HomeMy WebLinkAboutEngineer PlanKEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR •--•••••••••- EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 5.5 TEST HOLE: * UTILITY POLE: -0- FENCE LINE: HYDRANT: -6- RETAINING WALL: ASSESSORS MAP: 47 PARCEL: 112 LAND COURT CASE 33985 25.0' LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: --?- BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY SEPTIC TANK: 220 GAL / DAY x 2 DAYS = 440 GAL USE J -M 1-MGALLON SEPTIC TANK (EXISTING) LEACHING AREA: (3 BEDROOM MINIMUM DESIGN) USE 2.500 GALLON CHAMBERS (8.5' x 4.8' x Z EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25' x 12.8' x 2' EFF. DEPTH) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) = 112 GALIDAY. BOTTOM AREA: 25' x 12.8'= 320 SF (0.74)=.3U,GAVDAY SEPTIC SYSTEM SECTION (EXISTING) 1MV GAL SEPTIC TANK TEE SIZES; (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET; 6" UP, 14" DOWN TEE A INLET -GAS BAFFLE AT OUTLET TEE 2" PEASTONE OR FILTER FABRIC 3/4"-1 1YP DOUBLE WASHED STONE FINISHED GRADE INSPECTION PORT// , -� i--ELEV.=102.33 1/4" per It _ J$M14 • • 111w 99.5 K � ELEV. e 25'x 12.8'--� 2.500 GALLON CHAMBERS WITH 5.6' 4' OF STONE ALL AROUND (25'x 12.8'x 2' EFF, DEPTH) ADJUSTED GROUND WATER ELEVATION - 93.9 .E N104.0 GARAGE TEST HOLE LOGS O/AHORIZON €Lwv. FLUME COURT Permit valid for REPAIR OF Steil( SN I vrW ENGINEER: THOMAS MeLELLAN,P.E. LOAMYSAND WITNESS: MALLORY LANGLER, R.S• 10' 8 HR IZ 10 .2 ONLY, due to State and Lural + r"' ""•""'es• - BHORIZON \ / Board of Ilealth review end :µa r„� '• "' t"' eil for PD ATH PORCH LND DATE: 521-20 LOAMY SAND any future additionshe"," dt„ao u, to BED PERCOLATION RATE: <2MIN/IN 24" t0YR6/8 ,p 106 sewage fardities and/Or'truet" 11ma ROOM SH130.00' BTH C HORIZON Yarmouth Ilealtb n „„�rnt pT• 2N7/4 SANDPERCAT4K LIVING USGS GROUND WATER ADJUSTMENT: 1106 A P PRO \ 1 • i) ROOM DECK WELL: MIW-29, ZONE: 8, ADJ: 0.9' / 132" OBSERVED 93.0 DINING ADJUSTED GROUND WATER ELEV.- 93,9 ,t/ 144" GROUND WATER 92.0 I m o I N l,0 30 b EXISTING FLOOR PLAN Nn -Name NOTES: M I r�: 1. VERTICAL DATUM: ASSUMED m \` 2. MUNICAPAL WATER IS AVAILABLE. I I 105 3. SCHEDULE 40 --4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 104 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORMy01TH AASHTO H-20 SPECIFICATIONS. Lu I 877 °8'01"B 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHER BE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL, V/ � Stone okatla F� 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 2 fOy� � ce ` �Parking 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL z . `+ 1?," oak \ 102 100 CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 03 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. a\` �3(`� ;: • • J 101' 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED ' WITHOUT VARIANCE. 106' '''SSSS ; J t 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. QPG' the Q 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND 12" oak ' IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY P'A dA dF ka REPRESENT A FULL DETAILED PROPERTY SURVEY. X00 OoS = 13. EXISTING FLOWDIFFUSORS TO BE ABANDONED IN PLACE. JC LG s 1 QP`t O,t, \ca• G� 105 ¢ I Q j 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW, 00 ° O JUN 1 1 2020 1 t 0ryp `. Q' HEALTH DEPT. �ypQ ,d,` `♦�� / 104 l �� 7,0 / I SITE PLAN j co w� �%�' n`. 103` ' LOCATION: 'o•� og. �♦ toy 10f ASH OF Mq 16 FLUME COURT, W. YARMOUTH" MA ! 1 ofss9� � `�`♦ / THOMA8 J. PREPARED FOR: 110.00' • ) °45'38" W io��, TERRY N` McLELLAN JOHN NUTCHELL N 84 ♦ � 6 ANN`,,n'� c CIVIL rn WARNER y N0.38471 i I No. 38721 DATE: 5-22-20 SCALE: F'= 30' BENCHMARKAT I B �p RIGHT CORNER .ss� 51EP °' SfONAL�O EG ELEVATION L .f/ BASS RIVER ENGINEERING ELEVATIONATION== 106.91 G }r 0 7'l THOMAS J. McLEL AN, P.E. P.O. BOX 1163, AST DENNIS, MA 02641 M20-29 508-364-9048