193 (LC 12), 13=-148 (LC 12),14=-322 (LC 12), 15=-143 (LC 10) Max Grav All reactions 250 (lb) or less at joint (s) 8, 9, 12, 13 except 1=501 (LC 12), 10=324 (LC 18), 11=265 (LC 18), 14=309 (LC 21), 15=501 (LC 12) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-767/632, 2-3=-602/493, 3-4=-476/392,4-5=-340/282 BOT CHORD 1-14=-469/383 WEBS 6-10=-283/210, 2-14=-272/259 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zoneand C-C Corner (3) 0-0-0 to 3-0-0, Exterior (2) 3-0-0 to12-0-0 zone; cantilever left and right exposed ;C-C formembers and forces & MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 2x4 MT20 unless otherwise indicated. 6)Gable requires continuous bottom chord bearing. 7)Gable studs spaced at 2-0-0 oc. 8)This truss has been designed for a 10.0 psf bottomchord live load nonconcurrent with any other live loads. 9)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection (by others) of truss tobearing plate capable of withstanding 100 lb uplift atjoint(s) 8, 9 except (jt=lb) 1=143, 10=187, 11=183,12=192, 13=148, 14=322, 1=143. 11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA M04GE Monopitch Supported Gable 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:zQ8KqtiXf5hFOBn77gQxR9zvmxK-pY7brSeye9ME0NdqdqJNRl8AjJu0Vjl60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 =4x4 =3x4 =3x4 91 15 14 13 12 11 10 82 3 7 23 28 4 624272526 5 T1 T1 B1 B2 ST3 ST2 ST1 ST2 ST1 8-00 8-00 8-00 21-01-11 9-10-13 10-06-13 9-10-13 20-05-11 19-09-117-11-064-101-10-1-107-09-127-09-12Scale = 1:53.3 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.32 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.16 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.27 Horz(CT)0.01 10 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 74 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 ocbracing. REACTIONS All bearings 19-09-11. (lb) -Max Horiz 2=355 (LC 11), 16=355 (LC 11) Max Uplift All uplift 100 (lb) or less at joint(s)8, 19 except 2=-119 (LC 8),10=-307 (LC 13), 12=-408 (LC 13),14=-408 (LC 12), 15=-309 (LC 12),16=-119 (LC 8) Max Grav All reactions 250 (lb) or less at joint (s) 2, 8, 16, 19 except 10=393 (LC 23), 12=598 (LC 23), 13=489 (LC 25), 14=598 (LC 22), 15=395 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-350/274, 3-23=-273/178,4-24=-269/282, 24-25=-262/283, 5-25=-243/304, 5-26=-243/272, 26-27=-262/252, 6-27=-269/251, 7-8=-271/181 BOT CHORD 2-15=-132/259, 14-15=-132/259, 13-14=-132/259, 12-13=-132/259, 11-12=-132/259, 10-11=-132/259, 8-10=-132/259WEBS5-13=-275/19, 4-14=-475/450,3-15=-362/340, 6-12=-475/449, 7-10=-362/339 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust)Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-3-1 to 3-3-1, Interior (1) 3-3-1 to 7-7-3, Exterior (2) 7-7-3 to 13-7-3, Interior (1) 13-7-3 to 17-11-4, Exterior (2) 17-11-4 to 20-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp D; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof liveload of 16.0 psf or 2.00 times flat roof load of 35.0 psf onoverhangs non-concurrent with other live loads. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 4-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 8 except (jt=lb) 2=119, 14=408, 15=308, 12=408, 10=306, 2=119. 12)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. 13)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA PB01 Piggyback 8 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:b?WA_ffP_NKQWHDuKC3ccKzvnAt-Hlh_3nfaPTU5eXC1AYqc_zhJ8jEmEATGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 =3x6 =3x8 =4x4 =3x6 =3x4 =3x4 111 17 16 15 14 13 12 102 3 927321918 84 5 728312930 6 T1 T1 B1 B2 W2 W1W1 ST2 ST3 ST1 ST2 ST3 ST1 8-00 21-01-11 8-00 8-00 4-10-05 10-06-13 4-10-05 15-05-03 5-00-08 5-08-08 5-00-08 20-05-11 9-10-13 10-06-13 9-10-13 20-05-117-11-064-101-10-1-107-09-127-09-12Scale = 1:54.7 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.31 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.10 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.30 Horz(CT)0.01 10 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 87 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS All bearings 19-09-11. (lb) -Max Horiz 2=355 (LC 11), 20=355 (LC 11) Max Uplift All uplift 100 (lb) or less at joint(s) 10, 15, 24 except 2=-109 (LC 8), 12=-255 (LC 13), 14=-277 (LC 13), 16=-289 (LC 12), 17=-261 (LC 12), 20=-109 (LC 8) Max Grav All reactions 250 (lb) or less at joint(s) 2, 10, 20, 24 except 12=360 (LC23), 14=523 (LC 20), 15=481 (LC1), 16=523 (LC 19), 17=367 (LC22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-268/226, 3-27=-279/161, 6-29=-181/252 WEBS 6-15=-306/24, 5-18=-444/339,16-18=-440/331, 3-17=-303/284,7-19=-444/329, 14-19=-440/319,9-12=-303/279 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-3-1 to 3-3-1, Interior (1) 3-3-1 to 7-7-3, Exterior (2) 7-7-3 to 13-7-3, Interior (1) 13-7-3 to 17-11-4, Exterior (2) 17-11-4 to 20-11-4 zone; cantilever left and right exposed ; end vertical left and rightexposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate gripDOL=1.60 2) Truss designed for wind loads in the plane of the trussonly. For studs exposed to wind (normal to the face),see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp D; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for thisdesign. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 4-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottomchord and any other members.11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 15, 10, 10 except (jt=lb) 2=108, 16=289, 17=261, 14=276, 12=254, 2=108. 12)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA PB01GE Piggyback 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:6TP4cSlU77xt7h7EqQ2jYhzvn?8-Hlh_3nfaPTU5eXC1AYqc_zhJHjFhEA?GFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 =4x4 =3x412111098 71 2 6 3 5 4 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 6-00-00 6-00-00 6-00-00 12-00-00 1-00-00 1-00-00 11-00-00 12-00-006-105-00-10Scale = 1:40.2 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.13 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.14 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.12 Horiz(TL)0.00 8 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 47 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. REACTIONS All bearings 10-00-00. (lb) -Max Horiz 12=-206 (LC 8) Max Uplift All uplift 100 (lb) or less at joint(s)except 8=-190 (LC 12), 9=-244 (LC13), 11=-246 (LC 12), 12=-194 (LC13) Max Grav All reactions 250 (lb) or less at joint (s) except 8=315 (LC 19), 9=305 (LC 22), 10=343 (LC 1), 11=331 (LC 21), 12=315 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. WEBS 4-10=-294/21, 3-11=-252/236, 2-12=-235/269 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Corner (3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 2x4 MT20 unless otherwise indicated. 6)Gable studs spaced at 2-0-0 oc. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 246 lb uplift at joint 11, 193 lb uplift at joint 12, 244 lb uplift at joint 9 and 190 lb uplift at joint 8. 10)Non Standard bearing condition. Review required. 11)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T01GE Common Supported Gable 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:84MLGGFl3wMsI6jnFdjUmezvmwd-pY7brSeye9ME0NdqdqJNRl8AMJurVma60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x6 =4x10 =4x8 =5x12 =4x6 =4x6 =3x4 =3x4 =8x8 =6x10 =4x4 =5x6 =4x4 =8x8 =5x8 =3x4 =7x16 =8x8 =5x12 =4x6 =4x6 =8x8 =6x6 =4x8 =2x4 =4x6 One RT7A 1 26 25 24 19 1817 16 15 14 132233940224142214320 31 38 3 123732 114 5 10783435369633 T2 T1 T3 T4 T2 T1 B1 B6 B7 B2 B3 B4 B5 W5 W11 W10 W12 W13 W14W3 W4 W1 W16W15W2 W6 W9W7W8W8 1-05-08 1-05-08 1-04-08 50-10-00 3-02-07 36-00-03 3-00-05 14-09-13 4-09-15 6-03-07 5-06-01 11-09-08 5-07-06 49-05-08 8-11-09 32-09-12 9-00-05 23-10-03 7-10-00 43-10-02 1-15 27-11-04 4-08 49-10-00 5-08 1-05-08 1-00-00 1-00-00 1-00-00 50-10-00 10-15 36-11-00 3-05-01 36-00-01 4-09-15 6-03-07 4-07-12 32-07-00 5-07-13 11-11-04 5-10-04 42-09-04 6-08-04 49-05-08 7-10-03 27-09-05 7-11-14 19-11-026-103-00-0011-08-0042-00-00 Scale = 1:90.2 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.47 Vert(LL)-0.17 22-23 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.32 Vert(CT)-0.28 22-23 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.86 Horz(CT)0.22 16 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 350 lb FT = 20% LUMBER TOP CHORD 2x6 SPF 2100F 1.8E BOT CHORD 2x6 SPF 2100F 1.8E *Except* 24-5:2x4 SPF No.2, 9-19:2x6 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-26,13-15:2x6 SPF No.2 BRACINGTOP CHORD Structural wood sheathing directly applied or4-11-7 oc purlins, except 2-0-0 oc purlins (5-1-8 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. Except: 1 Row at midpt 9-20 WEBS 1 Row at midpt 10-20, 12-18, 12-16, 6-23, 8-22, 8-21 WEBS 2 Rows at 1/3 pts 10-18 REACTIONS (size)15=4-08, (min. 1-08), 16=5-08,(min. 4-02), 26=5-08, (min. 3-01) Max Horiz 26=-513 (LC 8) Max Uplift 15=-244 (LC 18), 16=-784 (LC 9),26=-782 (LC 12) Max Grav 15=331 (LC 11), 16=3225 (LC 1), 26=2395 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-300/82, 2-31=-2659/1106,3-31=-2425/1132, 3-32=-3798/1572,4-32=-3636/1586, 4-5=-3618/1601,5-6=-3648/1820, 6-33=-2653/1365,7-33=-2653/1365, 7-8=-2653/1365, 8-34=-2328/1262, 34-35=-2328/1262, 35-36=-2328/1262, 9-36=-2328/1262, 9-10=-1868/1072, 10-11=-1161/802, 11-37=-1363/770, 12-37=-1404/754, 12-38=-351/713, 13-38=-381/656 BOT CHORD 1-26=-73/292, 25-26=-560/622, 5-23=-418/410, 23-39=-1108/2464, 39-40=-1108/2464, 22-40=-1108/2464, 22-41=-1211/2714, 41-42=-1211/2714, 21-42=-1211/2714, 21-43=-761/1921, 20-43=-759/1923, 9-20=-1370/797, 17-18=-1006/534, 16-17=-1006/534 WEBS 3-23=-394/987, 18-20=-393/1200,10-20=-1170/2542, 10-18=-2045/845,12-18=-909/2308, 12-16=-3050/1390, 3-25=-1443/680, 23-25=-1049/2226, 2-26=-2090/1040, 13-15=-225/340, 13-16=-432/196, 2-25=-647/1768, 6-23=-823/1491, 9-21=-425/1262, 6-22=-405/694, 8-22=-452/490, 8-21=-1140/526 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 5-1-0, Interior (1) 5-1-0 to 7-8-8, Exterior (2) 7-8-8 to 22-1-0, Interior (1) 22-1-0 to 28-9-0, Exterior (2) 28-9-0 to 43-1-8, Interior (1) 43-1-8 to 45-9-0, Exterior (2) 45-9-0 to 50-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10, W left=25-5-0, W right =25-5-0 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottomchord and any other members, with BCDL = 10.0psf. 6)Two RT7A MiTek connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 16 and 26. This connection is for uplift only and does not consider lateral forces. 7)One RT7A MiTek connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 15. This connection is for uplift only and does not consider lateral forces. 8)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. 9)Graphical purlin representation does not depict the sizeor the orientation of the purlin along the top and/orbottom chord. 10)Double installations of RT7A require the two hurricaneties to be installed on opposite sides of top plate toavoid nail interference in single ply truss. 11)The loading on this truss has been modified to reflect the roof profile, the ridgeline is located 25-5-0 from joint 1 and has a slope of 9.000 on the left and -9.000 on the right. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T02 Piggyback Base 2 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:onrII_dmnsMw4Z5YR6O8qIzvn0a-pY7brSeye9ME0NdqdqJNRl852Js2Va?60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x6 =4x6 =3x4 =3x4 =3x4 =4x6 =8x8 =8x8 =3x4 =3x4 =3x4 =6x6 =4x6 =4x6 =4x6 1 6362 61 60 59 58 57 44 43 4241 40 39 38 37 36 35 34 33 3223713156 55 54 53 52 51 50 49 48 47 46 454 7030 5 29 6 282778269 25 10 24111213146815161718691920212223 T2 T1 T3 T4 T2 T1 B1 B6 B7 B2 B3 B4 B5 W1 W1 ST8ST7 ST6ST6ST6ST6ST6ST6ST6ST6ST6ST5 ST5 ST4 ST3 ST2 ST1 ST9 ST10 ST11 ST12 ST13 ST14 1-01-12 1-01-12 1-01-12 50-10-00 3-02-11 36-00-03 3-00-13 14-09-13 10-07-04 11-09-00 13-08-01 49-08-04 17-11-11 32-09-08 1-12 49-10-00 1-00-00 50-10-00 1-01-12 1-01-12 4-03-04 36-11-00 4-09-00 32-07-12 10-09-00 11-10-12 12-09-04 49-08-04 16-00-00 27-10-126-103-00-0011-08-00Scale = 1:85.1 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.10 Vert(LL)0.00 21 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.12 Vert(CT)0.00 21 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.40 Horz(CT)0.05 39 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 392 lb FT = 20% LUMBER TOP CHORD 2x6 SPF 2100F 1.8E BOT CHORD 2x6 SPF 2100F 1.8E *Except* 57-9,21-44:2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACINGTOP CHORD Structural wood sheathing directly applied or6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 11-23. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing, Except:10-0-0 oc bracing: 56-57,44-45. T-Brace:2x4 SPF No.2 - 21-45 WEBS T-Brace:2x4 SPF No.2 - 24-42, 22-43, 25-40 Fasten (2X) T and I braces to narrow edgeof web with 10d (0.131"x3") nails, 6ino.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS All bearings 41-06-08. except 37=7-03-08, 36=7-03-08, 35=7-03-08, 34=7-03-08 (lb) -Max Horiz 63=513 (LC 9) Max Uplift All uplift 100 (lb) or less at joint(s) 42, 43, 44, 46, 57 except 34=-174 (LC 13), 35=-154 (LC 13), 36=-190 (LC 13), 37=-182 (LC 13), 38=-186 (LC 13), 39=-210 (LC 13), 40=-106 (LC 13), 45=-116 (LC 8), 47=-105(LC 8), 48=-106 (LC 8), 49=-105(LC 9), 50=-101 (LC 9), 51=-103(LC 8), 52=-114 (LC 8), 53=-121(LC 8), 54=-119 (LC 11), 55=-132(LC 9), 56=-233 (LC 12), 58=-147(LC 12), 59=-186 (LC 12), 60=-190 (LC 12), 61=-168 (LC 12), 62=-640 (LC 9), 63=-944 (LC 8) Max Grav All reactions 250 (lb) or less at joint(s) 44, 45, 57 except 34=253 (LC19), 35=293 (LC 40), 36=382 (LC 30), 37=365 (LC 30), 38=367 (LC 30), 39=373 (LC 30), 40=374 (LC 30), 42=365 (LC 44), 43=257 (LC 29), 46=265 (LC 29), 47=365 (LC 29), 48=372 (LC 29), 49=366 (LC 29), 50=360 (LC 29), 51=367 (LC 29), 52=377 (LC 29), 53=375 (LC 29), 54=390 (LC 43), 55=453 (LC 44), 56=371 (LC 30), 58=305 (LC 30), 59=374 (LC 30), 60=366 (LC 30), 61=384 (LC 30), 62=694 (LC 10), 63=963 (LC 11) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-576/583, 2-3=-711/723, 3-4=-579/610,4-5=-540/602, 5-6=-503/679, 6-7=-474/750, 7-8=-455/756, 8-9=-554/817, 9-10=-683/913, 10-11=-614/772, 11-12=-607/772, 12-13=-607/772, 13-14=-607/772, 14-68=-607/772, 15-68=-607/772, 15-16=-608/773, 16-17=-608/773, 17-18=-608/773, 18-69=-609/773, 19-69=-609/773, 19-20=-609/773, 20-21=-609/773, 21-22=-609/774, 22-23=-609/774, 23-24=-553/688, 24-25=-691/870, 25-26=-625/783, 26-27=-495/634, 27-28=-507/623, 28-29=-401/499, 29-30=-297/365 BOT CHORD 1-63=-499/504, 9-56=-354/241 WEBS 24-42=-321/194, 19-47=-322/129, 18-48=-331/129, 17-49=-328/126, 16-50=-319/123, 15-51=-326/125, 14-52=-337/140, 13-53=-334/147, 12-54=-356/161, 10-55=-388/158, 8-58=-268/162, 6-59=-333/208, 5-60=-328/203, 4-61=-336/211, 3-62=-338/266, 25-40=-334/124, 26-39=-333/230, 28-38=-326/205, 29-37=-326/202, 30-36=-335/207, 31-35=-272/187 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust)Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Corner (3) 0-0-0 to 5-1-0, Exterior (2) 5-1-0 to 9-9-12, Corner (3) 9-9-12 to 20-0-3, Exterior (2) 20-0-3 to 30-10-4, Corner (3) 30-10-4 to 41-0-4, Exterior (2) 41-0-4 to 45-9-0, Corner (3) 45-9-0 to 50-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 6)Provide adequate drainage to prevent water ponding. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable studs spaced at 2-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T02GE Piggyback Base Supported Gable 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:2sWr17mkekCaM?Hdxr4Bd6zvn?6-Hlh_3nfaPTU5eXC1AYqc_zhMZjFOE8RGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. Continued on page 2 02/14/2022 10)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottomchord and any other members. 11)Bearings are assumed to be: Joint 63 SPF 2100F 1.8E crushing capacity of 525 psi. 12)Bearing at joint(s) 56, 45 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 13)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 57, 44, 42, 43, 46 except (jt=lb) 56=232, 47=105, 48=105, 49=105, 50=100, 51=103, 52=113, 53=120, 54=118, 55=131, 58=146, 59=185, 60=189, 61=168, 62=639, 40=105, 39=209, 38=186, 37=181, 36=189,35=154, 45=116, 63=943, 34=173. 14)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. 15)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16)Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T02GE Piggyback Base Supported Gable 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 2 ID:2sWr17mkekCaM?Hdxr4Bd6zvn?6-Hlh_3nfaPTU5eXC1AYqc_zhMZjFOE8RGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x6 =4x10 =4x8 =5x10 =4x6 =4x6 =3x4 =3x4 =8x8 =6x10 =4x4 =4x6 =5x10 =8x8 =3x4 =4x4 =8x12 =6x6 =10x12 =5x6 =6x8 =4x6 =8x8 =2x4 =12x12 =4x6 Two RT16A 1 27 26 25 18 45 46 17 16 15 14224404123424322 21 32 39 3 133833 124 5 20 19 44 11 10783536379634 T2 T1 T3 T4 T2 T1 B1 B8 B2 B3 B4 B5 B6 B7 W5 W9 W15 W11 W3 W4 W6 W7 W8 W8 W10 W13 W14 W17W16W1W2 W12 1-05-08 1-05-08 1-04-08 50-10-00 3-03-07 36-00-03 2-06-00 43-10-02 3-00-05 14-09-13 4-09-15 6-03-07 5-04-00 41-04-02 5-06-01 11-09-08 5-07-06 49-05-08 8-07-06 32-08-12 9-03-09 24-01-06 4-08 49-10-00 5-08 1-05-08 1-00-00 1-00-00 1-00-00 50-10-00 4-09-15 6-03-07 5-01-03 32-10-08 5-07-13 11-11-04 6-06-04 42-09-04 6-08-04 49-05-08 7-10-03 27-09-05 7-11-14 19-11-02 3-04-08 36-03-0011-08-006-103-00-005-11-028-11-028-11-028-11-022-08-1411-08-003-00-003-00-005-11-028-11-0242-00-00 Scale = 1:90.4 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.54 Vert(LL)-0.21 21 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.29 Vert(CT)-0.32 21 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.99 Horz(CT)0.31 17 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 358 lb FT = 20% LUMBER TOP CHORD 2x6 SPF 2100F 1.8E BOT CHORD 2x6 SPF 2100F 1.8E *Except* 25-5,21-9:2x4 SPF No.2, 19-18:2x6 SPF No.2 WEBS 2x4 SPF No.2 *Except* 11-17:2x4 SPF 2100F 1.8E, 14-16,2-27:2x6 SPF No.2 BRACINGTOP CHORD Structural wood sheathing directly applied or5-2-12 oc purlins, except 2-0-0 oc purlins (4-3-6 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. WEBS 1 Row at midpt 8-20, 6-24, 8-23, 8-22, 14-17 WEBS 2 Rows at 1/3 pts 11-17 REACTIONS (size)16=4-08, (min. 1-08), 17=5-08, (req. 7-07), 27=5-08, (min. 2-13) Max Horiz 27=-513 (LC 10) Max Uplift 16=-1415 (LC 24), 17=-1310 (LC 9), 27=-772 (LC 12) Max Grav 16=766 (LC 9), 17=4758 (LC 1), 27=2219 (LC 18) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-2=-271/85, 2-32=-2437/1073, 3-32=-2202/1088, 3-33=-3415/1497, 4-33=-3253/1512, 4-5=-3235/1526, 5-6=-3261/1743, 6-34=-2253/1285, 7-34=-2253/1285, 7-8=-2253/1285,8-35=-3474/1514, 35-36=-3474/1514,36-37=-3474/1514, 9-37=-3474/1514,9-10=-3389/1484, 10-11=-1145/464,11-12=-961/2549, 12-38=-964/2322,13-38=-974/2311, 13-39=-962/2483,14-39=-985/2292, 14-15=-217/400 BOT CHORD 1-27=-75/268, 26-27=-550/598,5-24=-418/408, 24-40=-985/2179,40-41=-985/2179, 23-41=-985/2179, 23-42=-999/2221, 42-43=-999/2221, 22-43=-999/2221, 9-20=-889/370, 19-20=-452/1280, 19-44=-303/1060, 11-44=-303/1062, 18-19=-1272/676, 18-45=-330/164, 45-46=-330/164, 17-46=-330/164, 16-17=-278/189, 15-16=-278/189 WEBS 3-24=-333/846, 8-20=-988/2401, 13-17=-565/491, 10-20=-1337/2856, 3-26=-1307/622, 24-26=-965/2032, 6-24=-818/1437, 6-23=-354/419, 8-23=-199/461, 8-22=-1811/906, 20-22=-965/2285, 11-18=-653/1316, 11-17=-4073/1434, 14-16=-628/1274, 14-17=-1622/568, 2-27=-1935/1009, 2-26=-617/1612, 10-19=-1221/671 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 5-1-0, Interior (1) 5-1-0 to7-8-8, Exterior (2) 7-8-8 to 22-1-0, Interior (1) 22-1-0 to28-9-0, Exterior (2) 28-9-0 to 43-1-8, Interior (1) 43-1-8to 45-9-0, Exterior (2) 45-9-0 to 50-10-0 zone; cantileverleft and right exposed ; end vertical left and rightexposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp D; Partially Exp.; Ct=1.10, W left =25-5-0, W right =25-5-0 3)Unbalanced snow loads have been considered for thisdesign. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6)WARNING: Required bearing size at joint(s) 17 greater than input bearing size. 7)Bearings are assumed to be: , Joint 17 User Definedcrushing capacity of 425 psi, Joint 17 SPF No.2crushing capacity of 425 psi, Joint 16 User Defined crushing capacity of 425 psi, Joint 16 SPF No.2 crushing capacity of 425 psi. 8)Two RT16A MiTek connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 17 and 16. This connection is for uplift only and does not consider lateral forces.9)Two RT7A MiTek connectors recommended to connecttruss to bearing walls due to UPLIFT at jt(s) 27. Thisconnection is for uplift only and does not consider lateral forces. 10)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12)This truss has large uplift reaction(s) from gravity load case(s). Proper connection is required to secure truss against upward movement at the bearings. Building designer must provide for uplift reactions indicated. 13)Double installations of RT16A require installation on both interior and exterior sides. 14)Double installations of RT7A require the two hurricaneties to be installed on opposite sides of top plate toavoid nail interference in single ply truss. Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T03 Piggyback Base 6 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:Y2wnVm7o3TCVfpd0QfMvSSzvnGj-pY7brSeye9ME0NdqdqJNRl84xJsWVYz60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. Continued on page 2 02/14/2022 15)The loading on this truss has been modified to reflect the roof profile, the ridgeline is located 25-5-0 from joint1 and has a slope of 9.000 on the left and -9.000 on theright. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T03 Piggyback Base 6 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 2 ID:Y2wnVm7o3TCVfpd0QfMvSSzvnGj-pY7brSeye9ME0NdqdqJNRl84xJsWVYz60q8pB6zlI3c This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x4 =3x6 =3x6 =4x8 =5x6 =3x6 =3x6 =4x4 8 7 6 1 5 2 4 15 18 16 17 3 T1 T1 B1 W3 W1 W2 W1W2HW1HW1 1-02-12 1-02-12 1-02-12 16-00-00 6-09-04 14-09-04 6-09-04 8-00-00 2-12 1-02-12 2-12 15-00-00 1-00-00 1-00-00 1-00-00 16-00-00 6-09-04 14-09-04 6-09-04 8-00-006-106-06-1014-00-00 Scale = 1:59.7 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.80 Vert(LL)-0.03 7-8 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.33 Vert(CT)-0.07 7-8 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.17 Horz(CT)-0.01 6 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 66 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 Right: 2x4 SPF No.2 BRACINGTOP CHORD Structural wood sheathing directly applied or5-9-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 8-10-3 oc bracing: 7-8. REACTIONS (size)6=5-08, (min. 1-08), 8=5-08, (min. 1-08) Max Horiz 8=275 (LC 9) Max Uplift 6=-317 (LC 13), 8=-317 (LC 12) Max Grav 6=880 (LC 1), 8=880 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-2=-260/283, 2-15=-743/262, 15-16=-551/280, 3-16=-546/299, 3-17=-546/299, 17-18=-551/280, 4-18=-743/263 BOT CHORD 1-8=-251/337, 7-8=-436/543, 6-7=-256/342,5-6=-256/342 WEBS 2-8=-871/612, 2-7=-203/360, 4-6=-871/612, 4-7=-211/366 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-0-0, Interior (1) 3-0-0 to 5-0-0, Exterior (2) 5-0-0 to 11-0-0, Interior (1) 11-0-0 to 13-0-0, Exterior (2) 13-0-0 to 16-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate gripDOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottomchord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 6)One RT7A MiTek connectors recommended to connecttruss to bearing walls due to UPLIFT at jt(s) 8 and 6.This connection is for uplift only and does not considerlateral forces. 7)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T05 Common 7 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:UljpqgdmMeVHG_YP5jEwaTzvmsG-Hlh_3nfaPTU5eXC1AYqc_zhBdjB5EC1GFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 =4x4 =3x416151413121110 1 9 2 8 3 7 23 24 4 6 5 T1 T1 B1 ST4 ST3 ST2 ST1 ST3 ST2 ST1 8-00-00 8-00-00 8-00-00 16-00-00 1-00-00 1-00-00 15-00-00 16-00-006-106-06-10Scale = 1:46.4 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.14 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.18 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.22 Horiz(TL)0.00 11 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 69 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. REACTIONS All bearings 14-00-00. (lb) -Max Horiz 16=275 (LC 9) Max Uplift All uplift 100 (lb) or less at joint(s)except 10=-222 (LC 12), 11=-279(LC 13), 12=-163 (LC 13), 14=-162(LC 12), 15=-284 (LC 12), 16=-227(LC 13) Max Grav All reactions 250 (lb) or less at joint (s) except 10=329 (LC 21), 11=319 (LC 22), 12=310 (LC 19), 13=372 (LC 24), 14=310 (LC 18), 15=324 (LC 21), 16=335 (LC 22) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-243/349, 5-6=-243/349 WEBS 5-13=-334/129, 4-14=-261/195, 6-12=-261/196 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Corner (3) 0-0-0 to 3-0-0, Exterior (2) 3-0-0 to 5-0-0, Corner (3) 5-0-0 to 11-0-0, Exterior (2) 11-0-0 to 13-0-0, Corner (3) 13-0-0 to 16-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp D; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for thisdesign. 5)All plates are 2x4 MT20 unless otherwise indicated. 6)Gable studs spaced at 2-0-0 oc.7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members.9)Provide mechanical connection (by others) of truss tobearing plate capable of withstanding 162 lb uplift at joint 14, 283 lb uplift at joint 15, 227 lb uplift at joint 16, 163 lb uplift at joint 12, 279 lb uplift at joint 11 and 221 lb uplift at joint 10. 10)Non Standard bearing condition. Review required. 11)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T05GE Common Supported Gable 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:7KzmvazyXY99FRGzIJFjFbzvmrp-Hlh_3nfaPTU5eXC1AYqc_zhLxjEREBGGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x8 =2x4 =3x4 =4x4 =5x6 =3x4 =4x4 =3x4 =2x4 =4x8 23 24 10 25 9 8 26 27 71 2217 2 6 53 18 21 19 20 4 T2 T1 T2 T1 B1 B2 W2 W1 W2 W1 HW1 HW1 6-08-12 6-08-12 6-08-12 26-10-00 6-08-04 20-01-04 6-08-04 13-05-00 8-11-00 17-10-08 8-11-08 8-11-08 8-11-08 26-10-007-0810-08-04Scale = 1:71.3 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.68 Vert(LL)-0.23 8-10 >999 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.79 Vert(CT)-0.33 8-10 >976 180 TCDL 10.0 Rep Stress Incr YES WB 0.38 Horz(CT)0.05 7 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 108 lb FT = 20% LUMBER TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 Right: 2x4 SPF No.2 BRACINGTOP CHORD Structural wood sheathing directly applied or4-4-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-10-14 oc bracing. WEBS 1 Row at midpt 4-8, 4-10 REACTIONS (size)1= Mechanical, (min. 1-08), 7=3-08, (min. 2-05) Max Horiz 1=-461 (LC 8) Max Uplift 1=-526 (LC 12), 7=-526 (LC 13) Max Grav 1=1476 (LC 1), 7=1476 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-17=-1977/724, 2-17=-1687/746, 2-3=-1804/862, 3-18=-1700/873, 18-19=-1686/880, 4-19=-1686/898, 4-20=-1686/898, 20-21=-1687/880, 5-21=-1700/873, 5-6=-1802/862,6-22=-1685/746, 7-22=-1978/724 BOT CHORD 1-23=-674/1751, 23-24=-674/1751, 10-24=-674/1751, 10-25=-214/1118, 9-25=-214/1118, 8-9=-214/1118, 8-26=-427/1460, 26-27=-427/1460, 7-27=-427/1460 WEBS 4-8=-541/975, 6-8=-645/621, 4-10=-541/980, 2-10=-645/621 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-0 to 3-0-0, Interior (1) 3-0-0 to 10-5-0, Exterior (2) 10-5-0 to 16-5-0, Interior (1) 16-5-0 to 23-10-0, Exterior (2) 23-10-0 to 26-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf.6)Refer to girder(s) for truss to truss connections. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 526 lb uplift at joint 1. 8)Two RT7A MiTek connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 7. This connection is for uplift only and does not consider lateral forces. 9)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Double installations of RT7A require the two hurricane ties to be installed on opposite sides of top plate to avoid nail interference in single ply truss. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T06 Common 6 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:7t1d2CNHW?RLKgtVHSshdmzvmrH-Hlh_3nfaPTU5eXC1AYqc_zhDVj4vE9mGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x6 =3x4 =4x4 =3x4 =3x4 =3x6 31 30 29 28 27 26 25 2423 22 21 20 19 18 171 162 3 15 4 14 5 13126 117 108 9 T2 T1 T2 T1 B1 B2HW1 HW1 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST6 ST5 ST4 ST3 ST2 ST1 13-05-00 13-05-00 13-05-00 26-10-00 26-10-007-0810-08-04Scale = 1:66.5 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.15 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.15 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.38 Horiz(TL)0.02 17 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 149 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 Right: 2x4 SPF No.2 BRACINGTOP CHORD Structural wood sheathing directly applied or6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS T-Brace:2x4 SPF No.2 - 9-25, 8-26, 10-24 Fasten (2X) T and I braces to narrow edge of web with 10d (0.131"x3") nails, 6ino.c.,with 3in minimum end distance. Brace must cover 90% of web length. REACTIONS All bearings 26-10-00. (lb) -Max Horiz 1=-461 (LC 8), 32=-461 (LC 8) Max Uplift All uplift 100 (lb) or less at joint(s) 17, 18, 38 except 1=-356 (LC 10), 19=-310 (LC 13), 20=-152 (LC 13), 21=-189 (LC 13), 22=-197 (LC 13), 24=-158 (LC 13), 25=-146 (LC 11), 26=-172 (LC 12), 27=-193 (LC 12), 28=-181 (LC 12), 29=-188 (LC 12), 30=-171 (LC 12), 31=-279 (LC 12), 32=-356 (LC 10) Max Grav All reactions 250 (lb) or less at joint (s) 17, 20, 21, 28, 29, 30, 38 except 1=392 (LC 9), 18=275 (LC 1), 19=269 (LC 22), 22=266 (LC 19), 24=342 (LC 19), 25=650 (LC 13), 26=342 (LC 18), 27=266 (LC 18), 31=319 (LC 21), 32=392 (LC 9) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-521/516, 2-3=-430/448, 3-4=-386/418,4-5=-347/424, 5-6=-309/488, 6-7=-297/498,7-8=-399/583, 8-9=-493/639, 9-10=-493/615, 10-11=-399/496, 11-12=-266/358, 12-13=-288/348 BOT CHORD 1-31=-252/261 WEBS 9-25=-629/412, 8-26=-301/192, 10-24=-302/177, 15-19=-248/261 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Corner (3) 0-0-0 to 3-0-0, Exterior (2) 3-0-0 to 10-5-0, Corner (3) 10-5-0 to 16-5-0, Exterior (2) 16-5-0 to 23-10-0, Corner (3) 23-10-0 to 26-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 2x4 MT20 unless otherwise indicated. 6)Gable requires continuous bottom chord bearing. 7)Gable studs spaced at 2-0-0 oc. 8)This truss has been designed for a 10.0 psf bottomchord live load nonconcurrent with any other live loads. 9)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection (by others) of truss tobearing plate capable of withstanding 100 lb uplift atjoint(s) 18 except (jt=lb) 1=355, 25=145, 26=172,27=192, 28=181, 29=187, 30=171, 31=278, 24=158, 22=196, 21=188, 20=152, 19=310, 1=355. 11)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12)Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA T06GE Common Supported Gable 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:RUUi4PgKsNTxCMi7hUIJbqzvmqv-Hlh_3nfaPTU5eXC1AYqc_zhLnjEvE9mGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 =4x4 =2x4 =3x4 1 3 4 9 10 2 T1 T1 B1 ST1 4-10 8-00-04 3-07-08 7-07-10 4-00-02 4-00-02 8-00-043-00-060-042-08-10Scale = 1:31.3 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.27 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.25 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.10 Horiz(TL)0.00 3 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MP BCDL 10.0 Weight: 22 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 8-0-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. REACTIONS (size)1=8-00-04, (min. 1-08), 3=8-00-04,(min. 1-08), 4=8-00-04, (min. 1-08) Max Horiz 1=-130 (LC 8) Max Uplift 1=-17 (LC 19), 3=-29 (LC 8),4=-345 (LC 12) Max Grav 1=84 (LC 18), 3=84 (LC 19), 4=796 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-195/287, 2-9=-183/344, 2-10=-183/344,3-10=-195/286 BOT CHORD 1-4=-335/283, 3-4=-335/283 WEBS 2-4=-601/402 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust)Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zoneand C-C Exterior (2) zone; cantilever left and rightexposed ; end vertical left and right exposed;C-C formembers and forces & MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)Gable requires continuous bottom chord bearing. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection (by others) of truss tobearing plate capable of withstanding 17 lb uplift at joint1, 29 lb uplift at joint 3 and 345 lb uplift at joint 4. 8)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA V01 Valley 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:l?dm5JP1BJUesK8ca0Msu_zvmog-Hlh_3nfaPTU5eXC1AYqc_zhJvjDLED7GFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =2x4 =3x4 =2x4 1 3 2 T1 T1 B1 4-10 4-00-04 1-07-08 3-07-10 2-00-02 2-00-02 4-00-041-06-060-041-02-10Scale = 1:29.3 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.13 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.12 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 3 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MP BCDL 10.0 Weight: 9 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-0-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 ocbracing. REACTIONS (size)1=4-00-04, (min. 1-08), 3=4-00-04, (min. 1-08) Max Horiz 1=-62 (LC 8) Max Uplift 1=-81 (LC 12), 3=-81 (LC 13) Max Grav 1=221 (LC 1), 3=221 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-2=-313/159 BOT CHORD 1-3=-110/253 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust)Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zoneand C-C Exterior (2) zone; cantilever left and rightexposed ; end vertical left and right exposed;C-C formembers and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)Gable requires continuous bottom chord bearing. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 81 lb uplift at joint 1 and 81 lb uplift at joint 3. 8)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA V02 Valley 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:dmsGxgSYFY_4LxRNpsQo3qzvmoc-Hlh_3nfaPTU5eXC1AYqc_zhL6jFOEEhGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 =2x4 =2x4 =4x4 =2x4 =2x4 =2x4 =3x4 1 5 8 7 6 42 1613 14 15 3 T1 T1 B1 ST2 ST1 ST1 4-10 13-09-07 6-06-02 13-04-13 6-10-11 6-10-11 13-09-075-02-040-044-10-09Scale = 1:41.5 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.27 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.10 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.13 Horiz(TL)0.00 5 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 43 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. REACTIONS All bearings 13-09-07. (lb) -Max Horiz 1=-229 (LC 8) Max Uplift All uplift 100 (lb) or less at joint(s)1, 5, 7 except 6=-361 (LC 13),8=-366 (LC 12) Max Grav All reactions 250 (lb) or less at joint (s) 1, 5 except 6=496 (LC 22), 7=386 (LC 1), 8=501 (LC 21) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. WEBS 3-7=-308/48, 2-8=-423/396, 4-6=-423/393 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp D; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) 0-0-5 to 2-11-1, Interior (1) 2-11-1 to 3-11-1, Exterior (2) 3-11-1 to 9-11-1, Interior (1) 9-11-1 to 10-9-12, Exterior (2) 10-9-12 to 13-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)Gable requires continuous bottom chord bearing. 5)This truss has been designed for a 10.0 psf bottomchord live load nonconcurrent with any other live loads. 6)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection (by others) of truss tobearing plate capable of withstanding 100 lb uplift atjoint(s) 1, 5, 7 except (jt=lb) 8=365, 6=361. 8)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA V03 Valley 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:w6nwP4Xxbht4g0Tjjq2RrIzvmoV-Hlh_3nfaPTU5eXC1AYqc_zhJvjFhECgGFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =4x4 =4x6 =2x4 =4x4 1 3 4 109 2 T1 T1 B1 ST1 4-10 9-09-07 4-06-02 9-04-13 4-10-11 4-10-11 9-09-073-08-040-043-04-09Scale = 1:34.4 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.36 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.32 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.17 Horiz(TL)0.01 3 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 27 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 9-9-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. REACTIONS (size)1=9-09-07, (min. 1-11), 3=9-09-07,(min. 1-11), 4=9-09-07, (min. 1-11) Max Horiz 1=-161 (LC 8) Max Uplift 1=-34 (LC 19), 3=-37 (LC 10),4=-435 (LC 12) Max Grav 1=91 (LC 18), 3=91 (LC 19), 4=1003 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-236/357, 2-9=-221/457, 2-10=-221/457,3-10=-236/357 BOT CHORD 1-4=-398/322, 3-4=-398/322 WEBS 2-4=-799/530 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust)Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zoneand C-C Exterior (2) zone; cantilever left and rightexposed ; end vertical left and right exposed;C-C formembers and forces & MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)Gable requires continuous bottom chord bearing. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection (by others) of truss tobearing plate capable of withstanding 34 lb uplift at joint1, 37 lb uplift at joint 3 and 435 lb uplift at joint 4. 8)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA V04 Valley 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:ot1RERaRfwNW9enUyg7N?8zvmoR-Hlh_3nfaPTU5eXC1AYqc_zhIVjCGEC1GFUtMjZzlI3b This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 02/14/2022 912 =3x4 =3x4 =3x4 1 3 8 9 2 T1 T1 B1 4-10 5-09-07 2-06-02 5-04-13 2-10-11 2-10-11 5-09-072-02-040-041-10-09Scale = 1:30 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.26 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.23 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.01 3 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MP BCDL 10.0 Weight: 14 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-9-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 ocbracing. REACTIONS (size)1=5-09-07, (min. 1-08), 3=5-09-07, (min. 1-08) Max Horiz 1=-92 (LC 10) Max Uplift 1=-116 (LC 12), 3=-116 (LC 13) Max Grav 1=318 (LC 1), 3=318 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 1-8=-469/235, 3-9=-263/141 BOT CHORD 1-3=-170/383 NOTES 1)Wind: ASCE 7-10; Vult=140mph (3-second gust)Vasd=111mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat.II; Exp D; Enclosed; MWFRS (envelope) exterior zoneand C-C Exterior (2) zone; cantilever left and rightexposed ; end vertical left and right exposed;C-C formembers and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp D; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)Gable requires continuous bottom chord bearing. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 116 lb uplift at joint 1 and 116 lb uplift at joint 3. 8)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply 52 Wilfin Road - S. Yarmouth, MA V05 Valley 1 122010994JR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Oct 22 2021 Print: 8.510 S Oct 22 2021 MiTek Industries, Inc. Mon Feb 14 08:24:40 Page: 1 ID:hfGx4pdyj9tyeF5FBWCJ9_zvmoN-Hlh_3nfaPTU5eXC1AYqc_zhJ4jDfEEhGFUtMjZzlI3b 02/14/2022