HomeMy WebLinkAboutBLDE-22-004442 Commonwealth of Official Use Only 1�` i Massachusetts Pennit No. BLDE-22-004442 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/9/2022 Ns City or Town of: YARMOUTH To the Inspector of Wires: Q By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 36 MAINE AVE , �^. Owner or Tenant TEDESCO ROBERT J TRS Telephone No. Owner's Address TEDESCO NANCY A TRS, 32 WINFIELD ST, DEDHAM, MA 02026 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. , Existing Service Amps Volts Overhead 0 Undgrd 0 No of Meters New Service Amps Volts Overhead 0 Undgrd 0 N eters Number of Feeders and Ampacity a (r7-' Location and Nature of Proposed Electrical Work: Installation of solar PV system(10 Panels 3.25 KW) Completion of the following table may be waiv y the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law. But my signature below,I hereby waive this requirement. I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 (PLA6g rig- ) Coaunonaroa/h o/1//a0eae/Waal Official Use/Ontl'y•. ir. Et c7 Permit No. 22 '1"T 1 W�id� a Aparimanf el3ra&micas 11 i ; Occupancy and Fee Checked e' BOARD OF FIRE PREVENTION REGULATIONS [Rev.I/071 (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC).527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/4/2022 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)36 Maine Ave.02673 Owner or Tenant Robert Tedesco Telephone No. 178I1 707-81 l 3 Owner's Address same as above Is this permit in conjunction with a building permit? Yes No❑ (Check Appropriate Box) Purpose of Building,,ddrw\e\lline Utility Authorization No. Existing Service Lk—) Amps 120 / 240 Volts Overhead Undgrd No.of Meters 1 New Service Amps / Volts OverheadC Undgrd_ No.of Meters 1 Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of roof mounted solar panels.10 panels 3.25kVf NO BATTERY STORAGE Completion of the following table may be waived by the Inspector of Wires. al No.of Recessed Luminaires No.of Ceil:Sus (Paddle)Fans No.of totA P• Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires SwimmingPool Above In- No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No. n Deten and I nitiatinggon Devices No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained P Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Loci (Municipal I I�er l Connection u No.of Dryers Heating Appliances KW SecN of Devices or Equivalent 1 No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent 1 No.Hydromassage Bathtubs No.of Motors Total HP TelecommunicationsN ceor Wiring:qui 1 No.of Devices Equivaent OTHER: Attach additional detail if desired.or as required by the Inspector of Wires. Estimated Value of Electrical Work: 5632.00 (When required by municipal policy.) Work to Start:3/4/2022 Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has IIIeexxhiibited proof of same to the permit issuing office. CHECK ONE: INSURANCE I/ BOND OTHER ElSpecify:) - •• I cerli ,under thepains and of t Iy I'FiIDlties a �,tlmt.NtC motion on this applicalrnd fi3 :e and complete. FIRM NAME:Sunrun Installation Services LIC.NO.: Licensee: Nathan Asilp S ture j -fle LIC.NO.:21136A II/applicable enter"exempt''in the license number line) 4s.Tel.No.:9785943519 Address' 695 Myles Stondi3h Blyd Toun A t.Tel.No.: Per M.G.L.c.I s. - I,security work requires uepa ent of Public Safety•'S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liabilitM.i as rance cprorage normally required by law. By my signature below,I hereby waive this requirement. I am the(check on owner owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE:$ SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:3250W DC,3840W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), MI SOLAR MODULES •MODULES:(10)JA SOLAR:JAM60S17-325/MR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET •INVERTERS:(1)DELTA ELECTRONICS:M4-TL-US INSTRUCTIONS. Nig —� PV-2.0 SITE PLAN •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. TRACK ON COMP,SEE DETAIL SNR-DC-00436 MP MAIN PANEL PV-3.0 LAYOUT •RAPID SHUTDOWN:(10)APSMART RSD-S-PLC ROOFTOP •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. IPV-4.0 ELECTRICAL MODULE LEVEL RAPID SHUTDOWN DEVICE SNR MOUNT •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. 125 AMP MAIN PANEL WITH AMP MAIN BREAKER. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER •SERVICE ENTRANCE CONDUCTORS RS TOOBE REPLACED. CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 0 SUNRUN METER ATTIC VENT U FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. o PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INN/ INVERTER(S) e METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). LSI T-VENT AC •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC DISCONNECTS) C7 SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC n DC DISCONNECT(S) FIRE SETBACKS •10.23 AMPS MODULE SHORT CIRCUIT CURRENT. •15.98 AMPS DEBATED SHORT CIRCUIT CURRENT(690.8(a)&690.8(b)). CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE r INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS A AMPERE sun run AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 s DC DIRECT CURRENT �,."' (E) EXISTING sm w sreearANOLSN VO,vNTON,MA02,eo-ra1 °` ESS ENERGY STORAGE SYSTEM FAX°1E0 al ' 1 EXT EXTERIOR WT°m INT INTERIOR CUSTOMER RESIDENCE: 4 MAG MAGNETIC ROBERT TEDESCO P v' MSP MAIN SERVICE PANEL 36 MAINE AVE,YARMOUTH,MA, •M (N) NEW 02673 NTS NOT TO SCALE OC ON CENTER TEL.(781)7078113 PRE-FAB PRE-FABRICATED APN:YARM-000022-000375 N PSF POUNDS PER SQUARE FOOT Q • 'Y" "" PV PHOTOVOLTAIC PROJECT NUMBER: f'•'..,., RSD RAPID SHUTDOWN DEVICE 223R-038TEDE Ti.. TRANSFORMERLESS 1 TYP TYPICAL DESIGNER: (415)580-6920 ex3 i V VOLTS NICHOLAS LIVELY r «a W WATTS SHEET i1• ' REV NAME DATE COMMENTS COVER SHEET sJ, t Q "a,.0 t REV:A 27/01/2022 PAGE PV-1.o 4 - L E - 2.2 - 00 14z., 3(2 fl 1(.ieie r,t< i I. ARRAY TRUE MAG PV AREA SITE PLAN-SCALE-3/32"a 1'-0" PITCH AZIM AZIM (SOFT) AR-01 23' 124° 138° 181.1 1'°J /..'........N'",..„... (E)DRIVEWAY -, Q;.; ° n R a Q, \ (E)RESIDENCE n a d. 4 a 4 -(N)ARRAY AR-01,� e��47 ° a 411114IPPAAPP .......‘‘...‘N. ,, WIPP i't .....Ns....N..,.....„,, At \At O R sunrun ,-0, / .....'...N...N.'7 cg I \ 48,e0,20 J \ / ,� 4' aearw1gaN e�w,rwrrou,MA,a:reo-r�ai PHONE\ FAX o CUSTOMER RESIDENCE: ROBERT TEDESCO g 362 MAINE73 AVE,YARMOUTH,MA, N. TEL.(781)707$113 / APN:YARM-000022-000375 R PROJECT NUMBER: 223R-038TEDE DESIGNER: (415)5806920 ex3 t d' NICHOLAS LIVELY SHEET \v/ SITE PLAN NOTE:ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE REV:A 27/01/2022 INSTALLED ON EACH MODULE PER NEC 690.12 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Detailg OC Spacing Overhang OC Spacing Overhang Configuration Span Spacing SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 8'-3" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: D1-AR-01-SCALE:1/4"■1'-0" 5/16"X 4.5":2.5"MIN PITCH:23° EMBEDMENT STRUCTURAL NOTES: AZIM:124° • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG {-3'-1" 1V-2" ••--'- 11.-6" --1V-2" 1,1111" REDUCED WITHIN THE 12" — 1 BOUNDARY REGION ONLY AS FOLLOWS: 1-6" ••ALLOWABLE ATTACHMENT 0 0 0 s. SPACING INDICATED ON 4'-10" PLANS TO BE REDUCED BY 50% r 1 ••ALLOWABLE OVERHANG TO 0 0 ❑ ❑ 0 0 0 0 S 9'-11" BE 1/C TATED H OFON ALLOWNABLE I ATTACHMENT SPACING INDICATED ON PLANS 6-7" ❑ 5 4" ❑ —� ❑ ❑ 0 ❑ s u n ru n _ 0 C) C) O O C) \ #180120 Ns MYLES STAND EN xw,TAINTON,MA.027e07331 PHONE" 3'-5" FAX o CUSTOMER RESIDENCE: ROBERT TEDESCO +— 36 MAINE AVE,YARMOUTH,MA, �ZH OF ass 02673 *''��SAMUEL �% TEL.(781)707-8113 O __BROWN, rn APN:YARM-000022-000375 , c-- -ei! '—ii PROJECT NUMBER: ca .0'0, r ° y 223R-036TEDE te DESIGNER: (415)380-6920 ex3 /oNAL NICHOLAS LIVELY Signed a.1/28/2022 SHEET LAYOUT REV:A 27/01/2022 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE OMETER#: EVERSOURCE 2282095 UTILITY GRID NEW 125A MAIN I PANEL ( NEW 100A 1 BREAKER --LOAD SIDE TAP J (N)LOCKABLE BLADE TYPE (N)MA SMART FUSED AC UTILITY DELTA ELECTRONICS: DISCONNECT REVENUE M4-TL-US I EXISTING 100A METER 3840 WATT INVERTER ,UNCTION BOX PV MODULES C SUB MAIN �� OR EQUIVALENT () JA SOLAR:JAM80377 325/MR BREAKER + 1// (10)MODULES o�.o. --r— O —y r— �, -..-= —.-- _T / (1)STRING OF(10)MODULES EXISTING 100A 20A FUSES ��• I f I (10)APSMART RSD-S-PLC MODULE SUB PANEL SQUARE D 240V METER SOCKET LOAD RATED DC LEVEL RAPID SHUTDOWN DEVICES D222NRB 100A CONTINUOUS DISCONNECT WITH AFC!, FACILITY 3R,80A UTILm SIDE OF CIRCUIT APSMART TRANSMITTER LOADS ..1......r. NOTE:TOTAL PV BACKFEED=20A 120/240VAC CONNECTS TO TOP LUGS- USED FOR INTERCONNECTION (LINE AT TOP LOAD AT BOTTOM) CALCULATIONS CONDUIT SCHEDULE GENERAL NOTES: 11 CONDUIT CONDUCTOR NEUTRAL GROUND •409 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE ' (1)10 AWG THHN/THWN-2 s u n ru n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 B SMVIEB BTNBNBII BIVO,TNNRON,IN 02110T331 NONE 0 FAX CUSTOMER RESIDENCE: ROBERT TEDESCO 36 MAINE AVE,YARMOUTH,MA, MODULE CHARACTERISTICS 02673 JA SOLAR:JAM80S17-325/MR: 325 W OPEN CIRCUIT VOLTAGE: 40.87 V TEL.(781)707-8113 MAX POWER VOLTAGE: 33.97 V APN:YARM-000022-000375 SHORT CIRCUIT CURRENT: 10.23 A PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 223R-O36TEDE SYSTEM SIZE: 3250 W SYSTEM OPEN CIRCUIT VOLTAGE: 455 V DESIGNER (415)580-8920 ex3 SYSTEM OPERATING VOLTAGE: 340 V NICHOLAS LIVELY MAX ALLOWABLE DC VOLTAGE: 800 V SHEET SYSTEM OPERATING CURRENT: 9.57 A SYSTEM SHORT CIRCUIT CURRENT: 12.79 A ELECTRICAL REV:A 27/01/2022 PAGE PV-4.0 INVERTER 1 NOTES AND SPECIFICATIONS: Al •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR -- IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 600 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) PHOTOVOLTAIC -7-�^ WARNING: PHO.J i O`lOLTAIC POWER SOURCE A.k LABEL LOCATION' INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, DUAL POWER SUPPLY AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. SOURCES:UTILITY GRID PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: 605.11.1.4 AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) CALJTION • DO NOT RELOCATE THIS MULTIPLE SOURCES OF POWER OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN OF RAPID SHUT DOWN / ' s u n r u n LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:890.58(Cx2),IFC \- ADJACENT TO PV BREAKER AND ESS 2012:805.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 4" — 705.12(BX3X2) }-, A SOLAR PV SYSTEM EQUIPPED #180120 005 MYLES STaroieH xw,TAUNTON,MM.02780,331 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN FM COMBINER PANEL DO NOT ADD LOADS — - SOLAR PANELS ON ROOF CUSTOMER RESIDENCE: ROBERT TEDESCO LABEL LOCATION: 36 MAINE AVE,YARMOUTH,MA, PHOTOVOLTAIC AC COMBINER(IF APPUCABLE). 02673 PER CODE(S):NEC 2020:705.12(DX2X3)(c) 3• TURN RAPID SHUTDOWN SWITCH TO THE"OFF' r 7;1 INVERTER(EXT) TEL.(781)707-8113 POSRIONTO SHUT DOWN -PRODUCTION METER APN:YARM-000022-000375 AN PV SYSTEM DISCONNECT PV SYSTEM DREDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT 16.00 AMPS 3HO "AZAR°INTME —AC DISCONNECT(INT) 223R-036TEDE ARRAY. 11111 NOMINAL OPERA I ING AC VOL IAGE: 240 VAC -AC DISCONNECT(EXT) DESIGNER: (415)580-8920 ex3 LABEL LOCATION: NICHOLAS LIVELY AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF —SERVICE ENTRANCE AND PVINTERCONNECTION. ' ' SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE BREAKER DISCONNECT SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. 36 MAINE AVE, YARMOUTH, MA, 02673 REV:A 27/01/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PER CODE(S):NEC 2020:705.10,710.10 PV-5.0