Loading...
HomeMy WebLinkAboutReview Cheklist /4.-i'-(g3 TOWN OF YARMOUTH / SEWAGE PLAN REVIEW CHECKLIST _ Location: A.M. / 7 Lot '6 Zone of Contribution: In Out c _ reage Commercial: Residential: �.__...--- Street: 7( � ��� ��� Village: (/ Floor Plan: #Bedrooms: j I C Owner: 77~ C )5/ ' /// Installer: A c Address: /� Phone: r-C/L ar/2- Phone: 774--- 2 79-- D711J Builder: f. 617 Address: Phone: S`7I 77 9. 6/.- Phone: Phone: Atr--( ,4 �4 L L -t L.I.'zL N/A NO 1.Required# of copies received _ 2.Date of soils exam and percolation test not older than 2 years (/-- 3. 4-5 ft of naturally occurring pervious material, above water table _ -- _ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ' �---- - r 5. Water line 10 ft from septic components Var.: ..__.-� 6.Benchmark indicated and shown-NGVD if near wetlands c 7. Septic tank minimum 10 ft from foundation, deck Var.: t�- 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: - 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 1 � _, .____ 12. System meets all other setback requirements Var.: L-----' 13.Uses adjustment for maximum high groundwater Var.: t...„-- 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: L 15. System not in top or subsoil(A,B horizons) or 5' removal 16.Proposed contours are suitable L-------- 17. System meets slope requirements-min. 1/8", 1/4"preferredL__....----- 18. -r 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee . _ - 20. Sewage is under 10,000 gpd for parcel k.----4- 21.No garbage disposal ,,_,,/s- 22. System adequately sized for its intended use 'L.-- 23.Minimum 6"stone or compacted below tank and dbox `..----- 24.Manhole covers within 6"of grade, pump chamber cover to grade . ------ 25. 25.Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes �- - 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size ...,------- 28. ..,--%28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet, under driveway/parking 30.Buoyancy calculations for tank/pump chamber k.-------- 31.Engineer to inspect and certify soils: wall: commercial: ,.....32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature .._.___----- 33. ��33.H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature ..._------- 35.Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd `� 37. Check area lots for groundwater/Label groundwater in Assessor's Map -.----- Plan reviewed by: 'G' 6/03/03