Loading...
HomeMy WebLinkAboutEngineer PlanLOCUS DATA OF EDWARD 4 A CURRENT OWNER LEWIS BAY STONE REALTY TRUST No.28980 PLAN REFERENCE 332-91 L DEED REFERENCE 8985-324 ZONING DISTRICT R-25 FLOOD ZONE AE, ELEV 11 ASSESSORS MAP 16 PARCEL 47 OVERLAY DISTRICT NONE LOT AREA 28,464± S.F. SITE & SEWAGE REPAIR PLAN ,753 LEWIS BA Y BOULEVARD IN YARMOUTH, MASS DATE: FEBRUARY 2, 2022 REV: FEBRUARY 22, 2022 OWNER/APPLICANT: JOSEPH A. D'AMICO ZABELLE D'AMICO 53 LEWIS BAY BLVD. WEST YARMOUTH SHEET 1 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM NX01 CAV, CONTRACTOR TO COORDINATE THE RELOCATION OF THE ELECTRIC SERVICE AS REQUIRED,,, 71 U' PROPOSED0LEACHING 2 EXISTING CESSPOOL TO BE PUMPED & REMOVED PROPOSED "D` BOX (6) OUTLET PROPOSED 1,000 GALLON PUMP CHAMBER PROPOSED 1,500 GALLON SEPTIC TANK / OQ� 06 �� p0 5 9- 187.7 \ r e' PORT 10.0' 110.1' BENCHMARK: MAG NAIL SET IN BIT. PAVEMENT ELEVATION = 10.75 #53 \\ EXISTING \/ 6 BEDROOM �T 3A\ S4t S.F. 1 GAR. 28 N ¢ SILVER w � m LEWIS BAY BLVD. \ Th LOCUS LEWIS BAY \ LOCUS MAP i 1\ dj NOT TO SCALE: U1�ss � Q� D.T.H. 1 84.0' / 7Q� ' q \ �8 SEE FLOOR PLANS ATTACHED. o,0o, '9STOG,� ,9` O tiF,TO 22-0104 Yarmouth Health Department Name a w N 00 N 0 30 45 60 O GRAPHIC SCALE: 1 INCH = 30 FEET 18 0 S=0.02 c 4" PVC CH 40 INV.= 'a INV.= 8.36 7.00 t 4 BAND STAINLESS 5' -7 - = 7.54 STEEL CONNECTOR 4'-61/2 = COVER 22-0104 FINISH GRADE ELEV. 9.0 10"TEE 14"TEE ZABEL FILTER 4'-1" LIQUID, LEVEL RAISE (3) COVERS TO 6" OF FINISH GRADE 4" PVC SCH 40 V^ INV.= 6.72 G.WATER 2.5 )M 2.46 PROPOSED 1,500 GALLON SEPTIC TANK SET ON 6" STONE OR LEVEL STABLE BASE WATERPROOF AT FACTORY SITE & SEWAGE REPAIR PLAN /753 LEWIS SA Y BOULEVARD IN YARMOUTH, MASS DATE: FEBRUARY 2, 2022 REV: FEBRUARY 22, 2022 OWNER/APPLICANT: JOSEPH A. D'AMICO ZABELLE D'AMICO 53 LEWIS BAY BLVD. WEST YARMOUTH SHEET 2 OF 3 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS.SURVEYQYAHOO.COM DOSING CALCULATIONS: DESIGN FLOW TO CHAMBER REQ'D EMERGENCY STORAGE EMERGENCY STORAGE PROV'D NUMBER OF DOSING CYCLES DEPTH PER CYCLE GALLONS PER DOSE DESIGN TDH (5.37'+2.30') DESIGN GPM RUNNING TIME RAISE (1) 24" COVERS TO FINISH GRADE SH GRADE V.V. 9.0 TOP =h /O PUMP CONTROLS RAISE COVER TO WITHIN 6" OF FINISH GRADE FINISH GRADE ELEV. 10.5 ELEV. 10.4 2" TO 4" 6' ®S= 0.01 TOP I EXPANDER n F 8' 0 6_.. , vl 2 PVC SCH 40 6 OUTLET H-20 DB6 r---iELDEV. 2.5 TER a-°- BOTTOM 2.28 PROPOSED 1,000 GALLON PUMP CHAMBER SET ON 6" STONE OR LEVEL STABLE BASE WATERPROOF AT FACTORY = 660 GPD = 660 GAL = 672 GPD (2.69' x 250G/FT) = 4 PER DAY / TITLE V = 8" INCHES = 165 GAL/DOSE (0.67'x250 G/F = 7.37 FEET = 40 GPM = 165 GAL - 40 GPM = 4.125 m +/or 4 MIN 7 SEC. HORIZONTAL "T" MAN HEALTH DEPT OBSERVATION PORT(S) TO GRADE / SCREW ON CAP OF COVER MAX 25'x36' LEACHING FIELD =8.18 INV.= 6 LINES -4" PIPES 4' ON CENTER cc OBSERVATION PORT TO GRADE / SCREW ON CAP 6 LINES 4' ON CENTER 25' END VIEW 0" 20" DIA MIN. MANHOLE COVER 24" DIA MIN. MANHOLE COVER BROUGHT TO WITHIN 6" 1BROUGHT TO FINISH GRADE OF FINISH GRADE TIE ENDS & VENT IF REQUIRED STRIPOUT TO "C" HORIZON PER 310 CMR 15.255 (C) \ ELEV. 7.5 0 0 N N LEV. 2.5 G.WATER TH#1 APPROX. 12" TOP ELEV. = 7.54 = COVER - QUICK DISCONNECT 1 4" PVC 2" PVC DISCHARGE SEPTIC TANK BUOYANCY CALCULATIONS 1 INV.= 6.72 ER. ao 6.52 PIPE INV 6.52 1500 GALLON H-10 ALARM ELEV.= 4.03 32 STOR�= 1/4" WEEP HOLE BOTTOM OF TANK AT ADJUSTED GROUNDWATER g — o CHECK VALVE PUMP ON EL. = 3.70 _ w 4 °� CC 2" SCH 40 w 1 --:PVC THREADED 3° 8' w n O PIPE PUMP CHAMBER BUOYANCY CALCULATIONS PUMP OFF EL. = 3.03 a w m 2 MERCURY FLOAT 1000 GALLON H-10 (MINIMAL) BOT. INS. = 2.61 = 5" a W .'°J ADJ. G.WATER LEVEL CONTROLS BOT. EL = 2.28 dneaR°� 'Of %-% �c.q n�1Gi� r_Qj�i: r_�. �'QD,_9,%-% �i qt e°'a A,_ ta; MYERS 0.4 HP SEWAGE PUMP (MODEL SMR) 6" MIN. 3/4" TO 1 1/2" STONE OR EQUIVALENT 1,000 GALLON LOCATE UNDER MH PRECAST CONCRETE PUMP TO HANDLE PUMP CHAMBER MIN. 2" SOLIDS CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2, NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S.AREA IS PROHIBITED PUMP NOTES 1. POWER CABLES TO BE PLACED IN CONDUIT IN ACCORDANCE WITH LOCAL BUILDING AND WIRE CODES. 2. PUMP AND ALARM TO BE ON SEPERATE ELECTRICAL CIRCUITS. 3. PUMP ALARM TO BE SET AT A CONVENIENT LOCATION ADJACENT TO THE BUILDING AND TO BE BOTH AUDIO AND VISUAL. 22-0104 SITE & SEWAGE REPAIR PLAN #53 LEWIS BA Y BOULEVARD IN YARMOUTH, MASS DATE: FEBRUARY 2, 2022 REV: FEBRUARY 22, 2022 OWNER/APPLICANT: JOSEPH A. D'AMICO ZABELLE D'AMICO 53 LEWIS BAY BLVD. WEST YARMOUTH SHEET 3 OF 3 EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. B. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4.INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. DATUM: VERTICAL DATUM: NAVD-1968 BENCH MARK USED: MAG NAIL SET IN PAVEMENT ELEVATION 10.50 NONE HEALTH DEPT. DTH #1 10 P-1 U45„ SYSTEM DESIGN EXISTING DESIGN FLOW 6 BEDROOMS AT 110 GPB/D 66ZQ GPD REQUIRED SEPTIC TANK 660 x 2-_ = _I320 _ GAL. SEPTIC TANK PROVIDED = -1.50Q-GAL. GAL PUMP CHAMBER PROVIDED = -AQ-0--GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE --: 2 __MIN./INCH LONG TERM APPL. RATE0.74 GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 660 _ 0.74 SF/GPD = -M-S.F. MIN. REQ, USING A 25' x 36' LEACHING FIELD WITH A MINIMUM OF 6" STONE UNDERNEATH 25' x 36' = 900 S.F. 900 x 0.74 G/SF = 666 GPD 666 GPD PROV > 660 GPD REQ.= 6 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) D.T.H. #1 ib DATE: JAN. 19, 2022 GROUND ELEV. 11.2 NO GROUNDWATER A 10YR 4/3 LOAMY SAND 4" B 7.5YR 6/6 LOAMY SAND 30" INDICATES DEEP TEST HOLE INDICATES PERC TEST C NO MOTTLING 2.5Y 7/4 MED. SAND NO WEEPING _ .10. 105' INDICATES ADJ. GROUNDWATER EL. = 2.5 = 1-? "120" B.O.H. PHIL RENAUD / BRUCE MURPHY SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. ELLIS BROTHERS SOIL TYPE: 1_ PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN