Blde-22-002961
or ttu Commonwealth of Official Use Only '4 Massachusetts Permit No. BLDE-22-002961 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:11/21/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 11 JUPITER LN Owner or Tenant MAKREDES JOANA AGUERA Telephone No. Owner's Address AGUERA JOSE&MAKREDES NICHOLAS H, 11 JUPITER LN, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(22 Panels 7.81 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiation_Devices No.of Ranges No.of Air Cond. TTotal No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.,of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Eauivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) ❑ owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 tN.K4. ! Commonwealth o/Ma.43acleu.4elh Official Use Only t` 't Permit No. eV.- ly Cok.I 0I_a 2eparlmnl o` ire Serviced t j 51 Occupancy and Fee Checked ,,,-- _1 BOARD OF FIRE PREVENTION REGULATIONS [Rev. (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(ME ), 27 CMR 1 00 (PLEASE PRINT IN INK OR ALL INFO ATION) Date: I i (4, 2J1 • TYP City or Town of: 4400 To the Inspector of Wires:JJJ is application the undersigned i es notice of his or her intention to perform the electrical work described below. ! i Loc tion(Street&Number) , c r Ow er or Tenant -10 r Telephone Ne-05 216- 1-QWe,O N tow er's Address same as above k oo n I ,___, As t is permit in conjunction with a building permit? Yes 2 No ❑ (Check Appropriate Box) 0 � Tu ose of Building dwelling Utility Authorization No. 6V LL I --- 1*-- xi tin W�g Service Amps ��)'olts Overhea ._ Undgrd❑ No.of Meters l M i �T Service Amps / Volts Overhead❑ Undgrd 0 No.of Meters "` umber of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of roof mounted photovoltaic solar systems, - panels "ter .?1 kW Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires SwimmingPool Above ❑ In- ❑ No.of Emergencyy Lighting grnd. grad. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones of No.of Switches No.of Gas Burners No. Initiatinnggon Dete and In Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices g Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices Municipal No.of Dishwashers Space/Area Heating KW Local❑ Connection ❑ Other No.of Dryers Heating Appliances KW Securi No o Systems:* Devi es or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring: Y g No.of Devices or Equivalent OTHER: j C Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of lectri al Work: 13 9 C 1 • (When required by municipal policy.) Work to Start:r2 Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE CO ERA E: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE Et BOND 0 OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services LIC.NO.: Licensee: Nathan Ashe Signa a jL.L .. _. LIC.NO.:21136A (Ifapplicable,enter"exempt"in the license number line.) �'°''^ • "' No.:9785943519 PP P ..�. .: ' gti.... Tel. Address: 695 Myles Standish Blvd Taunton MA 02780 - ,• . �':; :,•'', ::_= = �¢=;Alt.Tel.No.:8573343116 *Per M.G.L.c. 147,s.57-61,security work requires Depaitineritof' afi icalety ' is Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:7810W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), r t SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(22)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE LTD:LR4-60HPB-355M INSTRUCTIONS. " PV-2.0 SITE PLAN •INVERTERS: (1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. LM J MAIN PANEL •I • 1 PV-3.0 LAYOUT •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. „I xl PV-4.0 ELECTRICAL TRACK ON COMP,SEE DETAIL SNR-DC-00436 -SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER ? CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER ATTIC VENT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. o PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INN/ INVERTER(S) ,3 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 71 T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC DISCONNECT(S) FIRE SETBACKS •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)). CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(8)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE I— INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION SHOWN AS DASHED L 1 SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER VICINITY MAP C C #180120 COMP COMPOSITION y DC DIRECT CURRENT a�" (E) EXISTING 695MYLESSTANDISHBLVD,TAUNTON,MABFiBB-T331 PH e+"� "' « ESS ENERGY STORAGE SYSTEM vFAAXX0 ° EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC JOANA MAKREDES MSP MAIN SERVICE PANEL 11 JUPITER LN,YARMOUTH,MA, r� .,Q (N) NEW 02664 's Q 9 .<G NTS NOT TO SCALE '^' OC ON CENTER TEL.(508)398-0840 ! PRE-FAB PRE-FABRICATED APNITMK#:YARM-000050-000084 PSF POUNDS PER SQUARE FOOT _.. PV PHOTOVOLTAIC• PROJECT NUMBER: RSD RAPID SHUTDOWN DEVICE 223R-011MAKR ::0 TL TRANSFORMERLESS DESIGNER (415)415 580-6920 ex3 TYP TYPICAL " V VOLTS JOHN ESTANISLAO ©' W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET 9 0 REV:A 11/12/2021 Q PAGE PV-1.0 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE■1/16"■V-0" PITCH AZIM AZIM (SQFT) AR-01 23° 352° 366° 176.5 AR-02 23° 171° 185° 254.9 JUPITER LN PL PL PL g O (N)ARRAY AR-01 PMAEI INV 0 (N)ARRAY AR-02 FAc SE -- ❑ - (E)RESIDENCE- sunrun #180120 OW MYLES o STANDISH BLw,TAUNTON,MA,OIIBP]331 PHONE FAX 0 CUSTOMER RESIDENCE: JOANA MAKREDES 11 JUPITER LN,YARMOUTH,MA, 02664 TEL.(508)398-0840 APN/TMK#:YARM-000050-000084 PL �--- PROJECT NUMBER: PL 223R-011MAKR DESIGNER: (415)580-6920 ex3 JOHN ESTANISLAO SHEET SITE PLAN REV:A 11/12/2021 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD;3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 12'-7" 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'-0" 1'-10" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'_ 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" 4'-0" 1'-10" STAGGERED STRUCTU 2.5L MIN EMBEDMENT STRUCTURAL NOTES: 12" COMP,SEE DETAIL SNR-DC-00436 • INSTALLERS SHALL NOTIFY P - -SCALE:3/16"■ ENGINEER OF ANY PITCH:23° 1'-0" POTENTIAL STRUCTURAL AZIM:352° 1 -7"— 1T-5" 20' { ISSUES OBSERVED PRIOR TO PROCEEDING W/ 11" o �i INSTALLATION. • IF ARRAY(EXCLUDING IRT)fS �� ROOF PLANEWITHIN 2" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS),THEN 10'4" ATTACHMENTS NEED TO mom � ADDED OVERHANG BE REDUCED WITHIN THE 12" El BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT pm MIO SPACING INDICATED ON PLANS TO BE REDUCED BY 50% 3'-3" ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS P • •SCALE:114"■1'XREF s u n ru n PITCH:H:23 23° }2'_1"t--- 46 6" -- 2'-1'} AZIM:171° 2'-1" 1 0 8— _ 0 E3 #180120 ONMYLES STAMM/1 BLVD.TAUNTON,MA.027.1331 i ___� PHONED 7--ll FAX 0 L_J CUSTOMER RESIDENCE: 0 9 0 0— ❑ 0 JOANA MAKREDES 11 JUPITER LN,YARMOUTH,MA, 8'TYPEij 02664 13'-9" TEL.(508)398-0840 0 0 0 o--. O Q Q n 0 0 ❑ ❑ APNRMK#:YARM-000050-000084 I STRUCT PROJECT NUMBER: 223R-011MAKR ONL 41N OF iVgS°_ "- Aot cyb DESIGNER: (415)580 6920 ex3 C) 0 C) �-i 0 C O a VINCENT w� JOHN ESTANISLAO c4 MWUMVANFZA H CIVIL SHEET • 2'T_ ___ ^ av ��Q LAYOUT -` _ •-- ONAIE10- REV:A 11/12/2021 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE < OMETER#: EVERSOURCE 2308571 UTILITY GRID I 1. SUPPLY SIDE TAP rc ,0 SOLAREDGE TECHNOLOGIES: SE6000H-US WITH REVENUE C 1 EXISTING 100A (N)LOCKABLE (N)MA SMART GRADE METERING(PN MAIN BREAKER BLADE TYPE UTILITY (N)LOCKABLE SE8000H-USS3),6000 WATT t FUSED AC REVENUE BLADE TYPE INVERTER I DISCONNECT METER AC DISCONNECT 6000 WATT INVERTER JUNCTION BOX PV MODULES /� \3 ` OR EQUIVALENT LONGI GREEN ENERGY TECHNOLOGY _ EXISTING RAJ AAAJ X / CO LTD:LR4-60HPB-355M 100A < MAIN off.®. ® off---o I i `^ +(�j�/ (22)MODULES FACILITY PANEL i OPTIMIZERS WIRED IN: 35A FUSES I I (1)SERIES OF(9)OPTIMIZERS LOADS-1FACAJTVSQUARED 240V METER SOCKET SQUARED LOAD RATED DC DISCONNECT (1)SERIES OF(13)OPTIMIZERS D222NRB 100A CONTINUOUS DU222RB WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT 3R,60A,2P COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- 120/24OVAC (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHNTTHWN-2 NONE (1)10 AWG THHNITHWN-2 $u n ru n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHNTTHWN-2 (1)8 AWG THHWTHWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 Mro/SAES STANDISH BLVD,TAUNTON,MP Imorni PHONE 0 FAX O CUSTOMER RESIDENCE: JOANA MAKREDES 11 JUPITER LN,YARMOUTH,MA, 02664 MODULE CHARACTERISTICS TEL.(508)398-0840 P401 OPTIMIZER CHARACTERISTICS: LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN/TMK#:YARM-000050-000084 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-011 MAKR OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.25 A SYSTEM CHARACTERISTICS-INVERTER 1 JOHN ESTANISLAO SYSTEM SIZE: 7810 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 13 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 11/12/2021 SYSTEM OPERATING CURRENT: 20.55 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 INVERTER 1 NOTES AND SPECIFICATIONS: Ai •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC DISCONNECT(S),AC SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC POWER SOURCE AIL LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(DX2),IFC 2012: SYSTEM 605.11.1.4 CAUTION . LABEL LOCATION: UTILITY SERVICE METER AND MAIN ■ SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) MULTIPLE SOURCES OF POWER C I Er L 1,.., , ..I-..I .,I:.x.111.1j`";; 11 SOLAR PANELS ON ROOF 1111 111 `,Z DO NOT RELOCATE THIS lihuhl OVERCURRENT DEVICE LABEL LOCATION: 11 11INSTALLED WITHIN 3.ONEA202SHUT DOWN MAIN PANEL(TNT) 1 s u n run LABEL LOCATION; SWITCH PER C HIN 3'FRAPID S 6UT.D WN),IFC ADJACENT TO PV BREAKER AND ESS 2012:805.11.1,IFC 2018:1204.53 AC DISCONNECT(INT) 11OCPD(IF APPLICABLE). 111 PER CODE(S):NEC 2020: —4• up 705.12(B)(3)(2) INVERTER(EXT) #160120 SOLAR PV SYSTEM EQUIPPED 695 MULES STANDISH BLVD,TAUNTON,MA 00804331 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN PV METER(EXT) F°HONE ° COMBINER PANEL DO NOT ADD LOADS CUSTOMER RESIDENCE: JOANA MAKREDES LABEL LOCATION: 11 JUPITER LN,YARMOUTH,MA, PHOTOVOLTAIC AC COMBINER(IF 02664 APPLICABLE). 3" TURN RAPID SHUTDOWN PER CODE(S):NEC 2020:705.12(D)(2x3xc) SWITCH TO THE"OFF" geta AC DISCONNECT(EXT) TEL(508)398-0840 POSITION TO SHUT DOWN APN/TMK#:YARM-000050-000084 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT 25.00 AMPS SHOCK HAZARD IN THE 223R-011 MAKR NOMINAL OPERA?ING AC VOLTAGE 240 VAG ARRAY. SE SERVICE ENTRANCE DESIGNER: (415)580-6920 Mx3 LABEL LOCATION: 11 JUPITER LN, YARMOUTH, MA, 02664 JOHN ESTANISLAO AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. • `LABEL LOCATION: — --- - SHEET SIGNAGE PER CODE(S):NEC 2020:690.54 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 11/12/2021 PER CODE(S):NEC 2020:690.56(C)• PAGE PV-5.0