Loading...
HomeMy WebLinkAboutEngineer Plan - 2022Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED wF # svea"A ) 444 311 VaMte Date / / V Wf Z#2 If #I ' _n v i 102 / LEGEND WF #5-� PROPOSED CONTOUR / ® PROPOSED SPOT GRADE / --gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE -W- EXISTING WATER SERVICE TEST PIT Too SCALE 1"=20' LOT 20 I 1081 .,4 SL0 20 1 1,061.4 5. F. 104.4`\ d�G� aQ' 104. \. �O.(O 105.1 105.5 s APPROXIMATE LOCATION OF EXISTING SEPTIC SYSTEM IOG.O (PER TOWN A5-13UILT) 0�8 104 o �, PROP. I ,500E � --lob, SEPTIC TANK` WETLAND FLAGGING BY: IOGZ `? ' 5 FT 501L BRAD HALL 00' 1 , REMOVAL SETBACK , SURVEY BY: 108 TEM = EL 108.6 WELLER AND ASSOC. TOP OFCONC.BND. VARIANCE REQUESTS - MAXIMUM FEASIBLE COMPLIANCE 1) A 10 Fr. VARIANCE FROM 310 CMR 15.211/YARMOUTH REDS TO ALLOW PROP. LEACHING TO BE A MIN. OF 10 Fr. FROM DWELLING VS. REQUIRED 20 Fr. II i 105.7 0 106.0 \ 104 LSOd�DD DDMAR , 3 2022 HEALTH DEPT. GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS NOTED. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING TANK/LEACHING PIT TO BE PUMPED, CRUSHED AND FILLED PER TITLE 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. ALL PIPING TO BE 4" SCH 40 0 1/8 -/FT (UNLESS SPECIFIED) 15. REMOVE UNSUITABLE SOILS SFT. AROUND LEACHING AS SHOWN TO EL103.3 OR TOP OF "C° LAYER AND REPLACE W/CLEAN MED. SAND PER TITLE 5. 16. PLACE 40 ml POLY LINER AS SHOWN AT EDGE OF SOIL REMOVAL FROM EL 104.30 TO 100.30 TO PREVENT INFILTRATION TO BASEMENT. 17. REFER TO YARMOUTH CONSERVATION'S STANDARD CONDITIONS FOR CONSTRUCTION REQUIREMENTS. WEST YARMOUTH RO�TF %\ ?8 Q= S/mss 2 CRUISER LN. Q� �R �<v Able. LEWIS BAY BLVD LOCUS MAP LOCUS INFORMATION PLAN REF: 173/003 TITLE REF: 33289/120 PARCEL ID: MAP 023 PAR. 088 FLOOD ZONE: NOT IN FLOOD ZONE PROPERTY NOT IN ZONE II SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 2 CRUISER LANE WEST YARMOUTH, MA PREPARED FOR PAUL HARROP/ READY ROOTER EXC. JANUARY 31,,2022 REV: FEBRUARY 25, 2022 H OF OF STEVEN W. RUMBA No. 3§'B/91 4-.'i I -2z.' MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:104.28 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. T.O.F. EL.=107.50 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. F.G. EL.= 106.0 F.G. EL.=106.55f F.G. EL: 106.00f F.G. EL: 107.20(MAX.) . N.�JN.f.IiJ • yA:V .,.. 9" MIN COVER/ �. L = 12'1 36" MAX COVER L = 30' L = 15'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) S=1% (MIN.) EL = 105.80 0 S=1% (MIN.) 4"SCH40 PVC 0 S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 10• •" u" 8• 11" TO 48" LIQUID LEVEL INV.=104.76 'EIEC INV. =104.51 GAS BAFFLE PROPOSED INV.=104.04 4 ROWS OF 4 UNITS AT 6.25'/UNIT WEDGE = 25.0'/ROW D -BOX INV.=104.21 I1 03.89 PROPOSED 1.500 GALLON SEPTIC TANK - SOIL ABSORPTION SYSTEM (PROFILE) RESTORE VEGETATIVE COVER OF SAS EXISTINGINVENER 105.0 OUTLETS BACKFILL WITH CLEAN PERC SAND s�Cy TO TOP OF CHAMBERS �Q� o DA EN M. wwY BREAKOUT=TOP ELEV.=104.28 0. -1 INV. ELEV.= 103.89 / G�SfEQ NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING BOTTOM ELEV.= 102.95 EXISTING SANITAR�a PIPE INVERTS PRIOR TO CONSTRUCTION. 2.83' MATERIAL 5' MIN. ABOVE BOTTOM OF }2 2) TANK/D-BOX SHALL BE SET LEVEL AND TRUE TO EFFECTIVE WIDTH = 4 x GRADE MECHANICALLY COMPACTED SIX T.P. EXCAVATION OR G.W. (5.05' PROVIDED) USE 4 ROWS OF 4 -HIGH CAPACITY INCH CRUSHED STONE BASE, AS SPECIFIED IN ADJ. GROUNDWATER EL.=97.90 - INFILTRATOR (H20) UNITS 310 CMR (2) _ 75" 3) INSTALL INLET & OUTLET TEES W/ LET & GAS BAFFLE AS REQUIRED SEPTIC SYSTEM PROFILE TYPICAL SECTION N.T.S. s.ns DESIGN CRITERIA **PROP IS NOT IN ZONE OF CONTRIBUTION** SOIL LOG NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DATE: JANUARY 5, 2022 SOIL TEXTURAL CLASS: CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: PHIL RENAUD, HEALTH YARM. DAILY FLOW: 330 G.P.D. Elev. TP -1 Depth 16" SO DESIGN FLOW: 330 G.P.D. 105.70 A 0" GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) LOAMY OOYR 4/, PROPOSED SEPTIC TANK: 330gpd x 200% = 660 gpd (USE PROP. 1,50OG CAPACITY) 104.95 B 9" LEACHING AREA REQUIRED: (330) = 445.95 S.F. LOAMY SAND SECTION INVERT 10YR 5/6 HEIGHT END CAP .74 DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) 103.03 C 32" INFILTRATOR - HI CAPACITY (H20) CHAMBER PRIMARY S.A.S. MEDIUM USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE SAND 2.5Y 7/3 BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) PROPOSED SEPTIC SYSTEM SITE PLAN (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473 SF 96.62 109" 2 CRUISER LANE, W. YARMOUTH, MA TOTAL AREA = 473 SF PERC RATE <2 MIN/IN. (-Cl- HORIZON) GROUNDWATER OBSERVED AT 108" EL. 96.70 Prepared for: Harrop/Ready Rooter EXC. WELL• MIW-89, ZONE B. LEVEL 7.9, ADJ: 2.2' USE HEALTH DEP". ALLOWED ADJ. OF 1.2' Engineering by: MEYER & SONS, INC Surveying by: Meller to Associates SCALE NTS DRAWN D.M.M. DATE: 01/31/22 DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd ADJUSTED GROUNDWATER EL- 97.90 * I, Darton M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 POBOX981 (508) 328-4692 to conduct sail evaluations and that the above analysis has been Performed by me consistent with the EAST SANDWICH, MA 02537 REV DATE: CHECKED SHEET NO. requirements of 310 CMR 15.017. l further certify that I have passed the Soil Eval. Exam in October, 1999. 508-362-2922 02/25/22 D.M.M. 2 Of 2