HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out!\ Acreage
1 1 '�� q Commercial: Residential:
Street: U
Village: Floor Plan: y,/ #Bedrooms: Z.
Owner: Installer:
Address: Phone:
Phone:
Builder'. Engineer: TOM lilt& it&et
Address: Phone:
Phone:
N/A YES NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring_pervious material, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: i/
6.Benchmark indicated and shown-=NGVD if near wetlands i/ _
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ✓
9.Leaching minimum 100 ft from wetlands Var.: V
10.Leaching minimum 150 ft from drinking wei_1/25 ft irrigation well Var.: t/
11.Tank/leaching minimum 10 ft from property line Var.: t -
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: ,�
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5'removal
16.Proposed contours are suitable t�
17. System meets slope requirements-min. 1/8", '/<"preferred
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal V
22. System adequately sized for its intended use v/
23.Minimum 6"stone or compacted below tank and dbox t/"
24.Manhole covers within 6"of grade,pump chamber cover to grade V.
25.Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size /
28.Septic tank/pump chamber to be factory waterproofed ,/
29.Vent provided if leaching below 3 feet,under driveway/parking
. :uoyancy calculations for tank/ g chamf�er 4r. V
31. ngineer to inspect and certifyV0,11612 61 soils: all: .''commercial: 17---;
Engineer/Registered Sanitarian and Land Surveyor stamps/signature t.,-'
33.H-20 loading is subject to vehicular traffic, groundwater t/
34.Title V Application and permit fee,installer signature 1/Z
a '
35.Foundation footing min.2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37.Check area lots for groundwater/Label lioundwater in Assessor's Map I
Plan reviewed by: &'o