HomeMy WebLinkAboutReview Checklist D ,B °X .S.-=,-.. Gl('�- o . I- ' TOWN OF YARMOUTH -t-3+ ( -- - SEWAGE PLAN REVIEW CHECKLIST Location: A.M. `./.5" Lot 'Y 7 Zone of Contribution: In /Out_ Acreage Commercial: Residential: V Street: . /q f34fri -4- .. Village: IS f t/��,,, Floor Plan: #Bedrooms: 3 Owner Z.o# p, t'7, /QInstaller: 0 Address: /' Phone: Phone: Builder: Engineer: iDq/7 Si2t4r/4'-r,i/O 24s '- Address: /� Phone: Phone: / N/A YES NO 1.Required#of copies received l� 2.Date of soils exam and percolation test not older than 2 years ✓ 3.4-5 ft of naturally occurring pervious material,above water table ✓ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: V 6.Benchmark indicated and shown=NGVD if near wetlands V 7.Septic tank minimum 10 ft from foundation, deck Var.: ` 17 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: g / (") 9.Leaching minimum 100 ft from wetlands Var.: V. 10.Leaching minimum 150 ft from drinking well/25 ft irrigatioll Var.: L/ 11.T cll. minimum 10 ft from property line Var.: ir s7- c,-,5#•)-)6. C . 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: N✓` 15. System not in top or subsoil(A,B horizons)or 5'removal ✓ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"pref / 18. System meets breakout requirements OVC liner. <`Wall: C) ru 19. Specified tee sizes are proper, gas baffle on outlet tee V, 20. Sewage is under 10,000 gpd for parcel V 21.No garbage disposal 22. System adequately sized for its intended use ✓ 23.Minimum 6"stone or compacted below tank and dbox 16 24.Manhole covers within 6"of grade,pump chamber cover to grade V 25.Inspection port on plastic chambers/leach field / V 26.Electrical permit for pump chamber/Separate meter for duplexes ./ 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size / 28. Septic tank/pump chamber to be factory waterproofed / 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber / 31.Engineer to inspect and certify soils: wall: commercial: ✓ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature V. 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature n 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map f Plan reviewed by: r/- I°/3(i?" 6/03/03