HomeMy WebLinkAboutEngineer Plan - 2019BUILDING 3 V I � N I ° Tf�1 I w ° \ E fat \ 1+ �s 1 \ O \ O 1 \ \ CAUTION: AREA XI ELECTRIC IN AREA OF ROPOSED S TIC \ \ v 40 \ z \ BUILDING 4 s'O a BUILDING 3 VARIANCE REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (lb): TOP OF SAS TO BE GREATER THAN 3' BUT LESS THAN 6' BELOW GRADE (H-20 AND VENT PROVIDED) 15.224: (2): REDUCTION IN MINIMUM HYDRAULIC DETENTION TIME OF 48 HOURS BASED ON THE DESIGN FLOW. 40.9 HOURS OF RETENTION TIME PROVIDED IN FIRST COMPARTMENT. EXTRA CAPACITY PROVIDED IN SECOND COMPARTMENT TO COMPENSATE. EXISTING ' BUILDING #3 TOP OF FNDN EL. 43.6 0 _ 16 bedrooms 1760 GPD O _ 43 1 V O � as cBF,1, PROP. WITH CHARCOAL FILTER F Fy �y AND BU REEN (FINAL PLACEMENT BY CONTRA OR WITH HOMEOWNER x F yf CONSULT TION) 0 QN O v �9 o^tic 1� TEST .HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 10/30/19 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. (Y' 4 41.5' PE 126" 31.0' - NO GROUNDWATER ENCOUNTERED l ` PROP.. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) DCE #>9- BUILDING 5 v � \ LEGEND FILL EXISTING CONTOUR 12" EXISTING SPOT ELEV. -[99]- PROPOSED CONTOUR E PROPOSED SPOT EL. TTH11 MS i.h 16" 1OYR 5/2 40.2' p" B W WATER LINE LS G 22" 1OYR 4/6 39.7' tc C LS MS 42" 1OYR 5/6 10YR 6/6 126" 31.0' - NO GROUNDWATER ENCOUNTERED l ` PROP.. VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR WITH HOMEOWNER CONSULTATION) DCE #>9- BUILDING 5 v � \ LEGEND 99- EXISTING CONTOUR X 99.1 EXISTING SPOT ELEV. -[99]- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TTH11 SOILS i.h TEST HOLE 2� SLOPE OF GROUND p" UTILITY POLE W WATER LINE G GAS LINE - - E ELECTRIC LINE NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING BUILDING 4 VARIANCE REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (lb): TOP OF SAS TO BE GREATER THAN 3' BUT LESS THAN 6' BELOW GRADE (H-20 AND VENT PROVIDED) 15.224: (2): REDUCTION IN MINIMUM HYDRAULIC DETENTION TIME OF 48 HOURS BASED ON THE DESIGN FLOW. 40.9 HOURS OF RETENTION TIME PROVIDED IN FIRST COMPARTMENT. EXTRA CAPACITY PROVIDED IN SECOND COMPARTMENT TO COMPENSATE. C TEST HOLE LOGS VITH CHARCOAL FILTER ENGINEER: DANIEL E. GONSALVES, SE #13587 :EN (FINAL PLACEMENT BY WITNESS: PHIL RENAUD - WITH HOMEOWNER �) DATE: 10/30/19 - PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 4-1 :HMARK - 0" 42.2' E SET - A - = 43.5' LS 3„ 1OYR 3/3 E MS 9„ 1OYR 5/2 41.5' B LS 1OYR 4/6 20 40.5' PERC FV C k� MS 1OYR 6/8 132" 31.2' NO GROUNDWATER ENCOUNTERED TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 10/30/19 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. lu p" 40.4.' FILL 26" B LS 42" 1OYR 5/6 36.9' PERC C MS 2.5Y 7/4 LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 56 PARCEL 11C LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AND ZONE X (0.2 PCT ANNUAL CHANCE FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO586J DATED 7/16/2014 SITE IS WITHIN A ZONE II NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -Q (H-20 LEACHING CHAMBERS) 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. EXISTING WALKWAYS TO BE REMOVED AND REPLACED AS REQUIRED. Permit valid for REPAIR OF SEPTIC SVSfENI ONLY, due to State and Local septic varlJoles. Board of Health review and approval is required tar auY future a(It it ionslrenovations/alterations to sewage facilities and/or structures/dwelling. Vannuoth Health Department APPROVED 1-113lul Nam Date BUILDING 5 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (lb): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 16.2') & SLAB (10' TO 5'), TOP OF SAS TO BE GREATER THAN 3' BUT LESS THAN 6' BELOW GRADE (H-20 AND VENT PROVIDED) 15.224: (2): REDUCTION IN MINIMUM HYDRAULIC DETENTION TIME OF 48 HOURS BASED ON THE DESIGN FLOW. 40.9 HOURS OF RETENTION TIME PROVIDED IN FIRST COMPARTMENT. EXTRA CAPACITY PROVIDED IN SECOND COMPARTMENT TO COMPENSATE. E OF 222 BUCK ISLAND ROAD WEST YARMOUTH, MA PREPARED FOR 126" I�J 29_9' BASSETT POND CONDOS NO GROUNDWATER ENCOUNTERED .�� DATE: NOVEMBER 25, 2019 REV: JANUARY 10, 2020 (SAS SIZE, VARIANCE NOTE) OF hiAt, Scale: 1 = 20' DANIEL �m 8 OJALA 0 10 20 30 40 50 FEET 0JPLA 1"� A No 40980 off 508-362-4541 3g ti DAN ; fax 508-362-9880 �L rt ' downca pe.com y Noa6�G`o�Na .9 9 ng �e down code eineering, mc. civil engineers land surveyors ` 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 I DATE DANIEL A. OJALA, P.E., P.L.S. SHEET 1 OF 2 19-374 BASSETT POND CONDO.DWG TOP FOUND. EL. 43.6' PRECAST H-10 RISERS (TYP.) 2'0 PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 10^ EXISTING 14^ TEE SEPTIC TANK** TEE GAS BAF *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM FOUNDATION- EXIST. - SEPTIC TANK #1 **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 3000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 3500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE D. EL. 42.5' PRECAST H-10 RISERS (TYP.) 2'0 BUILDING 3 SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE I ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. VENT W/ CHARCOAL FILTER H-20 CAST IRON COVI-'RS TO GRADE 2% SLOPE REQUIRED OVER SYSTEM 41.5'-43.0' J J J MIN. 2" WALL THICKNESS PRECAST H-10 BLOCKS OR S. n RISERS (TYP.) PRECAST RISERS j!j4"0SCH40 PVC ..: ,., .. PIPES LEVEL 1ST 2' 4 COMPONENTS o MORTAR ALLH 20 ENDS (TYP.) 6 SIDES39.06 $ 0 15I0pd 10• 2500 GAL H-10 14^ 39.16' TEE SEPTIC TANK TEE E1 8'91 0000000 - ° oo�000®ooao 000®0000®oo °000° ondy P nd GAS BAFFLE.. °o°o 0°0°0. N 0 ° o ���0®®®�®®® ®®®®®®®®®[]o� 00 0°0 1: 4' LIQ. LEVEL (ACME OR EQUAL) •7: 38.78' 38.61' ,00g°0000 M®LLDE2®®Of]00® °°000aoo 36.06' y 0 3 0000nov0000000°00000000000ve°o°00000a 6" MIN. SUMP `. 0 „0000000°000°°„°"o"o,°,0�000°0. 12" MIN. INT. DIM. LH -20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. - 3/4"-1-1/2" DOUBLE WASHED STONE (16) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 144.0' X 12.83' COMPACTION. (15.221 [21) (2 SLOPE) (-!--% SLOPE) (-1-7 SLOPE) N LOCUS MAP - 2' SEPTIC TANK #2 13' D' BOX 57' LEACHING SCALE 1"=2000'± PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 10" EXISTING 14" TEE SEPTIC TANK** TEE GAS BAF *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM FOUNDATION- EXIST. - SEPTIC TANK #1 **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 3000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 3500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE TOP FOUND. EL. 43.1' PRECAST H-10 RISERS (TYP.) 2'0 FACILITY BUILDING 4 SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE I 13.3'± POND ELEVATION ASSESSORS MAP 56 PARCEL 11C LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AND ZONE X (0.2 PCT ANNUAL CHANCE FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO586J DATED 7/16/2014 SITE IS WITHIN A ZONE II ALL SYSTEM COMPONENTS SHALL BE NOTES MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. VENT W/ CHARCOAL FILTERI. DATUM IS NAVD 88 H-20 CAST IRON COVERS TO GRADE 2. MUNICIPAL WATER ISXE ISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. -- - 2% SLOPE REQUIRED OVER SYSTEM 42.0'-43.0' j j ------ MIN. 2" WALL THICKNESS 4. DESIGN LOADING --FOR- ALL _PROPOSED PRECAST UNITS PRECAST H-10 BLOCKS OR _ _-------TO"BE AASHO H -].Q (H-20 LEACHING CHAMBERS) _ _..- RISERS (TTP.) 4"OSCH40 PVC PRECAST RISERS --- - _" PIPES LEVEL 1sT -2' 4 TORTAR s H-20 - - 5. PIPE JOINTS TO BE MADE WATERTIGHT. •, _._ - - COM_PONEN _ _ ENDS (TYP.) __ 4 - - --_ 10" 2500 GAL H-10 14- ' ., D 0 BE IN ACCORDANCE WITH 51 ES 6 CONSTRUCTION DETAILS T 38.28 38.63' TEE SEPTIC TANK TEE ..: a ®�®® ®®®® F-53 _®®®� �`'o 310 CMR 15.000 (TITLE 5.) 8.38' oo° o°°°° o° m�®®®®®®®�® ®® ° ° GAS BAFFLE.. "0000000°000 o 0000gog o®�®®®®®® °°°° 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO ®®®�®®o®®®® ®®®®®®A®®® " BE USED FOR LOT LINE STAKING OR ANY OTHER 4' LIQ. LEVEL (ACME OR EQUAL) .' 38.0' 37.83' °o°o `�' 'oog °°°° PURPOSE. ° 35.28 o°o°o°o o..o�oe000.p,o. u000uao°.000°000 oeV; 6" MIN. SUMP 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40-4" PVC. °O0000°aP 12" MIN. INT. DIM LH -20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2'• DOUBLE WASHED STONE (16) UNITS REQUIRED 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED 6" CRUSHED STONE OR MECHANICALWITHOUT INSPECTION BY BOARD OF HEALTH AND OVERALL DIMENSIONS TO OUTSIDE OF STONE: 144.0' X 12.83' COMPACTION. (15.221 [23) PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING (-1-7 SLOPE) (-L-7 SLOPE) (-L-7 SLOPE) N DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES - 7' SEPTIC TANK #2 38' D' BOX 57' LEACHING PRIOR TO COMMENCEMENT OF WORK. FACILITY 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE 13.3'± POND ELEVATION REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. EXISTING WALKWAYS TO BE REMOVED AND REPLACED AS REQUIRED. PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 10" EXISTING 14" TEE SEPTIC TANK** TEE GAS BAF PRECAST H-10 RISERS (TYP.) BUILDING 5 SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE I ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. VENT W/ CHARr'O&L FILTER H-20 CAST IRON COVERS TO GRADE 2% SLOP�RE6 OVER SYSTEM 41.0'-42.0' d, MIN. 2" WALL THICKNESS BLOCKS OR 4'0SCH40 PVC AR ALL PRECAST RISERS PIPES LEVEL 1ST 2' OMPONENTS H-- 4 (TYLE) NV' 6.4 4'--. ENDS _ SIDES ° 2500 GAL H 10 _ 38.64' . UTIEE E SEPTIC TANK TEE 8.39' ®O� ®® ° 0°0 °o°°0000 °° ° ° o®®o®®®®o MM MMDO®®®® ' GAS BAFFLE ,_ocono„o0o, N ° o o ®9®®0®®M®® MM MMM® '14' LIQ. LEVEL (ACME OR EQUAL) f 37.62' 37.45' ogo/ '°'000go°o° 34.9' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM (� 7 SLOPE) FOUNDATION- EXIST. - SEPTIC TANK #1-4' **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 3000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 3500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE DCE #19-374 ,00soQ0000000soeoc000000� 6" MIN. SUMP ' } 12" MIN. INT. 11M. `H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE (16) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 144.0' X 12.83' COMPACTION. (15.221 [2]) (3_7 y° SLOPE) SLOPE) c SEPTIC TANK #2 21' D' BOX 57' LEACHING FACILITY ._IL_ SITE OVERVIEW Scale:1 "= 70' 0 35 70 105 140 175 FEET 13.3'± POND ELEVATION SYSTEM DESIGN: �- SYSTEM DESIGNS FOR BUILDINGS 3, 4, & 5. 3 SYSTEMS PROPOSED. 1 FOR EACH BUILDING. GARBAGE DISPOSER IS NOT ALLOWED EXISTING 16 BEDROOM CONDO BUILDING DESIGN FLOW: 16 BEDROOMS @ 110 GPD = 1760 GPD USE A 1760 GPD DESIGN FLOW SEPTIC TANK: 1760 GPD (2) = 3520 (1ST COMPARTMENT) 1760 GPD (1) = 1760 (2ND COMPARTMENT) 3520 + 1760 = 5280 GAL. REQUIRED USE EXISTING 3000 GAL. SEPTIC TANK & ADD A 2500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (144.0 + 12.83) 2 (.74) = 464 GPD J \ 1 BOTTOM 144.0 x 12.83 (.74) = 1367 GPD I TOTAL: 2475 S.F. 1831 GPD �I USE (16) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND LEGEN D 99 -- EXISTING CONTOUR X 991 EXISTING SPOT ELEV. -[99]- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 TEST HOLE 27' SLOPE OF GROUND Cob UTILITY POLE WATER LINE -W- GAS LINE -G- ELECTRIC LINE - E NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING APPROVED DATE , MA BOARD OF HEALTH TO ACCOMPANY TITLE%e."1'J'V'ITEPLAN OF 222 BUCK ISLAND ROAD WEST YARMOUTH, MA PREPARED FOR BASSETT POND CONDOS T'=- DATE DANIEL A. OJALA, P.E., P.L.S. DATE: NOVEMBER 25, 2019 REV: JANUARY 10, 2020 (SAS SIZE, VARIANCE NOTE) off 508-362-4541 fax 508-362-9880 downcope.com down cope engineering, Inc. civil engineers land surveyors 939 Mcin Street ( Rte 6A) YARMOUTHPORT MA 02675 SHEET 2 OF 2 19-374 BASSETT POND CONDO.DWG