Loading...
HomeMy WebLinkAboutEngineer Plan - 2021Permit valid for REPAIR OF SEPTIC SYSTEM LEGEND ONLY, due to State and Local septic variances. Board of Health review and approval is required for — _ 11 _ _ EXISTING CONTOUR s e �- any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. x 100.98 EXISTING SPOT GRADE OVERHEAD WIRES Yarmouth Health Departmeaf— G — EXISTING GAS SERVICE APPRQV 1'D „p —1N— EXISTING WATER SERVICE TEST PIT TU v,< BENCHMARK-2 MAG. NAIL SET ST�9A-ESD {-q�5 3 / p Q BENCHMARK EL.=100.76 Date CRO VE STREET LOCUS MAP 10088 PK SET - NOT TO SCALE 00.76 00,41 GENERAL NOTES: PK SET 00.00 0 9,94 ^. PKSE -� 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL h BOARD OF HEALTH AND THE DESIGN ENGINEER. N, 8-3-57'40" W 101.21 d 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS 0011_ OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE 450 LOCAL RULES AND REGULATIONS 'LOT PARKING Y ��-��b�� 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 4�+S F AREA m TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 10137 FEB ,,. DESIGN ENGINEER. ' 100.79 GDGZ. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 10179 FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN 101-: �\ HEALTH DEPT. ENGINEER BEFORE CONSTRUCTION CONTINUES. =101;85;'..; i 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. a".' r 1 .85 C , 162 i� 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF w x �F THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF f X10 Mgss9 HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. EXISTI 3 T. s 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. p : ` HOUSE(#111) PETER EE � McENT. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 10 61 N � o TO. F.=104.91 -� CIVIL "' 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS zv �'7 " //%/ No. 35109 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE raj rp 0 d MODIFY l/% CI t,F` DIRECTED BY THE APPROVING AUTHORITIES. INTER/OR 0� ^N PROP NEW SEWER x ZN o ,X 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AC INVMe�N 00,4 101. I `E THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING po® ntr x101) q CONSTRUCTION. 0 04 ,Z BENi�IMARK-2 � �� 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 0186 1014 IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND CORNER PATIO REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). EL 01.90N 0 0 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE . P,e PROPOSED SEPTIC TANK kOg INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. �j -7- LQ 714 INFILTRATOR IM1530(OR EQUAL) 13. THIS. PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND -IS INSP. PORT L -i _- 10 29 sprinkler heod(typ.) ^ JOHN m NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC 14' i---1--- LAKN IRRIGATION SYSTEM �"-1 ¢ CHURCy( jR # ' SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. PROPOSED S.A.S. 25'--�I 11 o Ntr, fl6a 4 ROWS OF 4 HI-CAPACITY 102.01 XISTING CESSPOOLS H-20 INFILTRATOR UNITS TO BE PUMPED & REMOVED �F t 101.4 SEE NOTE 11 1 MAP ID: 42-208 VENT S 83.s7=40" E PROPOSED SEPTIC SYSTEM UPGRADE PLAN FLOOD ZONE DESIGNATION 111 GROVE STREET, SOUTH YARMOUTH, MA FIRM NO. 25001CO57J REVISION 2/25 22 Prepared for: Joseph Occhino, 18 Piermont Street, Watertown, MA 02472 .PLAN 1) INCREASE SEPARATION TO GW TO 5' PER BOH REQUEST OWNER OF RECORD Engineers: Surveyors: SCALE DRAWN JOB. N0. FLOOD ZONE DESIGNATION 2) REDUCE S.A.S. SIZE PER BOH REQUEST - TORTOLA, ANGELO TR Eftgln@@flag WOYkf, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 273-21 FIRM NO. 25001CO57J 3) ELIMINATE ALL LUA VARIANCE REQUESTS JOSEPH & LINDA OCCHINO TRUST 12 West Crossfield Rood 2854 Cranberry Hwy. EFFECTIVE DATE: JULY 16, 2014 4) CHANGE D-BOX TO H-10 18 PIERMONT STREET Forestdale, MA 02644 E.Warehom, MA 02538 DATE CHECKED SHEET NO. 0.2% ANNUAL CHANCE FLOOD HAZARD WATERTOWN, MA 02472 (508) 477-5313 (508) 273-0377 11/13/21 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.=99.83 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S.- SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX PROPOSED S.A.S. OUTLET AND SET TO 6' OF FINISH. GRADE INSTALL RISER & WATERTIGHT. INSTALL INSPECTION PORT OVER ONEH ROW(MIN.) T.O.F.=104.9± COVER SET TO 6" OF GRADE F.G. EL.=101.81F.G. EL.=101.6± EXISTING ` F.G. EL.=101.41 F.G. EL 101.9 ,EXISTING HOUSE#111 / MAINTAIN 2% GRADE MIN. OVER S.A.S. T.O.F.= 104.9i' 1x,u ua ar�aoa INSPECTION ® S=1%(MIN.) ®S=1%1(MIN. L - 9 PORT 4"SCH40 PVC TOP OF TANK=100.79 4"SCH40 PVC) 0 S=1% (MIN.) 4"SCH40 PVC a ntr -c t0 44" LIQUID LEVEL 14 a 11 1 11 NVEROT O 2 0 M ADD GAS BAFFLE INV.=99.72 PROPOSED INV.=99.55 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25.0' CA �S. tx Nit BOTT. OF TANK=96.25 INV.=99.95 PROPOSED 1500 GALLON SEPTIC TANK D -BOX INV.=99.44 SOIL ABSORPTION SYSTEM (PROFILE) �- ---- INFILTRATOR IM1530 GALLON PLASTIC TANK INV.=100.20 - ESTABLISH VEGETATIVE COVER CONNECT TO NEW SEWER BACKFILL WITHsaEAN NATIVE OR AT HOUSE, INV.=100.4± PERC SAND TO TOP OF CHAMBERS - �-25~I PROPOSED S.A.S. BREAKOUT -TOP •,' TOP ELEV.= 99.83 �•"'`', F 4 HI-CAPACITY NOTES: INV.= 99.44 .` H 20W INFILTRATOR 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. BOTTOM ELEV.= 98.50 III III�IIIII�II S.A.J. LAYOUT 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND TRUE 5' MIN, SEPARATION 2,83 TO GRADE ON A MECHANICALLY COMPACTED STABLE BASE TO GROUNDWATER OR SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 4' (MIN.) OF NATURALLY EFFECTIVE WIDTH=11.3' 310 CMR 15.221(2). OCCURRING PERVIOUS SOILS SUITABLE SOILS 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.WEDGE HIGH G.W., EL=93.4 - USE 4 ROWS OF 4 -HIGH CAPACITY ADS BIODUFUSER UNITS PLUS 0000 000 0 0 0 0 0 0 0 0 0 0 WITH NO SEPARATION BETWEEN EACH ROW & NO STONE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 SEPTIC SYSTEM PROFILE TYPICAL SECTION- WT,S. Closed End Plate Open End Plate SOIL LOG DESIGN CRITERIA DATE: OCTOBER 28, 2021 NUMBER. OF BEDROOMS: 2 BEDROOMS SOIL EVALUATOR: PETER McENTEE PE, SE -1542--- - WITNESS: PHIL RENAUD. HEALTH AGENT SOIL TEXTURAL CLASS: CLASS ELEV. TP DEPTH �nSLiLIJ� �D DESIGN PERCOLATION RATE: <2 MIN/IN ��� II �{ -I I- 75" -I 34'" DAILY FLOW: 220 GPD 101.9 q LOAMY SAND F�� � i(j 25" .7 Side View End View DESIGN FLOW: 330 GPD 101.1 10YR 4/2 D" GARBAGE GRINDER: NO. - NOT PERMITTED FOR GARBAGE GRINDER BMED. SAND f1T1'i DE 7; HIGH CAPACITY INFILTRATORS, H-20 LOADING PROPOSED SEPTIC TANK: 1500 GALLON. CAPACITY DYR 5/6 PERC 8"/26" INFILTRATOR CHAMBERS LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 99.1 G1 34" .74. GPD/SF N.T.S. DISTRIBUTION BOX: 1 INLET, 4 OUTLETS (H-10) SAND PROPOSED, SEPTIC SYSTEM UPGRADE PLAN USE 4 ROWS OF 4. HIGH CAPACITY INFILTRATOR H-20 UNITS WITH MED. 2.5Y 7/3 NO STONE, WITH NO SPACE BETWEEN ROWS. FOR A 11.3' x 25.0' BED 111 GROVE STREET, SOUTH YARMOUTH, MA Prepared for: Joseph Occhino, 18 Piermont Street, Watertown, MA 02472 SIDEWALL AREA: NOT APPLICABLE 93.4 ADL. G.W. 102" REDOX 7.5YR 5/8 BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF) z (INFILTRATORS) 4 ROWS x 25.0 LF x 4.73 SF/LF = 473.0 SF 92.9 STG. G.W. - tog" Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 273-21 DESIGN. FLOW .PROVIDED: 0.74 GPD/SF(473.0 SF) = 350.0 GPD 91'9 120PERC RATE 2 MIN/IN. ("B"&"C" HORIZONS) 12 West Crossfield Road Forestdale, MA 02644 2854 Cranberry Hwy. DATE E.Warehom, MA 02538 CHECKED SHEET NO. GROUNDWATER ENCOUNTERED AS NOTED (508) 477-5313 (508) 273-0377P.T.M. 11/13/21 2 Of 2