Loading...
HomeMy WebLinkAboutPlanQUANTITY BOTANICAL NAME COMMON ION NAME SIZE ROOT SPACING 20 VACCINIUM ANGUSTIFOLIUII LOWBUSH BLUEBERRY 2' x 2' 1 GAL. POT 3' O.C. 30 ARGT05APHYLO5 UVA-UR51 BEARBERRY I' x 4" 4" POT 2' D.C. LOCUS INFORMATION CURRENT OWNER: BARRY GAUGHRAN OVERLAY DISTRICT: NONE HELEN GAUGHRAN NITROGEN SENSITIVE TITLE REFERENCE: DEED BOOK 30352, PAGE 318 ZONE: NOT A ZONE II FEMA FLOOD PLAN REFERENCE: PLAN BOOK 65, PAGE 89 ZONE DISTRICT: AE EL.=11 DATED 7/15/14 ASSESSORS MAP: 43 PANEL #25001CO589J PARCEL: 1 MINIMUM LOT SIZE: 40,000 S.F. ZONING DISTRICT: RS-40 EXISTING LOT SIZE: 29,275f S.F. SETBACKS: FRONT 30' EXISTING LOT COVERAGE: 4,447/29,275=15.2% SIDE 20' REAR 20' PROPOSED LOT COVERAGE: 5,302/29,275=18.1 % N/F STEPHEN A. MOSCA 109B RIVER STREET ASSESSORS MAP 42 PARCEL 123 \ \ j \ \ \ N/F P%q \ ® DANIEL P. GORMAN \ \ — 10 ®\ \ 109A RIVER STREET ASSESSORS MAP 43 \ \ \ PARCEL 3 h® N/F \ � �• � Nss• S� 43, ROBERT E. PERETTI \ \ owl 2020- 18 WILLOW LANE ASSESSORS MAP 42 N/F r — N/F PARCEL 124 JONATHON D. LAWRENCE ,�`�% & DAVID E. McCARTY TR, 117 RIVER STREET GARAGE v �` �109 RIVER STREET ASSESSORS MAP 42 �� `� ASSESSORS MAP 43 Vo c z N ST LOCUS N BASS RIVER STAGE ISLAND pR NANTUCKET SOUND S SNpR LOCUS MAP NOT TO SCALE LEGEND N/F NOW OR FORMERLY 11.1 X SPOT ELEVATION C.B. o CATCH BASIN DMFI0 DRAINAGE MANHOLE LP •4- LIGHT POLE UP � UTILITY POLE 0 W — OVERHEAD ELECTRIC LINE o EI-H ELECTRIC HANDHOLE —E— UNDERGROUND ELECTRIC ® GMET GAS METER —G— GAS LINE —S— SEWER LINE — W— WATER LINE WG ® WATER GATE PARCEL 149 ,� EXISTING ^� PARCEL 2 NOTES: / \ Q DWELLING � / a #115A � 1. THE ELEVATIONS DEPICTED ON THIS PLAN ARE / #115A � �0� ON NAVC 88 DATUM. � SHE _ � p�'�P � SHED BARN/ CIO 2. THE PUR OSE OF THIS PLAN IS TO PERMIT RAISING THE EXISTING MAIN DWELLING, AND GARAGE SHE® Nss202o� JF`�0 ADDITIONS, TO BE ABOVE THE CURRENT FLOOD A/ �' o '`o l ZONE. / i sX ��- \ / 3. THE PROPOSED MAIN DWELLING IS TO BE SHED CONSTRUCTED WITH THE NEW TOP OF W PROPOSED S S / o ,o, �� FOUNDATION AT ELEVATION 12.1' MIN. (NAND 88) o / 0 750f S.F. OF �P EXISTING / / / / / ® ry �, , `Y MITIGATION S�P�' x DWELLING �CIV pP 04 #117 / GRgIt s\. X1o.3' 2017 s ��goo N ® / ORS / S. �!_ APPROXIMATE C X '`/i i?'J'✓ra y FF�� SEPTIC .0• L CATIONX9.7' XI 0 X10.1' EXISTING X1 .1 PROPOSED / j' 4'. /, `,; J. \ �0 \ X9.T / 1 DWELLING ENTRANCE �. Pc, J O 00 \ \ �p N/F PROPOSED o / WG s \ / BARRY GAUGHRAN `� /ADD17ION FF 111.5 ® @HW C 2� ol< \ \ `��• 115 & 115A STREET �``� OHW `� o �' S2S• "0" % TO BE RAISED s- ASSESSORS MAP 43 �� %`'�, �/� TOP OF PROPOSED OHW / / �,� 0`� l PARCEL 1 I ``J \�� FOUNDATION = 12.1 ® O10 36" CD O / GR X9.8 I 1 EXISTING `f' e / TREE �� PARCEL"/ j \ ®(/ \ \ X9.9 GRASS o / �� 3,883± S.F. S/j q G PARKING W \ .qy�® \ \ AREA \ F\ \ X9.6' REBUILT \ w \ PORCH' l \ \\\ \ \ M X10. PORCH X10. - r cOs2'E \ 4p 7' D � GAUC? \ \\ \ N N/F � \ � \ \ \ , „co* FREDERICK W. JORDAN & LORNA J. ROMANO oy/ \ c oD 121 RIVER STREET \ \ ^� ASSESSORS MAP 42 ��. ' \ \ \ \ G X10.3' 7 .9 `,�) `n PARCEL 148 N HYD T / TABOLT 12.1 2. 8 N D C-2 /UOQ k E �0 2� m0 I O BUFFER DISTURBANCE m �q• co RIVERFRONT AREA 19.361t S.F. 0-100' 0 S.F. m / 100'-200' 742f S.F. IV I (750f S.F. OF MITIGATION) 11 COASTAL BANK / ok / 0-35' 0 S.F. `L 35-50' 0 S.F. 50'-100 217f S.F. LAND SUBJECT TO COASTAL STORM FLOWAGE 1,384f S.F. I,Q:o a, If Ono NOTE: 0 EXISTING SEPTIC SYSTEMS AND UTILITIES WHERE SHOWN ON THIS DRAWING ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY LOCATING AND COORDINATING ANY PROPOSED CONSTRUCTION ACTIVITY WITH DIG — SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG —SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-800-322-4844. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS & VISIBLE FIELD MARKINGS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. I CERTIFY TO THE BEST OF MY PROFESSIONAL KNOWLEDGE, INFORMATION AND BELIEF THAT THE LOT CORNERS, DIMENSIONS AND SETBACKS TO THE STRUCTURE AS DETERMINED BY INSTRUMENT SURVEY AND AS SHOWN ON THIS PLAN ARE CORRECT. �jH fw KIERLW J. HEALY y NO.481 Q KIERAN HEALY DATE FOR THE BSC GROUP INC. PLAN OF LAND 115 RIVER STREET AND 115A RIVER STREET IN SOUTH YAR M 0 UTH MAS SAC H U S ETTS (BARNSTABLE COUNTY) PROPOSED CONDITIONS MARCH 14, 2022 REVISIONS: NO. DATE DESC. PREPARED FOR: BARRY GAUGHRAN 1440 V.F.W. PARKWAY BOSTON, MA 02132 349 Main Street, Rt. 28, Unit D W. Yarmouth Massachusetts 02673 508 778 8919 © 2022 The BSC Group, Inc. SCALE: 1 " = 20' 0 2.5 5 10 METERS iiiiiii 0 10 20 40 FEET PROJ. MGR.: C. FIELD FIELD: S. CROWLEY CALC./DESIGN: K. HEALY DRAWN: P. HAGIST CHECK: K. HEALY FILE: 9274—EXC.DWG DWG. NO: 5841-03 SHEET 1 OF 1 JOB. NO: 4-9274.03