HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out creage r I �� Commercial: Residential: x " ► t Street: J Village: Floor Plan: 4€' # Bedrooms: Owner: Installer: cat t Address: Phone: Phone: ��n.(!N /L,,e I`/ Builder' Engineer: 17044 Mt a-frk- Address: Phone: Phone: N/A YES/ NO 1.Required#of copies received ✓ 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table vV 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: v' 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: i . 9.Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11. Tank/leaching minimum 10 ft from property line Var.: 1/ 12. System meets all other setback requirements Var.: - 13. Uses adjustment for maximum high groundwater Var.: - V 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons) or 5' removal t...107Ll 1yi `/f 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", ''A"preferred v 18. System meets breakout requirements eyfrmW jar PVC liner: V Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel t - 21.No garbage disposal ✓ 22. System adequately sized for its intended use 23. Minimum 6" stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade • ✓� 25. Inspection port on plastic chambers/leach field / 26. Electrical permit for pump chamber/Separate meter for duplexes v�/ 27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size _ 28. Septic tank/pump chamber to be factory waterproofed �' 29. Vent provided if leaching below 3 feet, under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify 1>'t 1- f 1 soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓ _ 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd / 37. Check area lots for groundwater/Label groundwater in Assessor's Map / Plan reviewed by: 6/03/03 ✓