Loading...
HomeMy WebLinkAboutEngineer PlansLOCUS MAP Yarmouth Health Department APPROVED S7 ZLVAIL- c /� 3 2 2 Name Date Note: EXISTING SAS IS IN APPROXIMATE LOCATION OF PROPOSED SAS. EXISTING SAS TO BE REMOVED TO FACILITATE INSTALLATION OF NEW SAS �AI N111nRIA8LE RIGHT OF T EXISTING 4072 SF COMMERCIAL BLDG. W/2 BR APARTMENT #161 >8' EXISTING 10009 STaI.nk TO BE REMOVED s Boo IS' 1. Contractor is responsible for Digsafe notification, Verification of Utilities and protection of all. underground utilities and pipes. + /TEST' HOLE Ir f ELEV.- 89.000 NEW REMOVE & REPLACE -5' ALL AROUND ( + Note: Remove soil down to el. 88.00 & lace with replace clean coarse sand w/pero. rate less p than or + / 9�� %' O Se= Tghk / stones over 3" in size. or equal to 2 min./In. before & after placement + I 0 2 Cam"I"T' t I TANK + i i 111 TEST HOLE #1 .'• • ." ' it ,P / �� ELEV.m 99.00 ENGINEER INSPECTIONS: ( ,�' i l i with Title V of the Massachusetts state code, the approved 1: STRIPOUT BOTTOM OF HOLE INSPECTION ew PI • .: 4 2: FINAL INSPECTION 6. If, during installation the contractor encounters any _04 � + e.75' installation must halt & immediate notification be made to Shay Environmental Services 7. No vehicle or heavy machinery shall drive over the f LOT #CIO i septic system unless noted as H-20 septic components. 40,771 99uaere Peat 8. Install Tuf—Tite gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF cb 10. All solid piping, tees & fittings shall be 4" diameter 0 20 40 50 SCALE: 1 "=30' 11. Municipal Water is AVAILABLE. ALL PROPERTIES WITHIN 150 EXISTING 10009 STaI.nk TO BE REMOVED NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FROM THE EXISTING SAS ABANDONED AND TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. REV. MARCH 4, 2022 — PER YARMOUTH COMMENTS 2-1-2022 PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR 161 MAIN STREET CONDOMINIUMS AT ac��oe� 161 MAIN STREET PARCEL ID: 122-123—C10 NAR 21 2022 YARMOUTHPORT MA HEALTH DEPT. PREPARED BY: CARMEN E. SffA Y r ", "ENVIRONMENTAL SERVICES P.O. Box 1576 MASHPEE, MA 02649 TELEFAX : 508-294-7498 SCALE: 1 "=30' DRAWN BY: CES DATE: DEC 22, 2021 PROJECT#161 MAIN FILENAME: 161 MAIN.DWG I SHEET 1 OF 3 GENERAL NOTES 1. Contractor is responsible for Digsafe notification, Verification of Utilities and protection of all. underground utilities and pipes. 2. The septic tank anq distribution box shall be set level on 6" of 3/4 —1 1/2" stone. 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Shay Environmental Services 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and Local Regulations. _ 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in our design installation must halt & immediate notification be made to Shay Environmental Services 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install Tuf—Tite gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is AVAILABLE. ALL PROPERTIES WITHIN 150 FEET ARE CONNECTED TO MUNICIPAL WATER. THE PROPERTY LINES ARE APPROXIMATE AND COMPILED FROM THE SURVEY PLAN AT THE BARNSTABLE REGISTRY OF DE PLAN BOOK 457 PAGE 37 BY DOWN CAPE ENGINEERING DATED: 5/11/1988 IECT BENCH MARK OF FOUNDATION AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN . = 100.00 (ASSUMED) IT SHOULD BE USED FOR NO PURPOSE OTHER THAN THE SEPTIC SYSTEM INSTALLATION. NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FROM THE EXISTING SAS ABANDONED AND TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. REV. MARCH 4, 2022 — PER YARMOUTH COMMENTS 2-1-2022 PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR 161 MAIN STREET CONDOMINIUMS AT ac��oe� 161 MAIN STREET PARCEL ID: 122-123—C10 NAR 21 2022 YARMOUTHPORT MA HEALTH DEPT. PREPARED BY: CARMEN E. SffA Y r ", "ENVIRONMENTAL SERVICES P.O. Box 1576 MASHPEE, MA 02649 TELEFAX : 508-294-7498 SCALE: 1 "=30' DRAWN BY: CES DATE: DEC 22, 2021 PROJECT#161 MAIN FILENAME: 161 MAIN.DWG I SHEET 1 OF 3 10' min. EXISTING Foundation house to Sf *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. -Grade over 11No Tank - 99.00 COVERS TO GRADE MTN STEEL RINGS D -80X cover must & COVERS ALL INLETS/OUTLETS 7TO GRADE WITH STEE VENT PIPE (® Least Schedule 40 PVC w, SAS RING/COVER TO GRADE cover WITH tSTEEL. RING/COVER SECTION A -A rade aver D -Box - 99.CO ---odea over SAS - 99.00 PROFILE VIEW OF LEACHING SYSTEM 3-24" DIAM. ACCESS MANHOLES 6' STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3-24' REMO IABIE COVERS OUTLET H2O TANK THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SET DEEPER THAN 6 INCHES BELOW FINISHED GRADE SHALL BE RAISED TO GRADE WITH STEEL RINGS AND COVERS INSTALL TUF-TITS GAS BAFFLES OR EQUALS �wt1:n r' B -2" min. depth I 12•-2" 1 1 8.1-8. .. ; .•,:7 _ CROSS SECTION NOT TO SCALE END -SECTION TYPICAL 2500 GALLON SEPTIC TANK/2 COMPARTMENT Design Calculations Numbeoc RETAILFSPACEa2000of sSF 050 uGol/1000 SF ivolent to 0 100 al/Day OFFICE SPACE -2000 SF 075 Gal/1000 SF = 150 Gal/Day Note: Remove soil down to el. 88.00 or C-1 Layer & replace with clean coarse sand y,/perc. rate less than or or equal to 2 min. In. before & after placement PERCOLATION TEST Date of Percolation Test: AUGUST 27, 2021 Test Performed By. CARMEN E. SHAY, R.S., C.S.E. tesults Witnessed By: BRUCE MURPHY - YARMOUTH BOH EXCAVATOR: SHAY ENVIRONMENTAL SERVICES Percolation Rate: Less Than 2 MPI 0 132" -Sieve Test Hole S=0.01 5 HOLE 0 99.00 I I Asphalt 198.50. Greater (H-20) DIST. BOX 98.50 TOP OF SAS - 96.50 32 6"-12" 98.00 Sandy Loam EXIST. PIPE 00 0 500 GALS. tV o 20' 0.010" Par foot 97.00 — Be FRO14 FOUNDATION r SEPTIC TAN In SILT LOAM FAm OWN,m 25 Y 8/4 m COMPAR NT 6 23 88.00 o Med.-Coors Gas Bo as Sand o 0 0 2.5 Y 7/4 CONCRETE FULL FOUNDATION)i II H-20 m y 132"-180 ai ai m m u A 41g SYSTEM PROFILE 6 in.of 3/4' Iy > ; 14 S' P oampocted atone Not to Scale S y 5 d o 3 v !3'- m TRIPOUT Effective Width OVIDE �� -II c c _= -J N REMOVE & REPLACE TO 6 im1/2' BOTTOM OF C-1 LAYER NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN AT GRADE ted st compspacted atone a WITH STEEL RIMS AND COVERS Bottom of Test Hole 1 Elev.= 84.00 3-24" DIAM. ACCESS MANHOLES 6' STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3-24' REMO IABIE COVERS OUTLET H2O TANK THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SET DEEPER THAN 6 INCHES BELOW FINISHED GRADE SHALL BE RAISED TO GRADE WITH STEEL RINGS AND COVERS INSTALL TUF-TITS GAS BAFFLES OR EQUALS �wt1:n r' B -2" min. depth I 12•-2" 1 1 8.1-8. .. ; .•,:7 _ CROSS SECTION NOT TO SCALE END -SECTION TYPICAL 2500 GALLON SEPTIC TANK/2 COMPARTMENT Design Calculations Numbeoc RETAILFSPACEa2000of sSF 050 uGol/1000 SF ivolent to 0 100 al/Day OFFICE SPACE -2000 SF 075 Gal/1000 SF = 150 Gal/Day Note: Remove soil down to el. 88.00 or C-1 Layer & replace with clean coarse sand y,/perc. rate less than or or equal to 2 min. In. before & after placement PERCOLATION TEST Date of Percolation Test: AUGUST 27, 2021 Test Performed By. CARMEN E. SHAY, R.S., C.S.E. tesults Witnessed By: BRUCE MURPHY - YARMOUTH BOH EXCAVATOR: SHAY ENVIRONMENTAL SERVICES Percolation Rate: Less Than 2 MPI 0 132" -Sieve Test Hole No. 1 DEPTH SOILS ELEV. 0 99.00 Asphalt 198.50. 0"- 6" 98.50 DENSE GRAD 6"-12" 98.00 Sandy Loam 12"-24" 10 VR 5/6 97.00 12"-24" Be SILT LOAM 54"-96" 25 Y 8/4 91.00 24"-132"Ci Sand 88.00 Med.-Coors Sand 96"-150" 2.5 Y 7/4 86.50 132"-180 <SR myel C 84.00 Leaching Capacity Proposed: 470 Gal./Day Minimum (Min. Per Title V) Septic Tank : - 2 x470 Gal./Day = 940 GPD USE NEW 2500 GAL. 2 Compartment Septic Tank -H20 24 Hr Retention = 940 Gallons -1500 Gallon Min. Compartment 24 HR Retention =470 GPD -1000 Gallon Min Compartment SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch Bottom Area: 0.74 gal/day/sq. ft. x 546 sq. ft. = 404.04 gallons/day Sidewall Area: 0.74 gal,/day/sq. ft. x 220 sq. ft. = 162.80 gallon/day Providing: = 566.84 gallons/day Use: (4) 500 H-20 CONCRETE CHAMBERS, HAVING A 2' EFFECTIVE DEPTH, (5' W x 8.5' L) TO BE USED WITH 4' OF WASHED STONE ON THE SIDES AND 4' OF WASHED STONE ON THE ENDS. Test Hole No. 2 DEPTH SOILS ELEV. 0 99.00 Asphalt a"- 6" 98.50 ENSE GRAD 6"-12" 98.00 0M5/6 12"-24" B, 97.00 SILT LOAM 25 Y 8/4 54"-96" C. 91.00 Sand 2.5 Y 7/4 c5% Gravel 96"-150" Ce 86.50 Perc #1 Depth to Perc: 132" -Sieve Analysis Perc Rate= <2 MPI Groundwater Not Observed No Observed ESHWT ADJUSTED H2O Elev. = None m I I/4 • x%asea peNe4 Stew INSPECTION cover must be\ TO GRADE W/STEEL RINGS & COVERS 0 0 00 0 0 0 4 Units @ 8.5' = 34' 41 r/a" - r/a' rwwe Aaemne Effective Length SOIL ABSORPTION SYSTEM (SAS) 500 - C H-20 LEACHING UNITS / WIGGINS PRECAST Not to Scale 1r --I CONCRETE COVER 3 - S' OUTLET KNOCKOUTS 4" - $CH. 40 Teems 200' PLAN SECTION CROSS—SECTION 5 HOLE H-20 DISTRIBUTION BOX NOT TO SCALE REV. MARCH 4, 2022 — PER YARMOUTH COMMENTS 2-1-2022 PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR 161 MAIN STREET CONDOMINIUMS T 161 MAIN STREET ASSESSORS ID: 122 -123 -CIO "R 2 2 72 . YARMOUTHPORT. MA %RED BY: RHEN E. ASWA Y T/ P.O. BOX 1576 MASHPEE, MA 02649 aa�ss TEL/FAX : 508-294-7498 SCALE: N/A SHEET 2 1 DRAWN BY: CES DATE: DEC 22, 2021 ROJECT#161 MAIN STREETFILENAME: 161 MAIN STREET.dwgl SHEET 2 OF 3 No : w "ual b 2 mK/in. baton R ENGINEER INSPECnONS: 1: STMPOUT BOTTOM OF NOL: MSP:CDO 2: FK4L INSPECTION (01 a. �-4IN ,5"T'REET WAY) ttmTrla mtt � cao.lmara Ntt. •R ex Murtrwwr /1a1 9 800 IS- 28. g / l J /8 / / / 6 / �/;MT Nal£ n ---7 u / aLv.. aam o ) % r-D, TNAf e / / O sAs mrt P6TNMVM $ J 3 / / / / / / A641 L_GIGI _4! (01 a. �-4IN ,5"T'REET WAY) ttmTrla mtt � cao.lmara Ntt. •R ex Murtrwwr /1a1 9 800 IS- 28. g l J E 11 I j' —-J �/;MT Nal£ n ---7 I aLv.. aam o ) % r-D, TNAf Onsr / O / G1C11 BA41 / I 1 / / 1 / J rr��l L0Y jC/O % 11 Rim 2 3 V4OM2 nN _ easM+a ro eE Marom BENCH MARK FOUNDAMON - 100.00 (ASSUMED) (REV. MARCH 4, 2022 — PER YARMOUTH COMMENTS 2-1-2022 1 PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR 161 MAIN STREET CONDOMINIUMS AT 161 MAIN STREET ASSESSORS ID: 122-123-C10 YARMOUTHPORT. MA PREPARED BY: CARMEN E. SHAY ENVIRONMENTAL SERVICES P.O. BOX 1576 MASHPEE, MA 02649 TEL/FAX : 508-294-7498 SCALE: 1 "-40' DRAWN BY: CES DATE: DEC 22, 2021 'ROJECT#161 MAIN STREETFILENAME: 161 MAIN STREET.dwgl SHEET 3 OF 3 i J E 11 J ggh / I / / Onsr / O / G1C11 BA41 / I 1 / / 1 / J i _ easM+a ro eE Marom BENCH MARK FOUNDAMON - 100.00 (ASSUMED) (REV. MARCH 4, 2022 — PER YARMOUTH COMMENTS 2-1-2022 1 PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR 161 MAIN STREET CONDOMINIUMS AT 161 MAIN STREET ASSESSORS ID: 122-123-C10 YARMOUTHPORT. MA PREPARED BY: CARMEN E. SHAY ENVIRONMENTAL SERVICES P.O. BOX 1576 MASHPEE, MA 02649 TEL/FAX : 508-294-7498 SCALE: 1 "-40' DRAWN BY: CES DATE: DEC 22, 2021 'ROJECT#161 MAIN STREETFILENAME: 161 MAIN STREET.dwgl SHEET 3 OF 3