HomeMy WebLinkAboutEngineer PlanKEY: EXISTING CONTOUR: - - - - PROPOSEDCONTOUR: EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: -* UTILITY POLE: -O- FENCE LINE: - HYDRANT: --6- RETAINING WALL: 4 LOCATION MAP LOT 132 (12, 100 SF) ASSESSORS MAP: 125. PARCEL: 107 PLAN BOOK: 204, PAGE: 57 LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL I DAY LC TANK: GAL / DAY x 2 DAYS= 660 GAL 1000 GALLON SEPTIC TANK (EXISTING) ELEACHINGAREA:LON CHAMBERS (8.5'x 4.6'x ZEFF.DEPTH) WITH AROUND SIDES AND ZAT ENDS (29 5'x9.8'x2'DEEP) 29.5'+9,8')x2x2=157SF (0.74)=116 GAIJDAY : 29S' x 9.8' = 289 SF (0.74) = 2 4 GAL/DAY CAPACIT =_330 L/DAY SEPTIC SYSTEM SECTION :`ti .'.INC) 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN 1/4" per ft _ E E D -BOX EL (8" OF STONE UNDER OR v MECH/AN_ ICALLY COMPACTED) / 102.17 +/ ELEV. -GAS BAFFLE AT OUTLET TEE DECK bh TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. / KITCHEN BATH BED WITNESS: MALLORY LANGLER, R.S, �J .LINER DINING BATH ROOM DATE: 5-28-20 !R= 103. / AREA PERCOLATION RATE: <2 MIN/IN :NATIO =101.0 1`i, „gyp 1i�(J D LIVING BED ROOM GARAGE ROOM ROOM BED 104 .'',`'- 12" pine 1 103 102 / 24' oak 12' oqk.:. NT4�BQ5"SOt44�4�. 12 pini th1 100exssiVc� e / l l t � • i tanK ! d 7 ct \ ,I All \SvAG 00 pWELa1N10138 top 1n JI EXISTING FLOOR PLAN bh 100 (dE. \ C�PaP W . \ s G 1 0A5"`N- 101 1 y6 S1a /�Ed9avement 100 „✓ ' � � , � SEN S�RE�T I • 106.76 Permit , d ,r REPAIR OF SEPTIC SYSTEM. ON1.1, t q ne and Local sepfie variances. Board,d ew and approval is required for any fw a,I,t,wrns/renrtvations/alterations to sewage I r. ,mvor structyxey/dwelling. I •-011 11ealtfi 0erpartment ROVED I Name Date rNo3 SANN � /I q) /00 2" PEASTONE OR FILTER FABRIC DOUBLE S INSPECTION PORT �- ELEV.= 103.0 . 1' 1 ,10_0 .7 . o . . H ELEV. S T-2.5' 32.500 OF STONE CHAMBERS ROUND SIDESH AND 2' AT ENDS (29.5'x 9.8' x Z EFF. DEPTH) TH-1 105.5 --j ELEV. B HORIZON PERC AT 36" LOAMYSAND 10YR 5/8 110,.5 C HORIZON MEDIUM SAND 12612.5Y 7/4 126" 95.0 /// NO GROUNDWATER ENCOUNTERED N NOTES: 1. VERTICAL DATUM: ASSUMED 2, MUNICAPAL WATER IS AVAILABLE, 3. SCHEDULE 40.4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM, 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE), 8. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8 ALL TLCONSTRUCTION DETAILS OCL RE TOO E IN CONFORMANCE O O FR ANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TIE 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12, THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH PIT IS TO BE PUMPED AND REMOVED. ✓/ 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. JUN 2 4 ZO2O HEALTH DEPT SITE PLAN LOCATION: { of mss$ 139 EILEEN ST YARMOUTHPORT MA DMAS J. cy4 PREPARED FOR: ,LE IJ AN GLEN RAYMOND CIVIL y DATE: 5-28-20 SCALE: 1" = 20' `SS/O- 01� BASS RIVER ENGINEERING_ THOTvtAS J. McLEL N, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048