HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 35 Lot C, Zone of Contribution: In Out_✓Acreage�14� i- Commercial: Residential: Street: t-i5 Hecc{,t,uct� 5 Pc,u-e Village: Floor Plan: ✓ #Bedrooms: 3 Owner: Lem 4--Vt c_t t.r,c.,. , F-,,;. S ---f" Installer: '10 0 e.r -t- ! ) 00✓ ( Address:t S- l'.va.,,,,.o of I2cI, i-t-a.,ti.; ci.,.. Phone: (Spcs) `-l'l 1 - Sb-7'7 Phone: Builder: Engineer: a---c,„Ev vvQAt-vt v Address: Phone: (Sa S) 3 -0 3-1-)--) Phone: N/A YES NO 1.Required#of copies received V 2.Date of soils exam and percolation test not older than 2 years V 3.4-5 ft of naturally occurring pervious material,above water table V. 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: V 6. Benchmark indicated and shown-NGVD if near wetlands f 7. Septic tank minimum 10 ft from foundation, deck Var.: ✓ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: / f 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: -✓ 11.Tank/leaching minimum 10 ft from property line Var.: / 12. System meets all other setback requirements Var.: 3),1 /13.Uses adjustment for maximum high groundwater Var.: I �/ 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: V 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable / 17. System meets slope requirements-min. 1/8", %"preferred Ni 18. System meets breakout requirements PVC liner: Wall: -17 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 7 21.No garbage disposal ‘.7,- 22. f 22. System adequately sized for its intended use �/ 23.Minimum 6"stone or compacted below tank and dbox 7 24.Manhole covers within 6"of grade,pump chamber cover to grade V 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes i 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 7 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 1 30.Buoyancy calculations for tank/pump chamber .7 31.Engineer to inspect and certify soils: wall: commercial: 7 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature / 7 33.H-20 loading is subject to vehicular traffic,groundwater ✓ 34.Title V Application and permit fee,installer signature 1- 35. 35.Foundation footing min. 2 feet above adjusted ground water for new house .„...;-> 36.Deed Restriction required max. #bedrooms: max.flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: !'nr-zi. in)!41Yhkr 2/lJ/ dL 6o;oa