Loading...
HomeMy WebLinkAboutPermit & Compliance No.: BOHDC-14-0449 Commonwealth of Massachusetts Fee $55.00 Board of Health, Yarmouth, MA. APPLICATION FOR DISPOSAL SYSTEM CONSTRUCTION PERMIT Application for a Permit to: Upgrade- Location: 981 ROUTE 28, SOUTH YARMOUTH, MA 02664 Owner Map/Parcel#: 042.43 Name: CMSIX PROPERTIES LLC Address: C/0 MOY FONG 63 LAWTON STREET Phone: Septic System Installer Name: CAPEWIDE ENTERPRISES, LLC Address: 153 COMMERCIAL STREET MASHPEE, MA 02649 Phone: Type of Building:Other Type of Building Lot Size:0.61 sq.ft. Dwelling-No.of Bedrooms: Garbage Grinder: Other Type of Building:RESTAURANT No.of persons: 112 Showers: Cafeteria: 92 SEATS,20 BAR STOOLS Other Fixtures: Plan Date:06/18/2014 Number of Sheets: 1 Title:SITE AND SEWAGE PLAN REPAIR SYSTEM I FOR 981 ROUTE 28 Revision Date:06/29/2014 Design Flow(min.required):3620 gpd Calculated design flow: 1761 Design flow provided: 1761 gpd gpd Description of Soils:SEE PLAN Soil Evaluator Form No.: Name of Soil Evaluator: Date of Evaluation:05/16/2014 EDWARD STONE.PLS • DESCRIPTION OF REPAIRS OR ALTERATIONS:SYSTEM#1 2000 GAL GREASE TRAP 5040 GAL SEPTIC TANK DBOX 70'X 34'X 6"LEACH FIELD=1761 GPD The undersigned agrees to install the above described Individual Sewage Disposal System in accordance with the provisions of TITLE 5 and further agrees not to place in operation until a Certificate of Compliance has been issued by the Board of Health. Signed Date Inspections Commonwealth of Massachusetts Board of Health, Yarmouth, MA. Fee DISPOSAL SYSTEM CONSTRUCTION PERMIT $55.00 Permission is herby granted to;RICHARD CAPEN Address: 153 COMMERCIAL STREET MASHPEE,MA 02649 To perform: Upgrade an individual sewage disposal system. Owner: CMSIX PROPERTIES LLC C/0 MOY FONG 63 LAWTON STREET BROOKLINE,MA 02446 Location:981 ROUTE 28,SOUTH YARMOUTH,MA 02664 Disposal System Construction Permit No.: BOHDC-14-0449,Dated: October 10,2014 Provided: Construction shall be completed within six months of the date of this permit. All local conditions must be met. Conditions 1. Repair of System #1: Total Kitchen Flow=1761 gpd(92 Seats +20 Bar Stools x 15 gpd= 112 Seats) 2000 gal Grease Trap, 5040 gal Septic Tank, DBox, 70'x 34'x 6"Leach Field 2. System #2: Total Flow =2300 gpd(92 Seats +20 Bar Stools x 35 gpd= 112 Seats) Existing 3500 gal Septic Tank, Replace DBox, Existing 100'x 23'x 6"Leach Field Total Flow Provided: 1761 gpd(Kitchen Flow) +2300 gpd(Restaurant Flow) =4061 gpd 3. Engineer to Inspect and Certify Installation 4. MFC Variance: 1. Setbacks 2. Groundwater 3. Depth /4041/ Bruce G. M hy, MPH, R.S., CHO/Amy L.von Hone, R.S.,CHO Health Director/Assistant Health Director • The issuance of this permit shall not be construed as a guarantee that the system will function as designed.