Loading...
HomeMy WebLinkAboutPD500_AC_25sept19PD500/AC-480 500 kW Energy Storage Inverter Reliable service in the most demanding applications Engineered to provide years of reliable service in the most demanding applications. EPC’s advanced smart inverters for energy storage will enable you to deploy scalable power conversion systems with less effort and in less time. Integrating 1,000 V class battery energy storage systems has never been easier or more compact. With world-class power density and an easy to install design, your energy storage system will be up and running in no time. This inverter is designed from the ground up with simplicity, reliability, and scalability in mind. The liquid- cooled inverter includes an integrated AC contactor, AC breaker, DC contactor, and precharge circuit, enabling simple installation. The PD500/AC-480 provides reliable, abundant power in a small footprint for years of reliable service. Bidirectional Inverter • THD <2% • 1250 VDC • Peak efficiency 98.4% • 50 & 60 Hz operation • Grid-tie and off-grid • Parallel UPS backup • Real and reactive power control • Fully bidirectional • Single-phase capable PD500/AC-480 Bidirectional Energy Storage & Microgrid PCS 13250 Gregg Street, Suite A-2 | Poway, CA 92064 | 1.858.748.5590 | epcpower.com AC AC port configuration IP2W or 2P2W | 3P3W AC voltage range 480 VRMS +10% / -12% AC export power @ 60°C inlet 500 kVA | 603 ARMS AC import power @ 55°C inlet 500 kVA | 603 ARMS Overload capacity 110%, 10 minutes | 125%, 10 seconds AC high voltage ridethrough 1.2 pu Maximum grid impedance 8%, 500 kVA base Nominal frequency range 50 - 60 Hz (field settable) Harmonic distortion UL1741/IEEE 1547, <2% TDDi per IEEE 519 Power factor / reactive power Maximum aux. power consumption 750 W (includes ext. cooling pump + fan) CEC efficiency 98.0% Peak DC to AC efficiency 98.4% DC DC voltage range 710 - 1250 VDC Maximum DC current 750 ADC Battery technology all battery types, fuel cells, other DC sources, etc. Number of DC inputs 1 Environmental Ambient temperature (operation) -20°C to 50°C Ambient temperature (storage) -20°C to 50°C Protection degree IP00 (requires enclosure) Relative humidity 5% - 95% non-condensing Max elevation 2,000 m [6,500 ft.] Airborne noise <75 dBA @ 1m Temperature de-rating automatic; see charts Cabinet Maximum dimensions (H x W x D)mm: [670 x 530 x 1045] | Weight 328 kg [725 lb.] Mounting rack mount Cooling liquid Cooling fluid 30% - 50% EWG or PWG Certifications Safety UL 1741 | C22.2 No. 107.1-16 Utility interconnect Source SRD UL 1741:2010 R2.18 (SA) | IEEE 1547.1-2003 & 1547.1-2015 | CA Rule 21 No. 16-06-052 | Hawaii Rule 14 No. 2014-0192 Protections AC protection Breaker; 35, 50, 65, 100 kA Isc options DC protection DC contactor & precharge; ext. fusing required Humidity by customer Safety features overvoltage, overcurrent, overtemperature Ground fault detection not included Control Control interface CAN, Modbus RS485, or Modbus TCP Command latency 1 ms Response time; e.g. step from full charge to discharge 20 ms; adjustable longer via parameters Black-start capable Yes; requires external control power Grid-tied control modes PQ (power) | DQ (current) | cos phi (pf) | STATCOM Grid-support functions Volt/VAR | Hz/Watt | Volt/Watt | Fixed PF Islanded control modes V&f Control power options 208 - 240 VAC | DC: 24 VDC