HomeMy WebLinkAboutTitle 5 Site Plan 3-15-22in LEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. --[99]- PROPOSED CONTOUR PROPOSED SPOT EL. TH1 0 TEST HOLE 2% SLOPE OF GROUND Cob UTILITY POLE ' 10 FIRE HYDRANT NOTE: ` NOT ALL SYMBOLS MAY APPEAR IN DRAWING SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS 0 110 GPO = 440 GPD \ SYSTEM PROFILE MARK CORNERS OF LEACHING FIELD W/ (� TO � GRADE E SET 4" BELOW INSPECTION PORT 27 SLOPE FILTER FABRIC USE A 440 GPD DESIGN FLOW 23.0' MINIMUM .75' OF COVER OVER PRECAST 23.0-25.0 ,TOP 22.0' FINISHED GRADE- 4" LOAM &SEED .: RISERSPRECAST MP.) WATERTEST O'BOX SEPTIC TANK: 440 GPD (2) = 880 2•e FOR LEVELNESS 4"•SCH4o PVC %. :.�< Alm , PIPES LEVEL 1ST 2' i CLEAN FILL > * USE A 1500 GAL. H-10 SEPTIC TANK 10 IWO GAL H-10 14- a PERFORATED PVC 3-W O_C_ S=0.005 -� O 21.2' TEE SEPTIC TANK TEE >�. a LEACHING: z�eEt �� 20.95 000000000000 `�/ 3/4"-1-1/2" DOUBLE WASHED o ���� o 0 0 o a o �/ 8" STONE LEACHING FIELD 6"DEPTH MIN BELOW INV. 440 GPD .74 = 595 SF REQUIRED " • aacroa a_ ( ) •• • � • � ounFr ,� w�tx►orsioN 20.57' 2 .4' � � 20.15' :3 • : 4 UQc LEVEL (ACME OR EQUAL) 20.37 LEVEL BOTTOM O (12.5 X 26) + (10 X 31) = 635 SF OK .!• o�aaco'ua'oaaauaaaaaaaace�a ���T.'i �'�C�1CC��r�:'T:'' •'aaaaa�aaaaaaaaaaaaaaaaa�aaaaaaaaa"�aaaaaaaoa 635 SF X .74 = 470 GPD OK 43.5' USE A PIPE AND STONE LEACHING FIELD IN CONFIGURATION SHOWN. 19.65' (SEE LEACHING DETAIL) 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND (2.5z SLOPE) (1 % SLOPE) (-!-X SLOPE) **ADJ. G.W. EL= 14.65' ELEVATIONS PRIOR TO INSTALLING ANY LEACHING PORTION OF SEPTIC SYSTEM FOUNDATION- 30' SEPTIC TANK 38' D' BOX 5' FACILITY *4-0'�N GAS LINE o OPOSED CLEARING LIM RELOCATED ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FNDN. EL. 25.0' L FENC 14) 4 SEPTIC TANK � � ■ I� P,7jN1OPOSU1,.' WORK • HE0 co f R MOVE/REVEGETATE) 7 f LL �N FocF p, , ® .F. � ° - -- o f f of 20•5' P% E oq, O j Q o f.00 .. ... ° P POSED WILDFLOWER CIVF i ITIG TI N PLANTINGS ''' o ci i+ + 4 o J Q 4.4 j a_ + + cv EXISTING 3 BR +. ` DWELLING TOP w - _ +� I -W OF FNDN EL. •a.". i 16�'- ; -7;' + + > a �� W W 25.0' _ �� '0}C'qh 0� + + + + j I PROPOSED PROP. . _ _ ••• .•••,•••_•1• •�.' + + PORCH STAIR 1 + o,m III II •�, 32js (SONOTUBES) 7.5' _' ; + + ", :� 00 ,r DEM r + + EXIST. 1 1 1 1 �J 1 DECK + + o 1 1 i1 C� GARAGE j1 + + + 0 N N SLAB EL - + + x o 24.0 + + b 24 PROP. "' `X --- x TH- STAIR o PAV � o •� IVE \ LOT 62 �o 21,880f SF } d BENCHMARK: ' 117.00 C4 MAG SET =23.8' NAVD88 LOO ko FOLAG ut O a d ; APP CO EA� DE 0 EXISTING NCE 0 E 0 R GETATE) A., REPLACE WI o', S I L FFNCE ECTION S.F OOL FENCE (S NOTE 14) o? DCE #21-079 VARIANCES REQUESTED UNDER YARMOUTH BOH SUB -SURFACE SEWAGE DISPOSAL REGULATIONS: -REDUCTION TO GROUNDWATER ADJUSTMENT OF 0.55' (0.7' TO 0.15')** 26.0' rri 10.0' LEACHING DETAIL (SCALE: 1 "= 10') NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. Loc 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS ( �fl� TO BE AASHO H-]Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. C 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) a 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. Rte BQ 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCUS �A� LOCATION OF ALL UNDERGROUND do OVERHEAD UTILITIES L u PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE SCALE 1 "=2000'f REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. ASSESSORS MAP 149 PARCEL 75 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND LOCUS IS WITHIN FEMA FLOOD ZONE X REMOVED. (AREA OF MINIMAL FLOOD HAZARD) AS 13. WETLAND FLAGGED BY BRAD HALL OF BLH SHOWN ON COMMUNITY PANEL #25001 CO576JDATED 7/16/2014 ENVIRONMENTAL CONSULTING 14. POOL FENCE TO BE INSTALLED AS PER STATE AND LOCAL POOL REGULATIONS. PROVIDE DOOR ALARMS AND SELF LATCHING GATES AS REQUIRED. 15. REFERENCE ORDER OF CONDITIONS SE # 083-2323 ZONING SUMMARY TEST HOLE LOGS TEST HOLE LOGS ZONING DISTRICT. R-40 DISTRICT ENGINEER: DAVID FLAHERTY, R.S., SE2755 ENGINEER: CRAIG J. FERRARI, SE #13871 REQUIRED: EXISTING: MIN. LOT SIZE 40,000 S.F. 21,880 S.F.f WITNESS: AMY VON HONE, R.S., C.H.O. WITNESS: PHIL RENAUD MIN. LOT FRONTAGE 150' 286► DECEMBER 10, 2008 2 2022 DATE: 3 / / MIN. FRONT SETBACK 30' 27.6' .DATE: MIN. SIDE SETBACK 20' 41.9' PERC. RATE _ < 2 MIN/INCH PERC. RATE _ < 2 MIN/INCH MIN. REAR SETBACK 20' I MAX. BUILDING COVERAGE 25% 11.6% CLASS I SOILS CLASS SOILS MAX. BUILDING HEIGHT 35' <35' PROPOSED BUILDING COVERAGE 12.8% 4 21.0' ELEV. n ELEV. 0„ a„ `V' 23.0 0/A/E A LS LS ., 7 10YR 4/2 10YR 3/2 9„ B B LS LS 27" 10YR 5/6 18.7' 10YR 5/8 18" 21.5' C PPERCC VN MSPERC MIS LO N 1OYR 7/4 OBS. WELL INFO- GROUNDWATER ADJ. DATA: 2.5Y 7/4 WELL- SDW-252 14.5' WELL: SDW 252R ZONE- A ZONE: A DATE 0 ADJ G W - N VEMBER 2008 " ADJ. G.W. 96 13.0 ADJUSTMENT: 0.7 14.5, READING- 47.4' (FEBRUARY '22) =13.0- ADJUSTMENT 1.5' 108" G.W. 12.0'120" G.W ENCOUNTERED AT 102" EL. 14.5' TITLE 5 SITE PLAN OF 84 HOMERS DOCK RD. YARMOUTH PORT, MA PREPARED FOR BECKY & ALBERTO MAITINO DATE: MARCH 15, 2022 �o� DANIEL yGN Scale: 1 = 20 DANIEL A. �� A. Z O.ir"-.LA �� . OjALA o CIVIL .' No.40980 0 10 20 30 40 50 FEET No. d6502 4oF E s s� off 508-362-4541 G I s 7 �R� �� ' �/'o Su R ! Ey fox 508-362-9880 �,S/ONAL EN�'\ y a downcope.com we cope OfffAV f, AM civil engineers land surveyors 1 939 Main Street ( R to 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 21-079 MAITINO (2).DWG