Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Ell Lot lb3 Zone of Contribution: In Out x Acreage i44-112.9.0 -A-2- Commercial: Residential: x Street: SOO Zoo T.E (JA Village: (-1, 1z4vt _yr -t' PO lei' Floor Plan: ki. #Bedrooms: S Owner: St-t&(LA-- tvi fi1-'LG- Se4e X17 Installer: Address: Phone: Phone: Builder: Engineer: t.3t C�20t..)-9 Address: Phone: CS-010 R-a - S191.01 Phone: N/A YES NO 1.Required#of copies received V 2.Date of soils exam and percolation test not older than 2 years V 3.4-5 ft of naturally occurring pervious material,above water table I 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: / / 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation,deck Var.: ,✓ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: /, 9.Leaching minimum 100 ft from wetlands Var.: �V/ 10 .Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: J 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: >/ 13.Uses adjustment for maximum high groundwater Var.: ,, 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable / 17. System meets slope requirements-nun. 1/8", %"preferred / 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee ,/, 20. Sewage is under 10,000 gpd for parcel `I 21.No garbage disposal ✓ 22. System adequately sized for its intended use ,� 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade ✓/ 25. Inspection port on plastic chambers/leach field J 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 1.// 28. Septic tank/pump ✓chamber to be factory waterproofed ` 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: / / 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater �/ 34.Title V Application and permit fee,installer signature / �/� 35.Foundation footing min.2 feet above adjusted ground water for new house ✓/ 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 1 ►'i ri G..� (A..� t vvi vvt .' '2 6 03 03