E-22-4443
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:7475W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), r SOLAR MODULES •MODULES:(23)JA SOLAR:JAM60S17-325/MR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. 111101 t o """" oi PV-2.0 SITE PLAN SE6000H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. LM J MAIN PANEL PV-3.0 LAYOUT TRACK ON COMP,SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-4.0 ELECTRICAL GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •EXISTING SOLAR SYSTEM INSTALLED. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SNR MOUNT 8 SKIRT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II LC PV LOAD CENTER !`,, CHIMNEY MODULES,ARE CLASS A FIRE RATED. •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL I� CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 8SUNRUN METER Ll ATTIC VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. l FLUSH ATTIC VENT •10.23 AMPS MODULE SHORT CIRCUIT CURRENT. PM DEDICATED PV METER •15.98 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)8 690.8(b)]. ,, PVC PIPE VENT •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(8)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INV INVERTER(S) o METAL PIPE VENT LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION T-VENT AC AC DISCONNECT(S) !-� T SATELLITE DISH O DC DISCONNECT(S) FIRE SETBACKS CB IQ COMBINER BOX HARDSCAPE E 7 INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE:NTS A AMPERE sun ru n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 r' (E) EXISTING A6 MYLES STANDMN ELM TAUNTON,MA,02730.7331 ESS ENERGY STORAGE SYSTEM PHONE E FAX0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: 1 MAG MAGNETIC CAROLYN MACLENNAN MSP MAIN SERVICE PANEL 31 N RD,YARMOUTH,MA,02673 (N) NEW NTS NOT TO SCALE ' .r✓ntn MA .1 OC ON CENTER TEL.(781)588.8696 3,NX2 w„1 U2b23 T. PRE-FAB PREFABRICATED PSF POUNDS PER SQUARE FOOT APN:YARM OW038-000073 9 PV PHOTOVOLTAIC PROJECT NUMBER: k. RSD RAPID SHUTDOWN DEVICE 223R-031MACL TL TRANSFORMERLESS 415 580-6920 ex3 ,O TYP TYPICAL DESIGNER: (V ) VOLTS 9- st-' o 0 W WATTS SHMANAN MATHUKIA EET e Q ir` 7, REV NAME DATE COMMENTS COVER SHEET REV:A 01/26/2022 a 1 PAGE PV-1.0 r .1 C----9 C.-De...---Z2 -©4C)4 q43 r L ARRAY TRUE MAG PV AREA SITE PLAN-SCALE■1/16'■1.-ir SITE PLAN DETAIL-SCALE■1/32"■1'-0" PITCH AZIM AZIM (SOFT) , AR-01 25° 304° 318° 380.2 , 7 :R-02 23° 304° 318° 36.2 (E)DETACHED STRUCTURE (E)PV EQUIPMENTS Q' R risv �® (E)GATE L i 80® 4- kL� (E)PATIO (E)RESIDENCE ♦ ` • O ♦♦ 4 , it 4 ,,. ♦♦® I,11�I,,10V (E)PV ARRAY ,,1 ,111'('lll'Il 11,1,�,,.�,, * , , 0114.,i;1111' 4 (E)DRIVEWAY /I ♦ ♦ .� �' �, i11�1111it1j1 (N)ARRAY AR-01 ♦ ♦ 4,1�,i111t,,t11�, �Ilp ♦ ♦ ���,���� sun run 40 R (E)FENCE (N)ARRAY AR-02 7 4180120 SIMILES STAMM PLVD,TAUNTON.MA 027E6f331 WOK 0 FAX U CUSTOMER RESIDENCE: CAROLYN MACLENNAN 31 N RD,YARMOUTH,MA,02873 TEL(781)588.8898 APN:YARM-000038-000073 PROJECT NUMBER: 223R-031MACL DESIGNER: (415)580.8920 ex3 MANAN MATHUKIA SHEET SITE PLAN REV:A 0126/2022 PAGE PV-2.O 1,1 INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR -----"" - IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON UNE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:890.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:890.13(B) Yil WARNING: PHOTOVOLTAIC IV t11PIO',;+^TIER SOURCE I LABEL LOCATION: Al• INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, DUAL POWER SUPPLY ON EVERY JS/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2020:690.31(DX2),IFC 2012: SOURCES:UTILITY GRID 605,11.1.4 AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. ` PER CODE(S):NEC 2020:705.12(C) - CAUTION : LABEL LOCATION: t1• INSTALLED WITHIN 3'OF RAPID SHUT DOWN SWITCH PER GIFC201:NEC 04.5.3 89o,58(C)(2),IFC MULTIPLE SOURCES OF POWER 2012:805.11.1,IFC 2018:1204.5.3 DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION; - z�, sun run ADJACENT TO PV BREAKER AND ESS OCPPER CODE(S);NEC202 SOLAR PANELS ON ROOF PER CODE(S): EC 2020: 4• 708.12(B)(3)(2) -'-� v Al SOLAR PV SYSTEM EQUIPPED -SERVICE ENTRANCE #180120 PHOTOVOLTAIC SYSTEM WITHRAPID SHUTDOWNON COMBINER PANEL / MAIN PANELEOEeBTgNDSMlLVO,TAUNON,Mq,021pR1131 DO NOT ADD LOADS FAX 0 (__ _ CUSTOMER RESIDENCE: 1 EXISTING PV EQUIPMENTS CAROLYN MACLENNAN LABEL LOCATION: PHOTOVOLTAIC AC COMBINER(IF AC DISCONNECT 31 N RD,YARMOUTH,MA,02673 APPLICABLE). PER CODE(S):NEC 2020:705.12(D)(2X3)(c) 3" TURN RAPID SHUTDOWN PV METER SWTf CH TO THE"OFF" «M! %/ / ///// // TEL.(781)588-8898 POSITION TO SHUT INVERTER(EXT) APN:YARM-000038-000073 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE //f///j`/j PROJECT NUMBER: SHOCK HAZARD MAXIMUM AC OPERATING CURRENT:25.00 AMPS N THE ARRAY. El 223R-031MACL NOMINAL OPERA I LNG AC VOL(AGE: 240 VAC DESIGNER: (415)580-0920 ex3 LABEL LOCATION: MANAN MATHUKIA AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. ` SHEET PER CODE(S):NEC 2020:890.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS 31 N RD, YARMOUTH, MA, 02673 ARE CONNECTED. REV:A 01/26/2022 PER CODE(S):NEC 2020:690.56(C) PER CODE(S):NEC 2020:705.10,710.10 PAGE PV-5.0 .! ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-1' 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-2" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 2-0" STAGGERED 5/16"x4.5":2.5"MIN COMP,SEE DETAIL SNR-DC-00436 EMBEDMENT STRUCTURAL NOTES: D1-AR-01•SCALE:1/8"■1'-0" • INSTALLERS SHALL NOTIFY PITCH:25° ENGINEER OF ANY AZIM:304° POTENTIAL STRUCTURAL -'3'-5" 22'-4" —5'-8"—{--- 16.-9" 6" ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING 3'-3" O SKIRT)IS WITHIN 12" 1 Millia_ I � • BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE 9'-11" ° �J � ADDED AND OVERHANG REDUCED WITHIN THE 12" MI' ���❑ BOUNDARY REGION ONLY • FOLL•ALLOWAB E ATTACHMENT 1,;9" SPACING INDICATED ON I PLANS TO BE REDUCED 4 BY 50% 3'S" 28' {-5'8"— 11'-2" J ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE -6" ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:IIB"..1'-0" sunrun PITCH:23° AZIM:304° 1'-4"—- —5'-7"— 41'-10" #180120 MS MULES STANOESt SIVO,TAUNTON,MA,02/004391 PHONES 1'-5" lit FAKO imp, I / CCAROLYN MACLENNAN ER RESIDENCE: 6'-7" i/i,�' i/�' __ 31 N RD,YARMOUTH,MA,02673 11= � wr i/i, �A i� Z���$1�MU ss'C TEL.(781)588-8696 �� For /'i,���� O --BROWN. L•- APR.JECTNUMB 000073 R:: 7' �� o Pi ->n'i PROJECT NUMBER: 9-.,'" 0. , 3 co 223R-031MACL q ' -- OST DESIGNER: (415)580.6920 ex3 KNAL MANAN MATHUKIA &pod on:1/2E,2022 SHEET LAYOUT REV:A 01/26/2022 PAGE PV-3.0 J r 120/240 VAC SINGLE PHASE SERVICE #: _ O METER ETER URCE29853I2 EXIS )NC SYSTEM UTILITY 1 <<nrt, GRID A' �r ,,a so 1 I m t.F, t; O I Ot � HA C !,_.. .. .,� nF(��� _ F�__ �� - _ _ _ ,_ t��__� �_,. tJI1� HANNHA(�i l LDS.GPPe G1+'CLS EXISTING 200A �1 1 r (4. ac.; BREAKER TOAD SIDE TAP --. �� ._.,. I v -. I I (N)LOCKABLE I EXISTING BLADE TYPE (N)MA SMART 200A MAIN FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: BREAKER DISCONNECT REVENUE SE6000H-USS3 1 METER 6000 WATT INVERTER JUNCTION BOX PV MODULES A OR EQUIVALENT A JA SOLAR:JAM60SI7-325/MR / (23)MODULES .�..�— e�.o. 1)) O `^ _ «—✓. —+— +(�.j// OPTIMIZERS WIRED IN: 35A FUSES I + I (1)SERIES OF(11)OPTIMIZERS EXISTING 200A SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT / • MAIN PANEL 3R,60A B 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS BOA uTIIJTY SIDE OF CIRCUIT COMPLIANT P370 FACILITY • — 120/240VAC CONNECTS TO TOP LUGS- � (LINE AT TOP LOAD AT BOTTOM) LOADS CONDUIT SCHEDULE CONDUIT CONDUCTOR NEUTRAL GROUND $u n ru n 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 me WWI nwne.e.VO,TAUNTON.Nu,O2/10.1e11 E EXISTING PHONE FAX CUSTOMER RESIDENCE: CAROLYN MACLENNAN 31 N RD,YARMOUTH,MA,02673 MODULE CHARACTERISTICS P370 OPTIMIZER CHARACTERISTICS: TEL(781)588-8696 JA SOLAR:JAM60S17-325/MR: 325 W MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.87 V APN:YARM-000038-000073 MAX POWER VOLTAGE: 33.97 V MAX INPUT VOLTAGE: 60 ADC PROJECTJECT NUMBER: SHORT CIRCUIT CURRENT: 10.23 A MAX INPUT ISC: 11 ADC 223R-031MACL MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 MANAN MATHUKIA SYSTEM SIZE: 7475 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 19.67 A REV:A 01/26/2022 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.O