Loading...
HomeMy WebLinkAboutRevised Site Plans rev 3-16-22LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]1 - PROPOSED CONTOUR [98.41 PROPOSED SPOT EL. TH1 TEST HOLE 25, SLOPE OF GROUND rQ> UTILITY POLE FIRE HYDRANT NOTE: NOI ALL SYMBOLS MAY APPEAR N DRAWNG THE YARMOUTH BOARD OF HEALTH SHALL REQUIRE THE FOLLOWING INSPECTIONS: 1. INSPECTION OF UNSUITABLE MATERIAL (IF ANY). SYSTEM PROFILE (NOT TO SCALE) MARK CORNERS OF 2. VERIFICATION OF SOIL CONDITIONS AND/OR GROUNDWATER ELEVATION (IF NECESSARY) PROVIDE MIN. 20" DIAM. WATERTIGHT PROVIDE MIN. 20" DIAM. WATERTIGHT LEACHING FIELD W/ PROVIDE INSPECTION PORTS TO 3. VERIFICATION OF CESSPOOL/LEACH PIT REMOVAL OR ABANDONMENT (IF NECESSARY) ACCESS COVERS TO GRADE ACCESS COVERS TO GRADE REBAR SET 4' BELOW WITHIN 3" OF FINISH GRADE 4. 5. INSPECTION OF CONTAINMENT WALL OR FLOW BARRIER INSTALLATION (IF ANY) INSPECTION OF THE 3/4 - 1 1/2 INCH STONE PRIOR TO PLACEMENT \ TOP FOUND. EL. 12.2' GRADE 2% SLOPE 6. FINAL INSPECTION OF ALL COMPONENTS PRIOR TO BACKFILLING 9.5 j Q•Q' MINIMUM FILTER FABRIC .75' OF COVER OVER PRECAST MINIMUM .75' OF COVER OVER PRECAST TOP 8.68' 7. FINAL GRADING INSPECTION 9-5 FINISHED GRADE- 4" LOAM &SEED OR PAVE AS RED. 8. INSPECTION OF THE START-UP OF INNOVATIVE/ALTERNATIVE TECHNOLOGY (IF ANY) PRECAST H-10 PRECAST H-10 WITH VENDOR REPRESENTATIVE RISERS (IYP.) RISERS (TYP.) 4"OSCH40 PVC 2'0 6' MIN- SUMP PIPES LEVEL 1ST 2' CLEAN FILL RIVERFRONT MITIGATION CALCULATIONS: HARDSCAPE 0-100' 100-200' EXISTING: 3490 SF 3305 SF PROPOSED: 2569 SF 7784 SF CHANGE: -921 SF 4479 SF REQUIRED MITIGATION : >2:1 3558*2 = 7116 SF (9,850 SFt PROVIDED) (1.38 X MIN. AMOUNT) J. m a 0 0 U Da q 0 DCE ¢#21-158 PUMP CHAMBER STAKED LT F / 2.5Y 7 6 2.5Y 7 6 � WORK LI 1. DATUM IS NAVD 88 / / MAP 34 P RCEL 1 % 2. MUNICIPAL WATER IS EXISTING (NOT TO SCALE) ROBERT MCC LLO JG WATERPROOF/WATERTIGHT \ �` CERT 24�5 �- 219.50 •,E ���• y ,� /i a „1 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 7 BENCHMARK: +N80 16 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO 96" -3' 96" -3' WACEMENT BOUND GE- --'\ 6 - _ (fi] �y ,) ID X-�'"X t v yTo BE AASHO H-29 GRPLE =5.0' NAVD88 X_�Xl /yam 5. PIPE JOINTS TO BE MADE WATERTIGHT. G-W ADJ. DATA: GROUNDWATER AT 48" MAP 34 PARCEL 292.1 SWA E-, f, �• 0) X XRETAINING WALL ` "/IJ5�5], „ � � TR• y n � 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH WELL: MIW 29 ELEVATION 1.0' \ JOSEPH GILMORE g'44"E _ X--� (6.2] qR V 310 CMR 15.000 (TITLE 5.) ZONE: A \ N78 2 X yc SMART /R- CERT 225924 g2 N ' ( y �y� ADJ: 1.5' ( \ \ 0 185• VENT / y �KJN a y �y 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO DECEMBER 2021 1 \ \ -4-' - - N I 1 1 FLOOD BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. A [3.51 [4] �� [6] o? =�� VENT DEMO 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 6.5 I1 \ [4.5] f y ` y y QS Z 0 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED MAP 4 P RCEL 294 �° 3: , \ 0 I � I % ��~ 17, I l j' y y Z by WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION .4- ) /g -� ' - o O, OBTAINED FROM BOARD OF HEALTH. DUS Al UIER TRS M U' cr 'r -� \.\ 1 i' y / m DB 1386 G 136 � ( ���� i �'41 �� 10 CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING SLAB EL. 6.7' ::� ZAB0. AI00 H-2O 12 MIN. INT. DIM. 4' PFAFORATED PVC S' O.C. S=0.005 -� ° *7 7' t0• FILTER PRIOR TO P/C ip• 2000 GAL ° ° 3/4"-1-1/2" DOUBLE WASHED7.25' TEE H-20 7.00' TEE PUMP CHAMBER 10" STONE LEACHING FIELD 6"DEPTH MIN BELOW INV. TEST HOLE LOGS 2000 GAL LOW PROFILE IE SEE DETAIL BELOW o0000000000o WATERTEST D'BOX -ono"o.,o,o_ FOR LEVELNESS B-33' LEVEL BOTTOM ° 8 O' SEPTIC TANK 4' UQ. LEVEL (ACME OR EQUAL).? 8.62' 8.45' 54.0' ENGINEER: CRAIG J. FERRARI, SE #13871 "o VU 0 0 0 0" o o; o 0 0 0 0 0,, 00 D o 4 OHO"ODO^000"Oo0 O U"0,4^U^000^C G C G a "_ o"o a s��o�8�. s a �000000""a0000000a0000<< UQ .�pppQp"pOp"p"p,y,,,,,,o,,, "" g .0;0..., . c,,,,,p,"O"O"OO, a"q,o,o,o""o" ooa " o 0 0 0,o,o,a,o. 0. WITNESS: CAROL EASTMAN *THE INSTALLER SHALL VERIFY THE �S;o�os"a q,o,o,og"go,o"o ,a,o,o,o �6" 11 29 21 / / LOCATIONS OF ALL UTILITIES AND ALL 6" CRUSHED STONE OR MECHANICAL CRUSHED STONE OR MECHANICAL DATE: BUILDING SEWER OUTLETS AND COMPACTION. (15.221 [2]) COMPACTION. (15.221 [21) PERC. RATE _ < 2 MIN/INCH ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM (2-5% SLOPE) ( z % SLOPE) (_L__ % SLOPE) CLASS I SOILS FOUNDATION- 15' - SEPTIC TANK 2' PUMP CHAMBER 90' D' BOX 12' - ELEV. ELEV. SYSTEM DESIGN: PROP. WATERTIGHT COVER TO GRADE 0" 5' 0" 6' ALARM AND CONTROL PANEL A A TO BE INSTALLED INSIDE PROVIDE QUICK DISCONNECT FOR PUMP GARBAGE DISPOSER IS NOT ALLOWED BUILDING. ALARM TO BE ON #181 EXISITNG 6 BEDROOMS LS LS SEPARATE CIRCUIT FROM PUMP #183 EXISTING 3 BEDROOMS 1OYR 4/1 1OYR 4/1 14" 181• DESIGN FLOW: 9 BEDROOMS ®110 GPD = 990 GPD i_ o, o USE A 990 GPD DESIGN FLOW LS LS INV. IN 6.96' NO LOW POINTS SEPTIC TANK: 990 GPD (2) = 1980 1 OYR 4/6 1 OYR 4/6 2000 GAL. H-20 S/ 2" PRESSURE LINE 30" 2 5' 30" 3.5' 1245 GAL. SLOPE TO DRAIN BACK TO PC USE A 2000 GAL. SEPTIC TANK ALARM ON RESERVE AND A 2000 GAL. PUMP CHAMBER FLOAT SWITCH 0.25" WEEP HOLES SETTINGS: PUMP ON CHECK VALVE LEACHING: C C 4" WORKING RANGE 8 MYERS SRM 4 990 GPD / (.74) = 1338 SF REQUIRED , PERC 4" SUBMERSIBLE 4/10 HP PUMP 25' X 54' = 1350 SF OK PUMP OFF 12" SYSTEM OR EQUAL 1350 SF X .74 = 999 GPD OK MS MS 000 0000000 0 000000 DODO 000o USE A 25' X 54' PIPE AND STON LEACHING IELD \ 7.5' 5.0' -- LOCUS MAP SCALE 1 "=2000't ADJUSTED GROUNDWATER 2.5' ASSESSORS MAP 34 PARCEL 292.2 LEACHING BUOYANCY CALCS: LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 11) FACILITY H-20 2000 GAL. PC WEIGHS 26,000 LBS & VE (EL 13) AS SHOWN ON COMMUNITY PANEL 1.64' x 6 x 11 x 62.4 = 6,755 LBS UP (OK) #25001CO589J DATED 7/16/2014 H-20 2000 GAL. ST WEIGHS 26,000 LBS PROPOSED DWELLING IS WITHIN AE (EL 11) 1.33' x 6 x 11 x 62.4 = 5,478 LBS UP (OK) DESIGN FLOOD ELEVATION 12.0 ZONING SUMMARY / ZONING DISTRICT: RS-40 RESIDENTIAL DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 40,000 S.F. 85,850 S.F. 85.850 S.F. APPROX. ABUTTING MIN. LOT FRONTAGE 150' 149.94' 149.94' /j HOUSE LOCATION ; MIN. FRONT SETBACK 30' 289' 318' MIN. SIDE SETBACK 20' 14.6' 23.6' 0 / MIN. REAR SETBACK 20' - - MAX. BUILDING COVERAGE 25% 6.0% 6.9% MAX. BUILDING HEIGHT 35' NOTES DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO \ �\ [10.2] \ Q 1 COMMENCEMENT OF WORK. / l) O 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE O QQ► REMOVED BENEATH AND 5' AROUND THE PROPOSED % ,% LEACHING FACILITY. /�-- 04 ' c i S �f �_ \ O C / LAJQ J 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND -_-�J ,/ ��5 REM AL OF-WNSUITABLE" SOIL REQUIRED REMOVED OR PUMPED AND FILLED NTH CLEAN SAND. __AROU PERIMETER OF LEACHING FACILITY, y I^ \ 1 -> 0" S PROPOSED / % ti v �y �O DOWN TO SUITABLE SOIL LAYER. REPLACE L i / a l y v 13. POOL FENCE SHALL HAVE SELF -CLOSING WITH CLEAN MED. SAND, TO MEET I O \ I _ S DWELLING2 2 ((( SELF -LATCHING S MATERIALS TO MEET :IFICATI NS OF 310 CMR 15.255(3) -- \ �°Aj1� ,y kQ y �" SELF LA D STATE GATE ,SIZE AND Q �( 000"S / \ � / � y � � Q � � LOCAL AND STATE BUILDING CODE, ALL DWELLING DOORS SLAB = 6.7 %O A OPENING TO POOL SHALL BE ALARMED TO CODE. OF AS IN AREA SHOWN.(cl n I ! y 14. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. y J r [8] ` `" 4 y a O ��0 WATER RESISTANT CONSTRUCTION UP TO ELEVATION 12.0. PROVIDE OV108.T9800TTOMOATIEN3R,tT 5 !\ \ s��i DEMO ¢ �'✓ �I PROPOSED/ y i v -, •� TOP AlAT POOL 15. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO \ \ [6] O, w /m 65,4, = y DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. 1 U / AR / w � rti \ �1, � �' " %/ ��> � � ,� rj ��' 0 16. ACCESS FOR ROUTINE MAINTENANCE MUST BE J / F\ \� 1 1 "RESET -�W - O TJ /i s y,' PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW / -' L ' Q, I MANUFACTURER'S SEPCIFICATIONS FOR PROPER FILTER PROPOSED /" i � y Vy y O=y INSTALLATION. 5.7] �\ W PATIO 2 41 h ., / \ �, �y v 17. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS VI ' `1 f O�G �/ i / / 4 y O� �'1` SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT V LOT 3 E E E -7 Q i 1 e [10 2 1, Q 2 I, REQUIRED. �� 85,850 S.F.f I- - - - _ t _ GARAGE �,�( ; o , ,� `\ 1 /iW \ -- ��' � SLAB = 11.7 \- �p�11; •/ 4� �a y }, 1 ��5 r] o 1 [5.51 [5] % j A A T .� -GRASS' E f° h 0 LE s�'y e y8, 7 P21�OSED O� [8] �L� .. / � Z6191 EX G4R5] S DRAINAG� % J a^ D' I�E i �� D,EMQ ,4 91 q� .,� Y, _ y 1 NDING #150 SOUTH STREET AS i % U STA�;� b SILT FENCE " , / WALE l I / 7 L - Lam: K LIMIT LINE 78 A. o TH2- _ III ° .� �, y iSOUTH YARMOUTH MA J Cj� �� 6 _ _ _ 10- OU R RIPARIAN ZONE---"?CD C6 �� �� 7 9100 S.F. TOTAL MITIGA PLATNING AREA PROP D WALL 82'41'40"E ' TOW = 10.5 ° -�� 42$_�3 MAP 34 CEL 295 TAPERS TO d ROBE T HILDS O GRADE l- 3-16- DATE DANIEL A. OJALA, P.E., P.L.S. SITE PLAN PREPARED FOR JOSEPH GILMORE DATE: JANUARY 13, 2022 REV. MARCH 2, 2022 REV. MARCH 16, 2022 (INCREASE BUFFER) Scale: 1 "= 20' ! /L 0 10 20 30 40 50 FEET off 508-362-4541 fax 508-362-9880 I downcape.com 0 down cope engieeefing, 4C. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 LICE #21-158 LEGEND LAioiirvo wrviUUM X 89.1 EXIST. SPOT ELEV. —[991— PROPOSED CONTOUR 198•41 PROPOSED SPOT EL. TH1 0 TEST HOLE 7%� SLOPE OF GROUND CVj UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRM MIG \�S E �7 /v GENERAL PLANTING NOTES 1) ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN STANDARD FOR NURSERY STOCK BY THE AMERICAN NURSERY & LANDSCAPE ASSOCIATION OR THE PLANT MATERIAL WILL BE UNACCEPTABLE. ALL PLANT MATERIAL SHALL BE TRUE TO SPECIES, VARIETY, SIZE AND BE CERTIFIED DISEASE AND INSECT FREE. THE OWNER AND/OR THE LANDSCAPE ARCHITECT RESERVES THE RIGHT TO APPROVE ALL PLANT MATERIAL ON SITE PRIOR TO INSTALLATION. 2) PROVIDE PLANTING PITS AS INDICATED ON PLANTING DETAILS. BACKFILL PLANTING PITS WITH ONE PART EACH OF TOPSOIL, PEAT MOSS AND PARENT MATERIAL. IF WET SOIL CONDITIONS EXIST THEN PLANTING PITS SHALL BE EXCAVATED AN ADDITIONAL 12" AND FILLED WITH SAND. 3) NEWLY INSTALLED PLANT MATERIAL SHALL BE WATERED AT THE TIME OF INSTALLATION. REGULAR WATERING SHALL BE PROVIDED TO ENSURE THE ESTABLISHMENT, GROWTH AND SURVIVAL OF ALL PLANTS. 4) ALL PLANT MATERIAL SHALL BE GUARANTEED BY THE CONTRACTOR FOR ONE YEAR AFTER THE DATE OF FINAL ACCEPTANCE. ANY PLANT MATERIAL THAT DIES WITHIN THAT TIME PERIOD SHALL BE REMOVED, INCLUDING THE STUMP, AND REPLACED BY A TREE OF SIMILAR SIZE AND SPECIES AT THE EXPENSE OF THE CONTRACTOR. 5) ALL PLANTING BEDS SHALL RECEIVE 2" OF SHREDDED PINE BARK. 6) ALL LAWN AND LANDSCAPE AREAS TO RECEIVE 6" MIN. THICKNESS QUALITY LOAM PRIOR TO PLANTING. DCE ##21-158 O PLAN NOTES 1. DATUM IS NAVD88 2. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO , V �' C Qdr BE USED FOR LOT LINE STAKING OR ANY OTHER �., � PURPOSE. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES �g0'p6"E PRIOR TO COMMENCEMENT OF WORK. .16 4. CONTRACTOR TO FOLLOW ORDER OF CONDITIONS, TOWN \ j STORMWATER PERMIT CONDITIONS, AND FILE ENOI FOR CONSTRUCTION GENERAL PERMIT WITH EPA 30 DAYS PRIOR TO GROUND DISTURBANCE. PROPOSED `�✓ ��'" i ' I ' v� MA/N FOR OE ACCESS FOR W9L A&ADO R I MEADOW [6.2] LAWN PROPOSED BA RY�� .F 5. ,1 ,✓ � / IA Q WlN7ERSERRY IN — — RETENTION AREA / / / PROPOSED NEW SEED AMND IX WTLOFLOWER �Cl O _ ,(n �. oo [10.2] PROPOSED CR£ PING JUNIPER TO CONFU WITH 0 OB✓ECT5 BE/NG, FOR WAT[l7 DE DEN / ; s PROPOSED DWELLING Q TOF = 12.2 �� w C� SLAB = 6.7 n N \\ I I 1 1 1- ff Ffwo PROPOSED POOL PROPOSED M"l 7ENANCE ACCESS FOR WILDFLOWER MEADOW LAWN I I � II I CD I PROPOSED 8' BEACH GRASS PROPOSED NEW ENGLAND 7DFL SEED M/X PROPOSED 8' AMERICAN BEACH GRASS BUFFER LOCUS MAP SCALE 1"=2000't ASSESSORS MAP 34 PARCEL 292.2 NOTES: 1. NO SOIL OR MULCH SHALL BE PLACED AGAINST ROOT COLLAR OF PLANT. 2. PLANTING DEPTH SHALL BE THE SAME OR HIGHER AS GROWN IN NURSERY. TOP OF ROOTBALL SHALL BEAR SAME RELATIONSHIP TO FINISHED GRADE AS TO PREVIOUS EXISTING GRADE � RESTORATION PLANTING SCHEDULE SYMBOL PLANT NAME SIZE QUAINT. AMERICAN BEACH GRASS 018" O.C. ULLg 1,800 AMMOPHILA BREVLIGULATA -600 SF 00 EE NEW ENGLAND COASTAL #1 PER 2 75 LBS SALT TOLERANT SEED MIX -5,000 SF 1,900 SF SWEET FERN #1 18 COMPTONIA PER£GRINA BUSH CINQUEFOIL #2 21 POFEN77LLA FRU177COSA CREEPING JUNIPER #2 28 ✓UNIPERUS HORIZONTALIS WINTERBERRY 16 ILEX VERNCILLATA #3 �} NORTHERN BAYBERRY MYRICA PENSYL VANICA #3 22 NEW ENGLAND WILDFLOWER PLACE BALL ON SUBSOIL. REMOVE AND DISCARD BURLAP EXCEPT UNDER BALL. REMOVE ALL SYNTHETIC SOIL WRAPPING MATERIALS (TREATED BURLAP, NYLON TWINE, WIRE BASKETS, ETC.) AND DISCARD EXCAVATE SUBSOIL AS REQUIRED TO PLACE ROOTBALL TO PROPER ELEVATION. PLACE ROOTBALL DIRECTLY ON SUBSOIL EXCAVATE HOLE TO DIAMETER 3X WIDER THAN ROOTBALL. BACKFILL HOLE WITH PLANTING SOIL MIX AS SPECIFIED 3" BARK MULCH, AS SPECIFIED UNDISTURBED SUBGRADE SHRUB PLANTING NOT TO SCALE SEED MIX: SITE PLAN LITTLE BLUESTEM, RED FESCUE, INDIAN GRASS, PARTRIDGE PEA, CANADA WILD RYE, VIRGINIA WILD OF RYE, BLUE VERVAIN, BUTTERFLY MILKWEED, LE BLUE EYED GRASS. BLACK EYED NARROW # 5 0 S O U T I� STREET SUSAN, NEWW ENGLAND ASTER, SPIKED GAYFEATHER/ MARSH BLAZING STAR, STARVED/CALICO ASTER, EARLY GOLDENROD, HOLLOW -STEM JOED PYE WEED R O U T® e�y, i Y A R M O U T H, M 1,900 SF /POUND THE NEW ENGLAND WILDFLOWER MIX PROVIDES A PREPARED FOR SELECTION OF NATIVE WILDFLOWERS AND GRASSES TO INSURE THAT A VARIETY OF SPECIES HALL p SURVIVE IN CONDITIONS FROM DRY TO MOIST. JOSEP p�y� B ,{�� ''E. ILMORE DATE: MARCH 2, 2022 REV.: MARCH 16, 2022 (INCREASE BUFFER) Scale:l "=10' 0 5 10 15 20 25 FEET 16 2z Off 5OB-362-4541 fax 508-362_9880 downaape.Com down cape engineering, i�c, civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675