Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out!\ Acreage 1 1 '�� q Commercial: Residential: Street: U Village: Floor Plan: y,/ #Bedrooms: Z. Owner: Installer: Address: Phone: Phone: Builder'. Engineer: TOM lilt& it&et Address: Phone: Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring_pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: i/ 6.Benchmark indicated and shown-=NGVD if near wetlands i/ _ 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ✓ 9.Leaching minimum 100 ft from wetlands Var.: V 10.Leaching minimum 150 ft from drinking wei_1/25 ft irrigation well Var.: t/ 11.Tank/leaching minimum 10 ft from property line Var.: t - 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: ,� 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable t� 17. System meets slope requirements-min. 1/8", '/<"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal V 22. System adequately sized for its intended use v/ 23.Minimum 6"stone or compacted below tank and dbox t/" 24.Manhole covers within 6"of grade,pump chamber cover to grade V. 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size / 28.Septic tank/pump chamber to be factory waterproofed ,/ 29.Vent provided if leaching below 3 feet,under driveway/parking . :uoyancy calculations for tank/ g chamf�er 4r. V 31. ngineer to inspect and certifyV0,11612 61 soils: all: .''commercial: 17---; Engineer/Registered Sanitarian and Land Surveyor stamps/signature t.,-' 33.H-20 loading is subject to vehicular traffic, groundwater t/ 34.Title V Application and permit fee,installer signature 1/Z a ' 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots for groundwater/Label lioundwater in Assessor's Map I Plan reviewed by: &'o