HomeMy WebLinkAboutRevised Site Plan 2-pg set 3-2-22LEGEND
LAialIINU UUrviUUM
X 99. 1
EXIST. SPOT ELEV.
-[99]-
PROPOSED CONTOUR
198.41
PROPOSED SPOT EL.
TH1
TEST HOLE
2YYY%�
SLOPE OF GROUND
UTILITY POLE
FIRE HYDRANT
NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING
THE YARMOUTH BOARD OF HEALTH SHALL REQUIRE THE FOLLOWING INSPECTIONS:
1. INSPECTION OF UNSUITABLE MATERIAL (IF ANY).
2. VERIFICATION OF SOIL CONDITIONS AND/OR GROUNDWATER ELEVATION (IF NECESSARY)
3. VERIFICATION OF CESSPOOL/LEACH PIT REMOVAL OR ABANDONMENT (IF NECESSARY)
4. INSPECTION OF CONTAINMENT WALL OR FLOW BARRIER INSTALLATION (IF ANY)
5. INSPECTION OF THE 3/4 - 1 1/2 INCH STONE PRIOR TO PLACEMENT
6. FINAL INSPECTION OF ALL COMPONENTS PRIOR TO BACKFILLING
7. FINAL GRADING INSPECTION
8. INSPECTION OF THE START-UP OF INNOVATIVE/ALTERNATIVE TECHNOLOGY (IF ANY)
WITH VENDOR REPRESENTATIVE
RIVERFRONT
MITIGATION CALCULATIONS:
HARDSCAPE 0-100'
100-200'
EXISTING:
3490 SF
3305
SF
PROPOSED:
3005 SF
8705
SF
CHANGE:
-485 SF
5400
SF
REQUIRED
MITIGATION :
4915*2 =
9830 SF (9,850
SFf PROVIDED)
JDCE #21-158
TEST HOLE LOGS -
ENGINEER: CRAIG J. FERRARI, SE #13871
WITNESS- CAROL EASTMAN
DATE: 1 1 /29/21
PERC. RATE _ < 2 MIN/INCH
CLASS I SOILS
4 ELEv
0" i 5'
A
LS
14" 1OYR 4/1
B
LS
30" 10YR 4/6 2 5,
PERC
C
MS
2.5Y 7/6
SLAB EL. 6.7'
*7.7'
*THE INSTALLER SHALL VERIFY THE
LOCATIONS OF ALL UTILITIES AND ALL
BUILDING SEWER OUTLETS AND
ELEVATIONS PRIOR TO INSTALLING ANY
PORTION OF SEPTIC SYSTEM
4 ELEV.
2 6'
0"
A
LS
18" 1OYR 4/1
B
LS
1OYR 4/6
30" 3.5'
96" I I -3' 96"
G-W ADJ. DATA: GROUNDWATER AT 48"
WELL: MIW 29 ELEVATION 1.0'
ZONE: A
ADJ: 1.5'
DECEMBER 2021
C
MS
2.5Y 7/6
PROVIDE MIN. 20" DIAM. WATERTIGHT
ACCESS COVERS TO GRADE
12.2'
MINIMUM .75OF COVER OVER PRECAST
PRECAST H-10
RISERS (TYP.)
2'0
ZABEL A100
10" FILTER PRIOR
7.25' TEE To P/C
H-20
2000 GAL LOW PROFILE
SEPTIC TANK
4' LIQ. LEVEL (ACME OR EQUAL)
JOO O O O O` 0 •0; O •O O O O O•O O• 0 0 O0 0 0
• 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0000000000000000000000000000000000000000000
0 0 0 0 �.�_�_�_n_o.o 0
FOUNDATION
ALARM AND CONTROL PANEL
TO BE INSTALLED INSIDE
BUILDING. ALARM TO BE ON
SEPARATE CIRCUIT FROM PUMP
PRECAST H-10
RISERS (TYP.)
PROVIDE MIN. 20" DIAM. WATERTIGHT
ACCESS COVERS TO GRADE
10.0' MINIMUM .75' 1OF COVE
PRECAST
SYSTEM PROFILE
(NOT TO SCALE)
6" MIN. SUMP
12" MIN. INT. DIM.
H-20
1a" 2000 GAL EE
6.96' TEE PUMP CHAMBER
C, o .o oOOOo°
SEE DETAIL BELOW ?00 00°0 0°
8.62'
JOO O O O Or 0 •O O •O O O O O••O O' 0 0 0 O O O't
.000
o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
000000000000000000000000000000000000000000000
,,o„o_�_n_n_o_o 0 0 0 0 0 0.�_�_no.0 0-
6" CRUSHED STONE OR MECHANICAL 6" CRUSHED STONE OR MECHANICAL
COMPACTION. (15.221 [2]) COMPACTION. (15.221 [2])
( 2.5 % SLOPE) ( 2 % SLOPE)
- 15' SEPTIC TANK 2' PUMP CHAMBER 90' D' BOX
PROP. WATERTIGHT COVER TO GRADE SYSTEM DESIGN:
PROVIDE QUICK DISCONNECT FOR PUMP
INV. IN 6.96'1 11 NO LOW POINTS
-Z 2000 GAL. H-20 S/ 2" PRESSURE LINE ALARM ON ON 1245 GAL. SLOPE TO DRAIN BACK TO PC
FLOAT SWITCH RESERVE
SETTINGS: PUMP ON 0.25" WEEP HOLES
$„ CHECK VALVE
4" WORKING RANGE MYERS SRM 4
4" SUBMERSIBLE 4/10 HP PUMP
PUMP OFF 12" SYSTEM (OR EQUAL)
000 0
000000 000000000 0 0 0000
PUMP CHAMBER
(NOT TO SCALE)
WATERPROOF/WATERTIGHT
MAP 34 PARCEL 292.1
JOSEPH GILMORE
nrn-r nncnnn
4"OSCH40 PVC
PIPES LEVEL 1 ST 2'
WATERTEST D'BOX
FOR LEVELNESS
r-. . - 1
(1 % SLOPE)
12' -
GARBAGE DISPOSER IS NOT ALLOWED
#181 EXISITNG 6 BEDROOMS
#183 EXISTING 3 BEDROOMS
DESIGN FLOW: 9 BEDROOMS ® 110 GPD = 990 GPD
USE A 990 GPD DESIGN FLOW
SEPTIC TANK: 990 GPD (2) = 1980
USE A 2000 GAL. SEPTIC TANK
AND A 2000 GAL. PUMP CHAMBER
LEACHING:
990 GPD / (.74) = 1338 SF REQUIRED
25' X 54' = 1350 SF OK
1350 SF X .74 = 999 GPD OK
USE A 25' X 54' PIPE AND STONE LEACHING FIELD
MARK CORNERS OF
LEACHING FIELD W/ PROVIDE INSPECTION PORTS TO
REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE
GRADE 2% SLOPE
FILTER FABRIC -
/Cs
5 TOP 8.68' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ.
z 'All
CLEAN FILL
e PERFORATED PVC 5' O.C. S=0.005 -- 0
0
3/4"-1-1/2" DOUBLE WASHED 0
lollSTONE LEACHING FIELD 6"DEPTH MIN BELOW INV.
LEVEL BOTTOM 0 8.0'
54.0'
1 7.5'
5.0'
ADJUSTED GROUNDWATER 2.5'
LEACHING BUOYANCY CALCS:
FACILITY H-20 2000 GAL. PC WEIGHS 26,000 LBS
1.64' x 6 x 11 x 62.4 = 6,755 LBS UP (OK)
H-20 2000 GAL. ST WEIGHS 26,000 LBS
1.33' x 6 x 11 x 62.4 = 5,478 LBS UP (OK)
ZONING SUMMARY
ZONING DISTRICT: RS-40 RESIDENTIAL DISTRICT
REQUIRED: EXISTING: PROPOSED:
MIN. LOT SIZE 40,000 S.F. 85,850 S.F. 85,850 S.F.
MIN. LOT FRONTAGE 150' 149.94' 149.94'
MIN. FRONT SETBACK 30' 289' 318'
MIN. SIDE SETBACK 20' 14.6' 23.6'
MIN. REAR SETBACK 20' - -
MAX. BUILDING COVERAGE 25% 6.0% 6.9%
MAX. BUILDING HEIGHT 35'
o \eo50 �
o'
Q
ornin �
�OwSt.
o
lb z
1> Nro
?
LOCU
5 �
� a
P a
a
Sh°re
th Dr.
Nantucket
Sound
LOCUS MAP
SCALE 1 "=2000'f
ASSESSORS MAP 34 PARCEL 292.2
LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 11)
& VE (EL 13) AS SHOWN ON COMMUNITY PANEL
#25001 CO589J DATED 7/16/2014
PROPOSED DWELLING IS WITHIN AE (EL 11)
DESIGN FLOOD ELEVATION 12.0
NOTES
1. DATUM IS NAVD 88
2. MUNICIPAL WATER IS EXISTING
3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT.
4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO
BE AASHO H-?-O
5. PIPE JOINTS TO BE MADE WATERTIGHT.
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH
310 CMR 15.000 (TITLE 5.)
7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO
BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE.
8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC.
9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED
WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION
OBTAINED FROM BOARD OF HEALTH.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING
DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION
OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO
COMMENCEMENT OF WORK.
11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE
REMOVED BENEATH AND 5' AROUND THE PROPOSED
LEACHING FACILITY.
12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND
REMOVED OR PUMPED AND FILLED WITH CLEAN SAND.
13. POOL FENCE SHALL HAVE SELF -CLOSING
SELF -LATCHING GATES, SIZE AND MATERIALS TO MEET
LOCAL AND STATE BUILDING CODE, ALL DWELLING DOORS
OPENING TO POOL SHALL BE ALARMED TO CODE.
14. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS.
WATER RESISTANT CONSTRUCTION UP TO ELEVATION 12.0.
15. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO
DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES.
16. ACCESS FOR ROUTINE MAINTENANCE MUST BE
PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW
MANUFACTURER'S SEPCIFICATIONS FOR PROPER FILTER
INSTALLATION.
17. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS
SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT
REQUIRED.
lit
''I W�ii
OF
y
y #150 SOUTH STREET
v
" o
L y y SOUTH YARMOUTH, MA_
PREPARED FOR
JOSEPH GILMORE
DATE: JAN UARY 13, ' 2022
REV. MARCH 2, 2022
Scale:1 "= 20'
.F
OFMgss4 ��y1NCh1gs- .L J/7-
DANIEL 9cy°DANIELA. chG� 0 10 20 30 40 50 FEET
1� A + o OjALA __4 off 508-362-4541
o OJALA � c
CIVIL
No. 40980 Na 46502 fax 508-362-9880
��Ln downcape.com
OPE55�0 O�F`,c JSTER G�� • • •M/�
VE TONAL EN MOWII CQ.la e# Illeefi' f, 14C.
civil engineers
2JI2/ZZ -�� land surveyors
939 Main Street ( Rte 6A)
DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675
DCE #21-158
K
AME
AME
PLA
MA1
ANC
OWN
THE
PRI(
2)
DET
OF
SOIL
EXC
3)
WA1
WA1
EST
4)
THE
FINi
WTI
INCL
SIMI
CON
5)
SHR
J D CE
o \e o .4
5 0�0
arnin
Qj
aS 0
�owSt.
0
c
� LOCU
Z
Dr.
Nantucket
Sound
L 292.2
_ACE BALL ON SUBSOIL. REMOVE AND
SCARD BURLAP EXCEPT UNDER BALL.
-MOVE ALL SYNTHETIC SOIL WRAPPING
ATERIALS (TREATED BURLAP, NYLON TWINE,
IRE BASKETS, ETC.) AND DISCARD
(CAVATE SUBSOIL AS REQUIRED TO PLACE
DOTBALL TO PROPER ELEVATION. PLACE
DOTBALL DIRECTLY ON SUBSOIL
(CAVATE HOLE TO DIAMETER 3X WIDER THAN
DOTBALL. BACKFILL HOLE WITH PLANTING SOIL
X AS SPECIFIED
' BARK MULCH, AS SPECIFIED
UNDISTURBED SUBGRADE
'ITREET
JTH, MA_
2
25 FEET
off 508-362-4541
fax 508-362-9880
downcape.com
ape edgineefing, iac.
civil engineers
land surveyors
lain Street ( R to 6A)
VOUTHPORT MA 02575