Loading...
HomeMy WebLinkAboutEngineer PlanQ O 49.3 LL-1� TOP OF PIPE @ EL. 48.4± 5O L O N c °� \tel T, p F 4 FC. S0.O EL. 48. 1 /ROLJTE 03'_ GIA LOT A&B 39,204± S.F. (0.90± AC.) 0 TOP Of PIPE [) 46Bi ------------------------ 48 I- I 47.5 / W / reM: �47. / TOP CENTER OF RAMP / @ EL. 48.7 / TOP OF PIPE 49.1 @ EL. as.3 GA 47.8 GE g,/46.8 �NKryp0s GREEN ryousi � \ F a Yarmouth Health Department APPROVE r�'.4fcD H,AA'S � a,zS� name Date LEGEND -� PROPOSED CONTOUR 9® PROPOSED SPOT GRADE --gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE -------- ---- 47 47' 9' 0 46.5 $ O Y I I / o / 45.2 1 -1 130°' \ �t \ `9 06 —W— PROPOSED WATER SERVICE 0 TEST PIT Scale: 1"=30' -FEB 'i d 2422 rWEL VEY CONDUCTED BY:LER AND ASSOC. YARMOUTH ROUTE 6A LOCUS 455 ROUTE 6A m A LOCUS MAP LOCUS INFORMATION Z N� PLAN REF: LCP 11785-B TITLE REF: D273552 PARCEL ID: MAP 124 PAR. 020 PROP. NOT IN ZONE II FLOOD ZONE: "X" COMMUNITY PANEL: 25001-CO578-J DATED:07/1 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 455 ROUTE 6A YARMOUTH, MA PREPARED FOR DIANE HUGHES/ READY ROOTER EXC. FEBRUARY 18, 2022 STEVEN W RUMBA No. 35799 9L i5J@Ct OF 1140 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 376 TOP OF PROPOSED TAHK NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FOUNDATION INSTALL RISERS W/IN 6" OF FINISH GRADE EL. =50.0 FINISHED GRADE46.0 � EL.47.50t F.G. EL: 46.50 � (46.0) J L MAINTAIN 2% MIN SLOPE OVER LEACHING AREA EL.44.83 .q . ..� . PIPESTW FL 2 ' IN/WT D -B01( ; 2" OF 3/8" DOUBLE WASHED _ _ 6,M 1/2 STONE OR FILTER FABRWIC OUBLE WASHED' STONE (� D 10"I14 14" 14" 4" SCH 40 PVC TEE'S ARE TO BE 6" @ S= 1% (MIN.) ®®®®'®®®®®®® Exist. Inverts 4" SCH 40 PVC INV: 42.75 ® INV.= 48.10 INV:43.50 10006 > 1053535353535353535353 ®INV= 48.17 1,5000 COMP.J INV: 43.25 2 EFF. DEPTH ®53®®®0100000 ®INV.= 46.22 COMP. GAS GAS INV: 42.55 BAFFLE 4' 4 X 8.5' 4' ®INV.= 46.05 BAFFLE PROPOSED DB -5 H-20 DISTRIBUTION BOX EFFECTIVE LENGTH = 42' PROPOSED 1,500/1000 GALLON INV. ELEV.= 42.30 2 -COMPARTMENT SEPTIC TANK BREAKOUT NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING ELEV.= 43.30 PIPE INVERTS PRIOR TO CONSTRUCTION TOP CONC. ELEV.= 43.30 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE INV. ELEV.= 42.30 5353®®®®® TO GRADE ON A MECHANICALL COMPACTED SIX 53535353535353 INCH CRUSHED STONE BASE, AS SPECIFIED IN 53®535353®® 5353®®®®® 310 CMR 15.221(2) BOTTOM EL.= 40.30 4' 5 FT. 4' 3) INSTALL INLET & OUTLET TEES AS REQUIRED SEPARATION 5.05 FT. EFFECTIVE WIDTH = 13' SEPTIC SYSTEM PROFILE HIGH GROUNDWATER EL: 35.25 r SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON LEACH CHAMBER) GENERAL NOTES: SOIL LOGS DESIGN CRITERIA NUMBER OF BEDROOMS: 5 BEDROOM DESIGN I. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL DATE: DECEMBER 8, 2021 SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) BOARD OF HEALTH AND THE DESIGN ENGINEER. SOIL EVALUATOR: DARREN MEYER, RS, CSE 1614 DESIGN PERCOLATION RATE: MIN IN 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS : <MIN/ IN THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE WITNESS: PHIL RENAUD, YARMOUTH HEALTH DAILY FLOW: 110 G.P.D. X 5 BR = DESIGN FLOW: 550 G.P.D. LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR GARBAGE GRINDER: NO (not designed for garbage grinder) TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE Elev. TP -1 ps SEPTIC TANK: 550 d x 200% = 1,100 d DESIGN ENGINEER. Depth gP gP 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 46.50 0" USE PROP. 2,500 GAL 2 -COMPARTMENT (1,500/1,000) SEPTIC TANK FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN A LOAMY SAND ENGINEER BEFORE CONSTRUCTION CONTINUES. 45.50 10YR 3/2 12" LEACHING AREA REQUIRED: (550)/0.74 = 743.24 S.F. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. B LOAMY SAND USE FOUR (4) 500 GALLON PRECAST LEACH CHAMBERS W/4' 6 THE THE CONIGN TRACTORNORRIS OWNERTTO�NOTIFY THE LOCAL BOARD OF PONSIBLE FOR THE FAILURE OF 42.83 10YR 5/6 44" �� OF Mqs STONE ON ENDS & 4' STONE ON SIDES: 42' L x 13' W x 2'D 7. WAFTER SUPPLYTH FOR ROPER P PROVIDED PBYTTOWN WATER SERVIONS DURING CONSTRUCTION. PERK o C1 FISgNDED. ��P�' 'r9�y 41.17 2 G f; BOTTOM AREA: 42 x 13 = 546 SF 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED 2.5Y 7/4 DARREN M. TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 39.50C2 84" o Y R �'-i SIDE AREA: (42 + 13) X 2 X 2 = 220 SF 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE `'-NO. 11 0 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING MEDIUM SAND TOTAL SQUARE FEET PROVIDED = 766 vs. 743.24 REQ'D CONSTRUCTION. 2.5Y 6/4 DESIGN FLOW PROVIDED: 0.74(766 S.F.) = 566.8 G.P.D. vs. 550 G.P.D. req'd 10. EXISTING LEACHING (LOCATIONS UNKNOWN) TO BE PUMPED, CRUSHEDS1r."" /� AND FILLED PER TIRE 5. REPLACE W/ CLEAN MEDIUM SAND AS NEEDED. 3525 135• S4 ITAR�P� iCI`r�17./ PROP. SITE AND SEWAGE PLAN . 11. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPECIFIED) Ib 12. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION PERC RATE <2 MIN/IN. (-Cl- HORIZON) 455 MAIN STREET, YARMOUTH, MA 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. NO GROUNDWATER OBSERVED 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. Prepared for: Hughes/Ready Rooter Exc. 15. SLEEVE SEWER LINE, WITHIN 10 FT. OF MAIN WATER SERVICE. Site Plan Design and Surveying by: SCALE DRAWN DATE MEYERAND SONS INC N.T.S. DMM 02/18/22 PO BOX 981 SANDWICH, MA 02537 REV DATE CHECKED SHEET NO. 508-3603311 DMM 2 of 2