Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /Z-4 Lot Zv Zone of Contribution: In Out )( Acreage 39, 24.415 F Commercial: Residential: I/- Street: Street: V S S ,ems Co A Village: Floor Plan: #Bedrooms: -5-- Owner: /-f-U 4 f+E-5 Installer: /Z.c-,41-3 c( Address: Phone: Phone: Builder: Engineer: vC&-'`/'&.4--_ Address: Phone: Phone: N/A YES NO 1.Required#of copies received I/ 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table ,/ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: V 5.Water line 10 ft from septic components Var.: ,V 6.Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation,deck Var.: V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ,/ 9.Leaching minimum 100 ft from wetlands Var.: I 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓ 11.Tank/leaching minimum 10 ft from property line Var.: ,/ 12. System meets all other setback requirements Var.: ,/ 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ,/ 15. System not in top or subsoil(A,B horizons)or 5' removal ,/ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred V 18. System meets breakout requirements PVC liner: Wall: / 19. Specified tee sizes are proper, gas baffle on outlet tee / 20. Sewage is under 10,000 gpd for parcel / 21.No garbage disposal ✓ 22. System adequately sized for its intended use / _ 23.Minimum 6"stone or compacted below tank and dbox V 24. Manhole covers within 6"of grade,pump chamber cover to grade V 25. Inspection port on plastic chambers/leach field / 26. Electrical permit for pump chamber/Separate meter for duplexes ,/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ,/ 28. Septic tank/pump chamber to be factory waterproofed V 29.Vent provided if leaching below 3 feet,under driveway/parking / 30.Buoyancy calculations for tank/pump chamber / 31. Engineer to inspect and certify soils: wall: commercial: / 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature / 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee,installer signature / 35. Foundation footing min. 2 feet above adjusted ground water for new house ,/ 36.Deed Restriction required max. #bedrooms: max.flow: gpd / 37. Check area lots for groundwater/Label groundwater in Assessor's Map PIan reviewed by: S i 4 (70Z1-- _ 6ozos