Loading...
HomeMy WebLinkAboutEngineer PlanINSTALL 40 MIL POLY LIN TOP OF LINER, EL. -7.6 BOTT. OF LINER, EL. -5.6 EXISTING SHED REMOVE & RELOCATE stockade fence S.A. ir- PB 75 -PG 27 PROPOSED RET. WALL TOP OF WALL, EL=8.0 BOTT, OF BLOCK, SET AT 6.0 TP RESERVE AREA AREA REQUIRED = 445 SF 618 8 6.30. AREA PROVIDED = 454i. SF 7 PROPOSED SEPTIC TANK/ / 1 11 PUMP CHAMBER 6 OO EXISTING CESSPOOL v 1500/500 GAL CAPACITIES _ 14' „ TO BE PUMPED, FILLED o WITH SAND & ABANDONED n CONNECT TO EXISTING 6.65 SEWER OUTLET PIPE 6.67 AT HOUSE INV.=5.25 N PATIO n m -H 6.46 x (, io 7 d 6.69 6.95 {{ x / .BM." EXISTING 7 4a HOUSE(#79) T.O.F.=7.47f 41 FF EL.=8.31 x 6.98 6.96 6. 0 WALK a 10 ASS9Cy 6.76 1' (�rTi x R, PETER T. McENTEE O z CIVIL x 69 � 65 No. 35109 LOT 19 I'a 8712±S.F. j I Q 6.74 I •, $'' 60' 662 6.59 edge of pavement 6.44 6,32 FLOOD HAZARD DESIGNATION MAP NO. 25001CO589J EFFECTIVE DATE: JULY 16, 2014 ZONE AE(EL11) ELDRIDGE ROAD NOV 2 3 2020 HEALTH DEPT. x 100.98 EXISTING SPOT GRADE --1 ¢ --EXISTING CONTOUR -W- EXISTING WATER SERVIi -G- EXISTING GAS SERVICE /-(-`{ OVERHEAD WIRES ® EXISTING CESSPOOL TEST PIT 4 BENCHMARK GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING OM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN Yarmouth Health Department E GINEER BEFORE CONSTRUCTION CONTINUES. _-_ 5. A ELEVATIONS BASED ON NAVD88. Name OWNER OF RECORD ELAINE COUTURE 11 SEAVIEW DRIVE KINGSTON, MA 02364 6. T DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF LTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. Ito. W ER SUPPLY PROVIDED BY TOWN WATER SUPPLY. RE ARE NO WELLS WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR. OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH. CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. MAP ID: 25-159 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 79 ELDRIDGE ROAD, SOUTH YARMOUTH, MA Prepared for: Elaine Couture, 11 Seaview Drive, Kingston, MA 02364 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 290-20 12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0. Forestdole, MA 02644 E.Worehom, MA 02538 (508) 477-5313 (508) 273-0377 11/12/20 P.T.M. 1 Of 3 PROPOSED SEPTIC TANK PUMP CHAMBER / NOTE: TO PREVENT BREAKOUT, A 40 MIL POLY LINER PROPOSED D -BOX / SHALL BE INSTALLED AS SHOWN ON SHEET 1 PROVIDE RISERS WITH APPROVED FRAMES & COVERS VVV TOP OF LINER, EL =7.6 INSTALL WATERTIGHT RISER & OVER EACH ACCESS MANHOLE AND SET TO FINISH COVER SET TO 6" OF GRADE PROPOSED S.A.S. BOTTOM OF LINER, EL.=5.6 GRADE. MANHOLES BROUGHT TO GRADE SHALL BE SECURED TO PREVENT UNAUTHORIZED ACCESS. INSTALL INSPECTION PORT (MIN.) T.O.F.=7.47f F.G. EL: 8.5± F.G. EL.=8.5(MINJ F.G. illilillilirEL =6.5t F.G. EL=6.801 SUCK TOE UGH W'RE MAINTAIN 2% GRADE (MIN.) OVER S.A.S. / EXISTING ✓ 4 01AM INSPECTION PORT. _ `/ 2. PVC L = 8'(MAX) 15' x 30' LEACHING FIELD W/3-4` PERFORATED IN S.A.S., SOLID ® S�%('(�) TOP EL oanvi SGH R40 BLOCKS ® 5=1% (MIN.) SCH 40 PERF. PVC DISTRIBUTION LINES ABOVE S.A.S., WITH SCREW CAP P 4'SC H40 lc SET TO WITHIN �'_QF.. GRADE. 17777 �7= CAPPED ENDS TFP'S ARE TO BE ° ` J® ` I SLOPE OF PERF. PIPE = 0.5% INVERT a scH 40 PVC INV.=7.40 INV.=7.23 =4.70 e 30' EFFECTIVE LENGTH i ADJ. G.W. PROPOSED D -BOX a.e a coanu. G.W. EL. 1.5 3 OU�(MIN.) SOIL ABSORPTION SYSTEM (PROFILE) soTr. EL. -o.13 INV.=4.45± H-10 INV.=7.15 CONNECT TO (STING INV.=4.45 STG. G.W. EL. 0.6 SEWER OUTL FFLUENT F ER SHALL BE INSTALLED ON OUTLET -INV.=5.25± UFACTURED BY ZABEL OR EQUAL FILTER SHALL BE INSPECTED AND CLEANED ANNUALLY OR AS REWIRED TO PREVENT SEWAGE BACK UP. ESTABLISH VEGETATIVE COVER (See Pump Detail, Sheet 3 of 3) 1500/500 GALLON SEPTIC TANK/PUMP CHAMBER. FINISH GRADE EL.=8.5(MIN.) H-10 TANK NOTES: 1) SEPTIC TANK/PUMP CHAMBER & D -BOX SHALL BE SET LEVEL & TRUE TO GRADE ON A MECHANICALLY COMPACTED STABLE BASE, PER 310 CMR 15.221(2). 2) INSTALL INLET & OUTLET TEES AS REQUIRED, 3) MAX. COVER OVER TANK, D -BOX & S.A.S. SHALL BE 36". 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. DESIGN CRITERIA BREAKOUT ELEV.=7.50 BOTTOM ELEV.=6.50 5' MIN. SEPARATION TO G.W. AND 4'. OF NATURALLY OCCURRING PERVIOUS SOILS EST. HIGH G.W. EL: 1.5 - SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 2, DESIGN FOR 3 SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD / GARBAGE GRINDER: NO J LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF PROPOSED SEPTIC TANK/PUMP CHAMBER: 1500/500 GAL., H-10 PROPOSED D -BOX: 1 INLET, 3 OUTLET (MIN.), H-10 INSTALL AN 15' x 30' LEACH FIELD SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: 15' x 30' = 450 S.F. TOTAL AREA:....................................450, S.F. LEACHING CAPACITY = 0.74 GPD/SF x 450 SF 333.0 PD 15' EFFECTIVE WIDTH SOIL ABSORPTION SYSTEM (SECTION( EL.=7.00(END) APPROVED FILTER FABRIC SOIL LOG DATE: OCTOBER 7, 2020 SOIL EVALUATOR: PETER McENTEE PE, SE -1542 WITNESS: MALLORY LANGLER HEALTH AGENT ELEV. TP DEPTH 6.3 A /A 0" 5.9MOYR4/25„PERC 12"/30" 3.6 32" MED. SAND 2.5Y 5/3 1.5 ADJ. G.W. - 58" (58"-62" redox) 0.6 STG. G.W. _ 68" 7.5YR 5/8 0.1 74" PERC RATE 2 MIN/IN. ("B" HORIZON) STANDING G.W. @ 68" (EL.=0.6) ESTIMATED HIGH GROUNDWATER, EL.=1.5 (REDOX) 1/2 -DOUBLE STONE RINSE I v�' ^ Go I M dam- _ y S (a O ' '9. CA. Ini PROPOSED �I S.A.S. I-30'-- I G WALL DIM L ONCRETE BLOCK GRAVITY WALL ONE LIFT OF BLOCK e 2' deep x 2' wide x 3', 4" or 6' long Falmouth Ready Mix, or equal SEPTIC LAYOUT PROPOSED SEPTIC SYSTEM UPGRADE PLAN 79 ELDRIDGE ROAD, SOUTH YARMOUTH, MA Prepared for: Elaine Couture, 11 Seoview Drive, Kingston, MA 02364 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. JC Engineering, Inc. N.TS. P.T.M. 290-20 12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0. Forestdale, MA 02644 E.Warehom, MA 02538 (508) 477-5313 (508) 273-0377 11/12/20 P.T.M. 2 of 3 PROVIDE WATERTIGHT CONCRETE RISER SECURED FRAME & COVER TO GRADE HOISTING CABLE 7x19 STAINLESS STEEL 1/8" DIAMETER. / 1,760 LB. STRENGTH.--- (TO TRENGTH.---(TO BE INSTALLED IF QUICK DISCONNECT IS NOT INSTALLED) INV.(IN)=4.45 ALARM ON EL: 2.13 PUMP ON EL: 1.80 PUMP OFF EL: 1.13 LIv 1116" BOTTOM OF PUMP CHAMBER 8 ELEV.= 0.13 PROVIDE 2 FLOATS: 4 FLOAT NO.1: PUMP ON/OFF—SJ RHOMBUS (PROVIDED WITH PUMP) FLOAT NO.2: ALARM ACTIVATION FLOAT—PROVIDED WITH ALARM PANEL (ON SEPARATE CIRCUIT FROM PUMP SPECIFIED) NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID—TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT. AN SJE RHOMBUS—JB PLUGGER OR EQUAL IS RECOMMENDED. PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) (INSTALL QUICK DISCONNECT FOR EASY REMOVAL) 2"SCH. 40 DISCHARGE (THROUGH RISER—SEE PROFILE) 2" 90' ELBOW W/ 1/4" WEEP HOLE FOR SELF—DRAINING FORCE MAIN 2" SWING CHECK VALVE 2" SCH. 40 PVC DISCHARGE PIPE ADDITIONAL 3/16" VENT HOLE (MIN:) ABOVE PUMP FLANGE (TO PREVENT PREMATURE PUMP BURNOUT) LIBERTY LE40 SERIES PUMP .4 H.P. 115 V WITH 2" DISCHARGE, OR EQUAL PUMP CHAMBER, PUMP & ACCESSORIES AVAILABLE AS A UNIT CAPE WINWATER WORKS CO., HYANNIS, MA. (508) 862-0166 NOTE: APPROVED ALTERNATE MAY BE SUBSTITUTED. PUMP DETAIL N.T.S. 20" DIA. COVERS (TYP.) FIm-i FT TT Li A II II A rD II II �---��_j 4" KNOCKOUTS (TYP.) 5'-8 4" PLAN VIEW 20" DIA. COVERS (TYP.) CROSS SECTION WT. of H-10: 18,852 LBS. SPECIFICATIONS 1.) CONCRETE 4,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. 310 CMR SECTION 15.226. ENTRY 3.) TONGUE & GROOVE JOINT SEALED W/ BUTYL RESIN 4.) REINFORCEMENT PER ASTM C1227-96. 5.) ALSO AVAILABLE IN H-20 LOADING. L- fi�RVIDEPOLYMER WATERPROOF COATING H-10 SEPTIC TANK/PUMP CHAMBER 1500/500 WIGGIN PRECAST CORP., BOURNE MA. (800) 564-6774 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 79 ELDRIDGE ROAD, SOUTH YARMOUTH, MA Prepared for: Elaine Couture, 11 Seaview Drive, Kingston, MA 02364 BUOYANCY CALCULATIONS I/ CL. I CL. H-10 SEPTIC TANK/PUMP CHAMBER REQUIREMENTS BOTTOM OF UNIT EL.= 0.13 HIGH GROUNDWATER EL.=1.50 DESIGN FLOW: BUOYANCY FORCE PER FOOT OF DEPTH: UTILIT) 12.2' x 6.7' x V x 62.4 lbs./cu.ft. = 5100.6 lbs. sHEO MAX. DISPLACEMENT = 1.50' — 0.13' = 1.37' DATE MAX. UPLIFT PRESSURE = 1.37' x 5100.6 lbs/ft = 9573.3 lbs. 330 - 4 = WEIGHT OF UNIT EMPTY = 18,852 lbs. BATH 18,852 lbs > 9.753 lbs O.K. BEDROOM KITCHEN 20" DIA. COVERS (TYP.) FIm-i FT TT Li A II II A rD II II �---��_j 4" KNOCKOUTS (TYP.) 5'-8 4" PLAN VIEW 20" DIA. COVERS (TYP.) CROSS SECTION WT. of H-10: 18,852 LBS. SPECIFICATIONS 1.) CONCRETE 4,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. 310 CMR SECTION 15.226. ENTRY 3.) TONGUE & GROOVE JOINT SEALED W/ BUTYL RESIN 4.) REINFORCEMENT PER ASTM C1227-96. 5.) ALSO AVAILABLE IN H-20 LOADING. L- fi�RVIDEPOLYMER WATERPROOF COATING H-10 SEPTIC TANK/PUMP CHAMBER 1500/500 WIGGIN PRECAST CORP., BOURNE MA. (800) 564-6774 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 79 ELDRIDGE ROAD, SOUTH YARMOUTH, MA Prepared for: Elaine Couture, 11 Seaview Drive, Kingston, MA 02364 Engineers: CL. I CL. DOSING & STORAGE REQUIREMENTS JOB. NO. Engineering Works, Inc. DESIGN FLOW: 330 GPD P.T.M. BEDROOM LIVING ROOM DOSING REQUIRED: 4 CYCLES/DAY (SAND) DATE 330 - 4 = 82.5 GALLONS/CYCLE E.Warehann, MA 02538 DISTANCE REQUIRED BETWEEN PUMP SHEET N0. (508) 477-5313 ON AND PUMP OFF FLOATS: P.T.M. 3 Of 3 82.5 GAL/CYCLE - 125 GAL/FT = 0.66 FT/CYCLE (USE 8") ENTRY STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: FLOOR PLAN INV.(IN) EL: 4.45 — PUMP ON EL: 1.80 = 2.65' FOR SCHEMATIC PURPOSES ONLY STORAGE PROVIDED = 2.65' x 125 GAL/FT = 331.2 GALLONS 20" DIA. COVERS (TYP.) FIm-i FT TT Li A II II A rD II II �---��_j 4" KNOCKOUTS (TYP.) 5'-8 4" PLAN VIEW 20" DIA. COVERS (TYP.) CROSS SECTION WT. of H-10: 18,852 LBS. SPECIFICATIONS 1.) CONCRETE 4,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. 310 CMR SECTION 15.226. ENTRY 3.) TONGUE & GROOVE JOINT SEALED W/ BUTYL RESIN 4.) REINFORCEMENT PER ASTM C1227-96. 5.) ALSO AVAILABLE IN H-20 LOADING. L- fi�RVIDEPOLYMER WATERPROOF COATING H-10 SEPTIC TANK/PUMP CHAMBER 1500/500 WIGGIN PRECAST CORP., BOURNE MA. (800) 564-6774 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 79 ELDRIDGE ROAD, SOUTH YARMOUTH, MA Prepared for: Elaine Couture, 11 Seaview Drive, Kingston, MA 02364 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. JCEngineering, Inc. N.TS. P.T.M. 290-20 12 West Crossfield Road 2854 Cranberry Hwy. DATE Forestdole, MA 02644 E.Warehann, MA 02538 CHECKED SHEET N0. (508) 477-5313 (508) 273-0377 11/12/20 P.T.M. 3 Of 3