HomeMy WebLinkAboutReview Checklist _ _Vlri`u,c. 4.0 c4 r ,,v,_(' ) Iosj eFOt-Pv 1(4 f/Cdi vt.
u
TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out Acreage
4;1 �'A00�
Street: 1 Commercial: Residential: X
Village: Floor Plan:
# Bedrooms:
Owner: Installer: T)
Address: Phone:
Phone:
Builder. ?L k /Yl c-Eii 4 mac
Engineer:
Address: Phone:
• Phone:
) N/A YES/ NO
1. Required# of copies received i
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table
4. Foundation 2 ft above highpoint of road
H.P.: Fnd: Var.: tr
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown - NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: f V✓ f II
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: J
9. Leaching minimum 100 ft from wetlands ,.
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓ -i
11. Tank/leaching minimum 10 ft from property Line Var.: ✓ I I
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: t/
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ! ✓
15. System not in topor subsoil l
(A,B horizons) or 5' removal � 1./7z,.
16. Proposed contours are suitable
* .System meets slope requirements - min. 1/8", V4" referred i I �I
18. '.ystem meets breakout requirements ✓ /
q PVC liner: Wall: � ✓
•. Specified tee sizes are proper, gas baffle on outlet tee
i
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal )
22. System adequately sized for its intended use
23. Minimum 6" stone or compacted below tank and dbox f ✓ 1 I
24. Manhole covers within 6"of grade, pump chamber cover to grade
2.. Inspection port on plastic chambers/leach field f )
Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2" line,weep hole,check valve, tee in dbox, pump size I ✓ I
28. Septic tank/pump chamber to be factory waterproofed I
)
29. Vent provided if leaching below 3 feet, under driveway/parking
30. Buoyancy calculations for tank/pump chamber ✓ " ✓/j
31. Engineer to inspect and certify soils: wall: commercial: ) ✓/
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓ 1
' . H-20 loading is subject to vehicular traffic, groundwater 1 I
34 Title V Application and permit fee, installer signature
5. Foundation footing min. 2 feet above adjusted ground water for new house -
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
1,7
Plan reviewed by: 0/03,03