Loading...
HomeMy WebLinkAboutBLDE-22-004091 ti NEW PHOTOVOLTAIC SYSTEM 10.00 KW DC >I 60 SPARROW WAY, YARMOUTH, MASSACHUSETTS, 02664, USA C GENERAL NOTES Digitally signed byXiaojian VICINITY MAP C` Yi a tan Yioxie ae: v► =\ 1.1.1 PROJECT NOTES: osoo cvs 4 (1) 1.1.2 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE NATIONAL PROJECT INFORMATION ELECTRIC CODE(NEC)ARTICLE 690,ALL MANUFACTURER LISTING AND XA"ty Stcre by Ccmcast INSTALLATION INSTRUCTIONS,AND THE RELEVANT CODES AS SPECIFIED BY THE OWNER Wendy 49 © 9 cncol v AUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. NAME:PATRICK SHANAHAN x " '" 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV PHONE:(508)776-7866 Dose Rd .60 Sparrow Way, +:, Q Q i_ SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. a South Yarmouth MA z = �j = Q 1.1.4 ARC FAULT PROTECTION(AFC')AND PHOTOVOLTAIC RAPID SHUTDOWN = w SYSTEM(PVRSS)IS INTEGRATED WITH THE POWER OPTIMIZER IN ACCORDANCE y " $ Z H ()7 U) CONTRACTOR INFORMATION: wrr ,- a = 0 WITH NEC 210.12&690.12 RESPECTIVELY. a CONTRACTOR NAME:PALMETTO w O = 1.1.5 GROUND FAULT DETECTION AND INTERRUPTION(GFDI)DEVICE IS *,,, (n Q CONTRACTOR ADDRESS:1505 KING ST, 1` >,. INTEGRATED WITH THE INVERTER IN ACCORDANCE WITH NEC 690.41(B) $ �' CHARLESTON,SC 29405 co 1.1.6 ALL PV SYSTEM COMPONENTS;MODULES,UTILITY-INTERACTIVE U Q v U INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND CONTRACTOR PHONE:(855)339-1831 .t„ !, ws,, a 2 0- } 2 O LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4:PV SATELLITE VIEW a a MODULES:UL1703,IEC61730,AND IEC61215,AND NFPA 70 CLASS C FIRE INVERTERS:UL 1741 CERTIFIED,IEEE 1547,929,519 COMBINER BOX(ES):UL 1703 SCOPE OF WORK OR UL 1741 ACCESSORY SYSTEM SIZE: STC:25 X 400W=10.00 kW DC -' 1.1.7 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP PTC:25 x 376.55W=9.41 kW DC COEFFICIENT FOR VOC.IF UNAVAILABLE,MAX DC VOLTAGE CALCULATED AC SIZE:7.6 kW AC • ACCORDING TO NEC 690.7. (25)QCELL()PEAK DUO BLK ML-G10 400W N 1.1.8 ALL INVERTERS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AND (1)SOLAREDGE SE7600H-US RGM SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER (25)SOLAREDGE POWER OPTIMIZER P401 • w SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR ATTACHMENT TYPE:ROOF MOUNT rss LABELING[NEC 110.3]. MSP UPGRADE:NO t5 1.1.9 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. S IF EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. AUTHORITIES HAVING JURISDICTION BUILDING :YARMOUTH 1.2.1 SCOPE OF WORK: ZONING :YARMOUTH SHEET INDEX 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND UTILITY :EVERSOURCE(MA) SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT.PRIME T•001 COVER PAGE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE DESIGN SPECIFICATION 1 REQUIREMENTS TO DESIGN,SPECIFY,AND INSTALL THE EXTERIOR A-101 SITE LAN OCCUPANCY :R3/SINGLE FAMILY RESIDENTIAL ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS A-102 ELECTRICAL PLAN 5 DOCUMENT CONSTRUCTION TYPE/FIRE RATING:5-B A-103 ATTACHMENT PLAN re SNOW LOAD STATE :50 PSF A-104 MOUNTING DETAILS 1.3.1 WORK INCLUDES: SNOW LOAD LOCAL :30 PSF E-601 LINE DIAGRAM 1.3.2 PV RACKING SYSTEM INSTALLATION-QUICK MOUNT PV WIND EXPOSURE :B E-802 ELECTRICAL CALCULATIONS 1.3.3 PV MODULE AND INVERTER INSTALLATION-Qcell QPEAK WIND SPEED STATE :120 MPH E-603 PLACARD DUO BLK ML-G10 400W/SOLAREDGE SE7600H-US RGM/ WIND SPEED LOCAL :140 MPH R-001 RESOURCE DOCUMENT SOLAREDGE POWER OPTIMIZER P401 WIND SPEED NOTE :PER 780 CMR 9TH EDITION R-002 RESOURCE DOCUMENT R-003 RESOURCE DOCUMENT 1.3.4 PV EQUIPMENT ROOF MOUNT ACTUAL LISTED SPEED IS 140 MPH R-004 RESOURCE DOCUMENT SHEET TITLE 1.3.5 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX R-005 RESOURCE DOCUMENT COVER PAGE 1.3.6 PV LOAD CENTERS(IF INCLUDED) 1.3.7 PV METERING/MONITORING(IF INCLUDED) APPLICABLE CODES&STANDARDS 1.3.8 PV DISCONNECTS BUILDING :IBC 2015 DRAWN DATE 01/14/2022 1.3.9 PV GROUNDING ELECTRODE&BONDING TO(E)GEC RESIDENTIAL :IRC 2015 DRAWN BY AS 1.3.10 PV FINAL COMMISSIONING ELECTRICAL :NEC 2020 REVIEWED BY - 1.3.11(E)ELECTRICAL EQUIPMENT RETROFIT FOR PV FIRE(LOCAL&STATE) :IFC 2020 SHEET NUMBER 1.3.12 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING OTHER :MASSACHUSETTS STATE BUILDING CODE T-001 CODE (9TH EDITION) (---- ....A---)e ___. 22_, 00409 C 2.1.1 SITE NOTES: 2.4.1 WIRING&CONDUIT NOTES: 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION C 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH NOTES: C OSHA 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH OSHA THE REGULATIONS.V MODULESARE CONSIDERED NON-COMBUSTIBLE AND THIS THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS AREBASED ON THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS2. =, SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITHOUT STORAGE MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS BATTERIES.M UP-SIZING. MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS). CO B THE INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY SOLAR PV INSTALLATION ROOF VENTS. 2.4.4 VOLTAGE DROP LIMITED TO 3.0%. PERSONNEL,BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH MECHANICAL,L,ACCESS BUILDING ING WORKING CLEARANCE AROUND EXISTING 2.4.5 DC WIRING LIMITED TO INVERTER FOOTPRINT.OPTIMIZER WRING 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS 2.1.5SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE Z >- (n AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SUITABLE WIRING CLIPS. SHOCK HAZARD FOR EMERGENCY RESPONDERS IN = Q SECTION NEC 110.26. 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS:PHASE A ACCORDANCE WITH 690.12(A)THROUGH(D). �w 2.1.6 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND R Z = W Q OR L1-BLACK PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING � Q � ? CO MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER INSTRUCTIONS SUCH THAT THE ROOF COVERING PHASE PHASE C OR L3-BLUE,YELLOW,ORANGE**,OR OTHER TO NEC 690.8,890.9,AND 240. '' = O O D SERVES TO PROTECT THE BUILDING OR STRUCTURE. CONVENTION NEUTRAL-WHITE OR GREY IN 4-WIRE DELTA CONNECTED 2.6.6 OPTIMIZER BRANCHES CONNECTED TO A SINGLE w SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC Y 52.2.1 EQUIPMENT LOCATIONS: [NEC 110.15]. 110.3(B). w (� Q Q co co O 2.6.7 IF REQUIRED BY AHJ,SYSTEM WILL INCLUDE ARC-FAULT 3 E - p 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY 2.5.1 GROUNDING NOTES: CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND I- O7 Q NEC 110.26. UL1699B. 0- CEO 2 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 PURPOSE,AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS (A),(C)AND NEC TABLES 310.15(B)(2)(A)AND 310.15(B)(3)(C). SHALL BE RATED FOR SUCH USE. 2.7.1 INTERCONNECTION NOTES: 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 MODULES ACCORDING TO NEC 690.34. AND MINIMUM NEC TABLE 250.122. 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN 2.2.5 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE 2.5.4 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ACCORDANCE WITH[NEC 705.12(A)] INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER te 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED 250.138(A). CONTINUOUS OUTPUT MAY NOT EXCEED 120%OF BUSBAR PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED RATING[NEC 705.12(B)(3)(2)]. 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED ACCORDING TO NEC 690.45 AND INVERTER MANUFACTURER 2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) FOR OUTDOOR USAGE WHEN APPROPRIATE. INSTRUCTIONS. 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS OUTPUT CIRCUIT CURRENT AND THE RATING OF THE 2.3.1 STRUCTURAL NOTES: AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL THE AHJ. IF WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE 2.3.2 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED ACCORDING TO BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE BUSBAR,PV DEDICATED BACKFEED BREAKERS MUST BE CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS REQUIRE A LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUSTALSO MANUFACTURER INSTALLATION REQUIREMENTS. SOURCE OCPD[NEC 705.12(B)(3)(1)]. EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE 2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED 2 7 5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT ARRAY/SUBARRAY,ACCORDING TO RAI MANUFACTURER'S SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A COMBINER PANEL,TOTAL RATING OF ALL OVERCURRENT �¢ INSTRUCTIONS. GROUNDING CONDUCTOR TO ANOTHER MODULE. N DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' 2.5.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE NEC 705.12(B)(3)(3). SPECIFICATIONS.IF ROOF-PENETRATING TYPE,IT SHALL BE FLASHED& COLORED GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 2.7.8 FEEDER TAP INTERCONECTION(LOADSIDE)ACCORDING SEALED PER LOCAL REQUIREMENTS. 250.119] TO NEC 705.12(B)(2) 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILLBE COMPLETED 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 2 7 7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A AND NEC 250.50 THROUGH 250.106.IF EXISTING SYSTEM IS NEC 705.11(A)WITH SERVICE ENTRANCE CONDUCTORS IN LICENSED CONTRACTOR. INACCESSIBLE,OR INADEQUATE,A GROUNDING ELECTRODE SYSTEM ACCORDANCE WITH NEC 230.30 OR 230.43 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER PROVIDED ACCORDING TO NEC 250,NEC 690.47 AND AHJ. 2.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING SHEET TITLE 2.3.6 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE AND(2)TO REDUCE FIRE HAZARDS [NEC 705.12(E)]. NOTES STAGGERED AMONGST THE ROOF FRAMING MEMBERS. DRAWN DATE 01/142022 DRAWN BY AS REVIEWED BY SHEET NUMBER G-001 COORDINATES: CO/ (41.683641, -70.207417) 136'-11" C C C % �` - j % 1 cn j /' z } up a 4z : j N L, Q =� Q 5a315w � w = oo = 2 YXM0S (N)SOLAREDGE SE7600H-US RGM INVERTER / a I— (n (n (N)PV PRODUCTION METER / ato 2 (N)VISIBLE LOCKABLE LABELED AND FUSIBLE AC . • / DISCONNECT(UTILITY DISCONNECT) AIMARRAY AREA&ROOF AREA CALC'S c, (E)UTILITY METER == / ROOF F. ARRAY ROOF AREA N -- --- __ I � / /-M T I ' ROOF MO#DOULF ES AREA AREA COVERED w ; (SQ.FT.) (SQ.FT.) BY ARRAY 2 /3''4"/ (%) CD 13'-0" #1 7 147.9 835.03 23.270 w 1 #2 12 253.8 379.79 88.763211 #3 6 120.8 37525 33.785478 E / TOTAL 25 528.3 2587.32 20.416879 b (E)MAIN SERVICE PANEL / 1 MODULE QCELL()PEAK DUO BLK ML-G10 400W (INSIDE GARAGE) I CV 2 INVERTER SOLAREDGE SE7800H-US RGM G I CTI 3 OPTIMIZER SOLAREDGE POWER OPTIMIZER P401 I—_ L() 4 MOUNTS QMLM-B-12,L-MOUNT ATTACHMENT 5 RAIL IRON RIDGE XR-10-188M,XR10 RAIL y IN 1 L_________________—_-_____, _ LEGEND 63' 2" 33,2" ����A -FIRE SETBACK ------- -PROPERTY LINE SHEET TITLE N - - - -FENCE SITE PLAN IJBI -JUNCTION BOX DRAWN DATE 01/142022 SKYLIGHT(ROOF OBSTRUCTION) DRAWN BY AS W— ` — E 1 SITE PLAN SPARROW WAY ® REVIEWED BY - ( ® -CHIMNEY(ROOF OBSTRUCTION) SCALE:1/25" = 11-0" SHEET NUMBER S O 0 VENT,ATTIC FAN(ROOF OBSTRUCTION) A-101 • ����L�EGEND O -MODULE STRING ROOF SECTION(S) �/ A -FIRE SETBACK © MODULE STRING ROOF 1 AZIMUTH-MODULE-7 182° C 1 -PROPERTY LINE C TILT-23°-o-- ° -FENCE ROOF 2 AZIMUTH-92° C IJBI -JUNCTION BOX MODULE-12 =, ® -SKYLIGHT(ROOF OBSTRUCTION) TILT-26° CO ROOF 3 AZIMUTH-272° I ® -CHIMNEY(ROOF OBSTRUCTION) MODULE-6 I O ❑ -VENT,ATTIC FAN(ROOF OBSTRUCTION) Z > c — 2z5F� a Yce U (fl 3 FeQQfA0 Le I— 9. a co < ROOF 2 (N)SOLAREDGE SE7600H-US RGM INVERTER O O 0 O O rc (N)PV PRODUCTION METER O O O 0 a 8 (N)VISIBLE LOCKABLE LABELED AND FUSIBLE AC O O _________\ N DISCONNECT(UTILITY DISCONNECT) O S (E)UTILITY METER El 0 O O Oi, . .. 0 ROOF 3 8 0 0 El ®2 A ZN O 5 K B ROOF 1 (E)MAIN SERVICE PANEL (N)CONDUIT RUN (INSIDE GARAGE) IN THE ATTIC SHEET TITLE N ELECTRICAL PLAN 1 MODULE WELL()PEAK DUO BLK ML-G10 400W DRAWN DATE 01/14/2022 W 0E 1 I ELECTRICAL PLAN 2 INVERTER SOLAREDGESE7800H-US RGM DRAWN BY AS REVIEWED BY 3 OPTIMIZER SOLAREDGE POWER OPTIMIZER P401 SCALE:3/32" = 11-0" 4 MOUNTS OMLM-B-12,L-MOUNT ATTACHMENT SHEET NUMBER S 5 RAIL IRON RIDGE XR-10-188M,XR10 RAIL A-102 ROOF SECTION(S) MOUNTING PATTERN SAMPLE `��V/ ROOF MATERIAL- 2'-1" 2-7 /_ ROOF COMPOSITE SHINGLE / 10' 4" 13' 9" 13' 10" &_NkNa \\`� C C ROOF MATERIAL- �\`'r��\`�-N C ROOF 2 COMPOSITE SHINGLE <`? I _` MAXIMUM MOUNT SPACING: MOUNT PATTERN STAGGERED 1 0' - • • • • ALL HARDWARE,INCLUDING MOUNTING `-0---•7FI AND RACKING,TO BE INSTALLED PER ROOF MATERIAL- _ MANUFACTURER SPECIFICATIONS. ROOF 3 COMPOSITE SHINGLE N Q Q Uj • • •- • -• •• 2 Q5 =r --•--•-—CLAMPLI MODULE MOUNT DEG— -RAIL182 DEG a c7 jr. o -RAFTER d co M -, 4'-0" r- -A 4'-0" A- y "? -, 4'-0" 0' • • • • • - Ili t --- i ° - • • — • • c0 •• • — •— • —• • • v _• • - a • - • • -- • - • - • 0 EN - • - • • • • -• - • • E S - • S. • • -,k 4'-3"-1 20'-9" / ,1,- '1". 17'-6" / 10'-4" / 1'-2" 1'-1" SHEET TITLE ROOF 2 ARRAY 3 ATTACHMENT PLAN TILT-23 DEG TILT-26 DEG AZIMUTH-92 DEG AZIMUTH-272 DEG DRAWN DATE 01/14/2022 DRAWN BY AS REVIEWED BY 1 I ATTACHMENT PLAN SHEET NUMBER SCALE:3/16" = 1'-0" A-103 —a. 0 73 0 C �Nx o O IT, w C) Z ma m z -I mm• 5 0 ,;0 3 Z a a C) o 0 Or 0 UI +0C- ,,s,diiii. \It, 4.°-' \''..111 ..''-‘ lJJ Zi 3 v C m z D r= \ ilt10 \ \ A ? 3 A Z a Fri a 71 o 0 itm PJ 8 00 0 cn C o C -i 1 y m m > F 2 -i Z A - _ M A m 8 Z T 0 D A REVISIONS SIGNATURE WITH SEAL PROJECT NAME 8 ADDRESS D m Z REV DESCRIPTION DATE PATRICK SHANAHAN o ; m m Z 60 SPARROW WAY, A m 0 YARMOUTH, S U n n nVa m v m MASSACHUSETTS, p . y o m 02664, USA • PHASE CONDUCTOR QTY,SIZE GROUND CONDUCTOR QTY,SIZE CONDUIT AND TYPE PER CONDUIT NEUTRAL AND TYPE PER CONDUIT SIZE CONDUIT TYPE DC SYSTEM SIZE:10.00 kW DC _ AC SYSTEM SIZE:7.6 kW AC 1 4 AWG#10 PV-WIRE/USE-2, N/A 1 AWG#6 BARE,COPPER EGC N/A FREE AIR C COPPER 2 4 AWG#10 THWN-2,COPPER N/A 1 AWG#10 THWN-2,COPPER EGC 3/4" EMT (' 3 2 AWG#8 THWN-2,COPPER 1 AWG#8 THWN-2,COPPER 1 AWG#8 THWN-2,COPPEREGC 3/4" EMT 4 2 AWG#6 THWN-2,COPPER 1 AWG#6 THWN-2,COPPER 1 AWG#8 THWN-2,COPPER EGC 3/4" EMT 5 1 AWG#6 BARE,COPPER N/A FREE AIR ��_, LO 2 Q I— rc Q = tr., Sco co B m co (25)OCELL QPEAK DUO BLK ML-G10 400W MODULES 0 V Q X Q (p (1)STRING OF 13 MODULES CONNECTED IN SERIES (1)STRING OF 12 MODULES CONNECTED IN SERIES 3 a u) N Q _-- - SOLAREDGE SE7B00H-US ROM(240V) F/ 7890VI (EMI-DIRECTIONAL �l 0 C OUTPUT:240 VAC,32A UTILITY METER a co C 9996 CEO WEIGHTED EFFICIENCY 1-PHASE,3-W, NEMA 3R,UL LISTED.INTERNAL GFDI 20V 21 OCELL QPEAK DUO BLK WITH INTEGRATED DC DISCONNECT METER NO.:23 2378567 ML-010400W CTS ��\/— ——— `J 1 ti M L2 TO UTILITY GRID On' 12 13 L DC AC N iT 1 2 3 e e o 1 40 11WJ AC DISCONNECT: ¢ + PV PRODUCTION METER VISIBLE,LOCKABLE.LABELED F JUNCTION BOX NEMA 3R,UL LISTED BOA FUSED,(2)40A FUSES,240V ` 800 V.NEMA 3 I I LI L1 NEMA 3R,UL LISTED 1 N e le+ �. e e e I UL LISTED ' n I L3 L3 1 12 V -' �11 J C N N N V V7. V — ® C I O L_—FYI �___�—__ -G__7 LINESUPPLY SIDE TAP a 1 2 3 o 0 0 \\\JJJ 11 12 —T— — J -- f� TOP LUGS TO THE I-1 240 V,100A/2PKER//JJUTILITY S BOTTOM LUGSTO SOLAR GENERATION (E)MAIN SERVICE PANEL 0 0 0 - 4 t3+ + 100A RATED.240V _ (INSIDE GARAGE) LINE SIDE CO 5 INTERCONNECTION LpAD I N ATMAINPANEL 8 50 L_�9 rc C PER ART 705.12(D) 10 y SOLAREDGE POWER OPTIMIZER P401 DC input Power-400 watts �11OEC Maximum Input Voltega-SO We 1,;1V EXISTING GROUNDING MPPT Range-Bts L—————JeO Vac _i_ ELECTRODE SYSTEM Maximum Input Current-11.75 Ado a TO EARTH Maximum Output Current-15 Ado Sirkp REF.NEC 250.52, urnne ons-B to 25 Optimizers, 250.53(A) �y 8000 watts SIC per string maximum SHEET TITLE LINE DIAGRAM 1 MODULE °CELL QPEAK DUO BLK ML-G10 400W DRAWN DATE 01/14rz022 2 INVERTER SOLAREDGE SE7800H-US RGM DRAWN BY AS 3 OPTIMIZER SOLAREDGE POWER OPTIMIZER P401 REVIEWED BY - 4 MOUNTS QMLM-B-12,L-MOUNT ATTACHMENT SHEET NUMBER 5 RAIL IRON RIDGE XR-10-168M,XR10 RAIL E-601 SOLAR MODULE SPECIFICATIONS MANUFACTURER/MODEL* QCELL QPEAK DUO BLK ML-G10 400W DC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: >/ VMP 37.59V ARRAY TO JUNCTION BOX: C IMP 10.64A EXPECTED WIRE TEMP(In Celsius) 50° NO.OF INVERTER 1 C VOC 45.06V TEMP.CORRECTION PER TABLE(310.16) 0,82 EXPECTED WIRE TEMP(In Celsius) 28° ISC 11.16A NO.OF CURRENT CARRYING CONDUCTORS 4 TEMP.CORRECTION PER TABLE(310.16) 0.96 C TEMP.COEFF.VOC -0.27%"C CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1 NO.OF CURRENT CARRYING CONDUCTORS 3 PTC RATING 376.55W CIRCUIT CONDUCTOR SIZE 10 AWG CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1 —MODULE DIMENSION 73.79"L x 41.14W x 1.25"D(In Inch) CIRCUIT CONDUCTOR AMPACITY 40A CIRCUIT CONDUCTOR SIZE 8 AWG V J CIRCUIT CONDUCTOR AMPACITY 50A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) INVERTER SPECIFICATIONS 18.75A 1.25 X Ise REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) Z MANUFACTURER/MODEL* SOLAREDGE SE7600H-US RGM 1.25 X MAX INVERTER OUTPUT CURRENT 40.00A Q } (n DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 co = Q NOMINAL AC POWER 7600 W TEMP.CORRECTION PER TABLE(310.16)X 32.80A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 w Q 5 1- Q NOMINAL OUTPUT VOLTAGE 240 VAC CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)X TEMP.CORRECTION PER TABLE(310.16)X 48.00A Q Z NOMINAL OUTPUT CURRENT 32 CIRCUIT CONDUCTOR AMPACITY CONDUIT FILL CORRECTION PER NEC 310.15(B)(2Ha)X Q ? D j j RESULT SHOULD BE GREATER THAN(18.75A)OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR AMPACITY m I O SOLAREDGE POWER OPTIMIZER P401 CIRCUIT CONDUCTOR SIZE AND AMPACITY RESULT SHOULD BE CIRCUIT CONDUCTOR GREATER SIZE THAN AMP(40TY Y !r 0 coA)OTHERWISE LESS THE ENTRY FOR CO w U Q ce < co MAXIMUM INPUT POWER 400W MINIMUM INPUT VOLTAGE 8VDC DC CONDUCTOR AMPACITY CALCULATIONS: ¢3 'a'/^� }. Q o MAXIMUM INPUT VOLTAGE 60 VDC a V/ MAXIMUM MODULE ISC 11.75 VDD FROM JUNCTION BOX TO INVERTER: d coa MAXIMUM OUTPUT CURRENT 15 VDC AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT— 22° PER NEC 310.15(B)(2)(c) NUMBER OF CURRENT EXPECTED WIRE TEMP(In Celsius) 28°,22'•50' PERCENT OF VALUES CARRYING CONDUCTORS IN EMT TEMP.CORRECTION PER TABLE(310.18) 0.82 w 0.80 4-6 NO.OF CURRENT CARRYING CONDUCTORS 4 — 0.70 7-9 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2Xa) 0.6 g 0.50 10-20 CIRCUIT CONDUCTOR SIZE 10 AWG W CIRCUIT CONDUCTOR AMPACITY 40A a 65 AMBIENT TEMPERATURE SPECS a REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) RECORD LOW TEMP -16' 18.75A AMBIENT TEMP(HIGH TEMP 2%) 28' 1.25 X km W DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 6 CONDUIT HEIGHT 0.5" TEMP.CORRECTION PER TABLE(310.16)X 26.24A ROOF TOP TEMP 50' CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)X CONDUCTOR TEMPERATURE RATE 90' CIRCUIT CONDUCTOR AMPACITY MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%I'C RESULT SHOULD BE GREATER THAN(18.75A)OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY B1 y a 4 SHEET TITLE ELECTRICAL CALCULATIONS DRAWN DATE 01/142022 DRAWM BY AS it REVIEWED BY SHEET NUMBER E-602 • CO/ WARNING:PHOTOVOLTAIC PHOTOVOLTAIC AC DISCONNECT C SOLAR PV SYSTEM EQUIPPED POWER SOURCE WITH RAPID SHUTDOWN MAXIMUM AC OPERATING CURRENT: 32 LABEL LOCATION: CONDUIT,COMBINER BOX,JUNCTION BOX MAXIMUM AC OPERATING VOLTAGE: 24o (PER CODE:NEC 690.31(D)(2) TURN RAPID SHUTDOWN . SWITCH TO THE .e o nnuo MAIN PHOTOVOLTAIC LABEL LOCATION: 'OFF'POSITION TO _� � AT AC DISCONNECT:ADD LABEL TO INTERIOR OF AC DISCONNEC AS WELL AS THE EXTERIOR. SHUT DOWN PV SYSTEM (PER CODE NEC 690.54) AND REDUCE � SYSTEM DISCONNECT SHOCK HAZARD Z } (n IN THE ARRAY LABEL LOCATION: Q Q AC DISCONNECT,MSP (PER CODE:NEC 690.13(B) MAXIMUM VOLTAGE: 480V Q I `LABEL LOCATION: J MAXIMUM CIRCUIT CURRENT: 30A S w = O O SERVICE EQUIPMENT-MOP MAX RATED OUTPUT CURRENT OF THE (PER CODE:NEC 880.66(CJ(1)) 3 Y �wreMog PHOTOVOLTAIC CHARGE CONTROLLER OR DC TO DC 15A 0 < Q CONVERTER(IF INSTALLED): a w- >_ co p RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM AC DISCONNECT LABEL LOCATION: PV DISCONNECTING MEANS 0- co M (PER CODE NEC 690.53) LABEL LOCATION: LABEL LOCATION: AC DISCONNECT ON OR NO MORE THAN 3FT FROM RAPID (PER CODE:NEC 890.13(B) SHUTDOWN SWITCH = (PER CODE NEC 690.56(C)(2)) y x CAUTIONIV b LABEL LOCATION: POWER TO THIS BUILDING IS ALSO SUPPLIED SERVICE EQUIPMENT-MOP (PER CODE:NEC 890.58(B) FROM THE FOLLOWING SOURCES WITH 690.4(D),705.10,705.12) DISCONNECTS LOCATED AS SHOWN: a LABEL LOCATION: ADJACENT TO THE BACKFEED BREAKER (PER CODE:NEC 705.12) ELECTRIC SHOCK HAZARD 4 1 N TERMINALS ON BOTH LINE AND Pe i LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION ' (PER CODE NEC 890.13(B),NEC 890.15) LABEL LOCATION: �� SERVICE EQUIPMENT-MSP PV DISCONNECT(FUSED)(PER CODE:NEC 705.12) (E)UTILITY METERuI: SHEET TITLE PLACARDS MAIN SERVICE PANEL DRAWN DATE 01/14/2022 (INSIDE GARAGE) N DRAWN BY AS PV ARRAY REVIEWED BY SHEET NUMBER E-603 m z 'm C)'1 . m „i z \ . < E' O Z C A ; C O r i ,x, ©_ n e V it 'mx s °= , 0 gR m°A mTA `�`3 o ' c'("' ^max 11 o m o m? n° mr 3 w x O mHnZ 3y Sn5 3o o'wa n,$ m'm v- - n m <5 s z E g-'a o f o S m i 23 3 2.5 m o N3. 43.O o� o 1 0 3 a 3 o ae m� t-n� /1110:1 _1 /� O� O 0. �3-"3 7 �! CI 7V 'n s a F. A � pth i:i1 D N m 94 rG � 3 � T 1 1 18 I ▪I-ig I :1 ' 1 'i ei O 1' A_ g t 11.1t 1Vii a 0 m I ! t 0: 'x2 1 � 1 I [ `r s Yo' QI z ; °� �3 4_31 3 3 1 1 1 I 17 I I I> 1 1 m A I A 3. $ T lI '. I I I I i 3� i 3 g ^ D IaI 9 5 "' s I F 3 $ v1 /A m 1_ 14g.F. 3$'l 1 gf S IfI I t! RI I ,n 3�m2 1 j0 1 x 5 g"4 i s 1 $ I ▪N I 1 r 2 g. C :j 3 a : �1 � I� as '$g I 1 -1-1 1-11-�'_I 1�kS1 .� oII -'y 1 1 -tn o3a1' .5E� i 1 1 l iD 3 1- s 112 4 I 1 1 Io O 1 . s'@a , 1 , 1 1 1 1 is O _ 1% ' 1y 1 1 'g 1 11 1oj1 I Ip Iv s 1� < I • 1 �g 11m,1s NI I al n 5 0 1 ! o�ta fI 15.0 I I e e ;1 l 1 If T [y ® I i I� o101 �I s� e '\ o1 Im u "' Ip §tom , - , s e I • `,z 1 1 1 Ia I;sl�l� �1 1 1�1�1i'sl col � E' pg 3�!p 1 I- oos F lot 1 I j ! j g 1 2 I 3 1 1 1 ( i [ 1 1 �Ial 0 1 1 I 9 e -• io, Iti m 1 I I., 3 ( 9 a €i ;n 1'I I Ig� I ' 1 , "Ioi�I 1 1 € D i z e m� P �� (1 ��\) f - I x YD I Z I I $ 1 !�a ! ---- 1 1 1 III 1 y /r/ = i 1 I_; I pj "�� �� S d i F I �M', I ,i e h Noww wn .n w�omuoS e�,o r,,na us a m $ REVISIONSPROJECT NAME 8 ADDRESS SIGNATURE WITH SEAL To * Z Z v X «, DATE PATRICK SHANAHAN o y 13 m m O�m 60 SPARROW WAY, S U n n nv " o Z c 0� �� YARMOUTH, i ~� p mm MASSACHUSETTS, 02664, USA • / Single Phase Inverter >/ With HD-Wave Technology for North America Nom SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ C Single Phase Inverter Z SE7600H-US/SE10000H-US/SE11400H US c C I :.•.Fb.,, ( II II F u0f! , t pl U .F71;p H I d: f 11 I ',I (H l;'I OUTPUT with HD-Wave Technology m Rw 9ACulp. � � 0 n a.�bv ACO for North America M AC R,w GUN, 31p0 160 >40V 'WC' ',n)C 7W' — IR'n II4N '40V VA ✓ 330 m,20RV , C�2�v J y I_0.t,..48V A II VAg M h RMaa lht SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ >11 4 261 z A,1,,fpul Vul'g-Mln F Ma,. _ Vx Q SE7600H-US/SE10000H-US/SE11400H-US „leaf a ,F n , 18.EO, „_ z¢ _ Q 12 25 M a+w so4�u, v5 0 21 _5 4t 47' A Z f ' O • •IIYI .,- M f ua Outs I I6 - N - 48 5 A 2 LI 0 • "A. ,w..... • �remo; oInr.a/°,aae 3 a ¢ N Ol INPUT E i— CO - Q • • h1 C F � 4RP 240V 4650 7750 43:X1 11b]u MOO P650 ',./ Q -- Ma;mtn DCP el@.208V >n0 - 77,1 I - COWW O. co C 11111r- Marim,14 Input.k0tage 4E0 1 ClVc fS... S... Non n,DC rp¢/C4t444e 3B0 400 Vuc _ .. M. I rty. d K1V- 65 105 135 Its .t 27 KJ- Ad, • • •' M IR C0V' _ - 135 , .7 Ad.. Ma,Input I l,en 45 A. • •) Re,4,:e a-aa,tv aloteoon to N • • Grouna Fa, s_la,m Dete:tom 6004,Sens,r,,y KK' ' -- ,, 41 '1 INa,inunl Invetter Efioency ,aa 39: i 2 CE.N 0r IE5 e:cy 9P,C YbW C7 N • •� «., tvglrbr,Po,ver Cmsumplim ,,_ W ADDITIONAL FEATURES .548 ..rcmu .rm ln•Wares RS485 E.1Me-AgOA l4Dn8,. ICAar(nuna,ap a Rtver,ue G,a4e Elam ANSI C1220 4,1,1311 Raptl Sht4(ImYn-NEC 2014 Ana AuIOnVO Rap..1 Shut,.u{nn AC Ulu Dscalnea Optimized installation with HD-Wave technology 2,1/6'i012 I STANDARD COMPLIANCE Safety UC 1741 U11711 SA UI.I699E CSA C222.Canaala,l AFC'a.,o,ding to OIL M-07 / Specifically designed to work with I Extremely small G/)Con 874)04,44„ IEEE 1547.R,11ez1.Rule 14CHIC c. power optimizers En,,,,,, FCC Par,,,CI.,,e N / Record-breaking efficiency I Built-in module-level monitoring INSTALLATION SPECIFICATIONS S Range A,Size/AWG IA-minimuln/CA-6 AWG 3/4'm1nl,r.0 m:N 4AWG Range / Fixed voltage inverter for longertrip / Outdoor indoor installation pc[v.co. An Si,,..S,Cngs, g strings and3/4-mmimlm/I-2 flm /14 FAWG 3'4'mim,evr.,1-)Zn-g,/14-6 AWG AWG Range Dr enstr.,w.Sa'ety 5,ch 146 0874-0s37tCr,4 ' 21 46,'3,'Al I III/ / Integrated arc fault protection and rapid shutdown for I Optional:Revenue grade data,ANSI C12.20 o-I A D- "''^' NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) Woglr w,h Sa0H,Switch 22/n1 I 2s1/114 a2,'II s I 38R/176 Im/Fg Nu, 2, _"0 n0A / UL7741 SA certified,for CPUC Rule 21 grid Cmwog Na,,,Ccn,nCha, compliance 0I. / ns,re Ranw 40 to•14 - a F I 40 C,1m<0I 'F/'C SHEET TITLE Rcatn u_n RAtng NEMA IA,wOe r.15a ,5.,.;1 RESOURCE DOCUMENT solaredge.com • • solar- • • z DRAWN DATE 01/14/2022 ;K a E, row i-: DRAWN BY AS ,,,.,.H::::: .,... ...r....°Z,..,.....,....,.,o.. wa,,.,...,a...-,: M...,a,.,.,,.. _,.,.,,.,.--"----- RoHS REVIEWED BY SHEET NUMBER R-002 • • / Power Optimizer >1 12 For North America C Power Optimizer O P320/P34O/P37O/P4O0/P401/P405/P485/P5O5 C For North America "' ° °` P320/P34O/P370/P400/P401/P405/P485/P505 I• mINPUT R Inpu QC Pe 320 1 340 370 400 405 1 4e- 50S ,''S AL Hre M 1rps antage 48 60 en 60 1 sd[ 25 all +I�eI ,z�// >: v) MPP ppe gR 9 8-48 8 60 8-80 8-tU 12 IDS 125-83 Vdr �l Q VF_AP, hl mSn C .Cuuenl It 101 t IS II H Aac < T WAI?kArJiV O w i- M mLCI W.' nt 13t 101 W65 12i 1H Ad:. Z ±mi— <fil M xn um E'R eill 365 996 '� io �lV:ghlcc E'SnercyassI 6 x O/ p T6; ....;...........1 C T tage Catagct, IItYCOUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTEDTO OPERATING SOLAREDGE INVERTER) UQQ <Ma+lmom CJu:Curren, !iAo< N2c4 5 aam„m 00tp�t v8tage 60 A5 a > o OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Q sa+on,zermo Voltage pet Power c 01 x3r Jp n STANDARD COMPLIANCE EI.IC FCC Part3S Class 8 iiC610i91 6-21EC61000-u-3 N Safety IEC&'1(9-11[las II sOo)I.UL1?41 Material L/L94 V-0 UV limaant ■ • APHS Yes I�I INSTALLATION SPECIFICATIONS 713 Ma.imun AlioNeo System IwoVn[ W dv 2 re C ompati748 inverters All Sr:4TEdge Single Phase ana tires Prat mato, Q, 1t9x 153s 335 1.'.9 x 15i x 29T 129x Ito 5., 2 Dlmenston,NV r L e HI 12ax153,275/5I3tix11 129x 159v dg5/51e63-..19 rr�n [S1xt,13 ;51,6,1.16 SIr64323 Tin <9 Weight luxludng cables, U30/14 750/:1 655/IS 845/i4 1061/23 9r/Ib lop,Corrector MC4' Sltglendual pth MC4" d nptr Wire Length Oitii052 n/Y a Ou,4Ut W m type!Ccvtrector Double lnsulxed/MC4 O.npat Wm Length 0.0/195 I 12/3° Y+,8 PV power optimization at the module-level Co`"wing Tempo ours Rangr' -40-'8'i'40-.185 'F Proterion Rating IRO/NEMA6P Fe1a.ne Humidity 0.100 % o / Specifically designed to work with SolarEdge / Fast installation with a single bolt 4 - -I w n 4,4 1,144P I ,1,44 [Nolorc rh / inverters t1 P Y r J J on-. F b 1 i s n n. >Vo r_�,r, .4 n Vc w.1-++<,,,rvr„-, W / Next generation maintenance with module- ; w w .96 a14 m sv v 1441, �a �r - z / Up to 25%more energy level monitoring =ularmatertre,au,_au8e.e; ,a33P..za:Pa111yn.4a lieler.4,4(rine,WIMILIIPc/,R,1r41,1314 ,rn,741, I Superior efficiency(99.5%) / Meets NEC requirements for arc fault pi, - protection(AFCI)and Photovoltaic Rapid / Mitigates all types of module mismatch losses, Shutdown System(PVRSS) l�r,t,,,r v P320 P340 P370. 8y Song Length 400 P401 6 0 IB from manufacturing tolerance to partial .a,�[a t 1 P�kls.P4es P50; 6 9 w �y shading / Module-level voltage shutdown for installer Ma.1mwn Suing Ler8t111Pcaerc6ur7Nzns/ 25 s so" and firefighter safety F/it,t60in.,n, SHEET TITLE / Flexible system design for maximum space Marlln,mhm,eipeNtrag seem-US-se114w- szb sxv` 12750` , RESOURCE utilization Poi allel Stun9s e'Dineen,¢ngths s ra'ontations Ye: DOCUMENT w..,m,. + 3 x�:m1 trzl^•+ +- DRAWN DATE 01/14/2022 a:.P S x44: P> DRAWN BY AS t4,...,- n„r +rxmw.rtu, L ,ad„ ,444 .H z.+ a - - REVIEWED BY - solaredge.com solar • xp.7 a.... .b+.. mew $0p..x.•..,r->,...,.6 587 SOl+( +,p.. „s6leo .7_....•0, 411.1. SHEET NUMBER RoHS mbemk R-003 ITEM DESCRIPTION CITY. i THIS EDGE TOWARDS ROOF RIDGE 1 FLASHING, ROUNDED CORNERS, 9"X 12"X.040",.438"HOLE.5052, 1 >/ MILL 2 L-FOOT,2"X 3.30"FOR .438"O.D.FASTENER,2-1/16"SLOT, 6061- C T6/6005A-T61,MILL C 3 WASHER,SEALING, 5/16"ID X 3/4"OD. EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD,5/16" x 4", 18-8 SS 1 =t CO STRUCTURAL SCREW,QMPV,T-30 HEX WASHER HEAD, 5/16"X 4-1/2", .5 18-8SS 1 Q Q i1.i)G .5 —�;T ¢ =LQ 0 1I.. o co S El 4.20 1 'STRUCTURAL L' E2 Q- 2 0 3.001 © SCREW < a < i o AVAILABLE ON I QMLM-ST 4.50 II VERSIONS ONLY 0 w IS :1- 2.or -- \ N _ b_ 1 .00 1 .408 , a 1.09 :3.30 i ( .90) [I O AVAILABLE IN MILL, Z AND BLACK FINISHES + . ...... ............ i i Quick Mount PV _T_._____ _.i_.__ _ ; TITLE: 2.50) (3.54) , �� 11 4.04 QMLM & QMLM-ST: L-MOUNT, 2- ,,-,_ -._-__...I.__ 1/16IE SLOT SHEET TITLE C__ . _ I___ RESOURCE '• T UNLESS OTHERWISE SPECIFIED: DOCUMENT QMLM QMLM-S1 OMENSONS AREIN INCHES SIZE DRAWN BY: AAP REV DRAWN DATE 01/14/2022 TOLERANCES: A DATE: ala12o19 11 DRAWN BY AS FRACTIONAL:I/8 REVIEWED BY PSOPRIEAIYANDCONNDENIIAI TWO PLACE DECIMAL !.19 TMEIHPORVATON CO RIMMED IN INS ORAY4NO N THE SOLE PROPERTY OFOW=MOUNT PV.ANY RlPRODECIION INPARTORAS A WHOL EV1TMODTTNE DO NOr SCALE DRAWING MMTENPERMSSIONOIORICE MORNT ND PRONRTEO. COPYRIGHT ID2019 QUICK MOUNT PV THREE PLACE DECIMAL :.094 SCALE:1:4 WBCHT:0.7565 SHEET I OF I SHEET NUMBER 1 5 4 3 2 R-004 I i. r 33 cn 9 9 9 3 ° v-� O o P W g n o.D D D w T X X X m Z A A Z N ` \PN 2 mO cr. NO Q co co or,l J CS::::::1O 7 X X X ID- \ CE O O O n A 11 A m. Q Q Q O P W 7 A OD N v a - 0 8 5 3 3 ° m m m CO 0 ? j a n �m m � o ° o o ° -, 1 » ggrgla \ D P 9 3 25 2'x s< 3 0 ° " a a' Q 9 Q m 3 m' o ° m L. V(l� A 0 0 0 0 OP ° O OO W WNPw /N',0 P t.' >to to V Qt 5' 9' 3' 3 T j Q DJ0 ID REVISIONS SIGNATURE WITH SEAL PROJECT NAME&ADDRESS m 1 v X� DATEPATRICK SHANAHAN 7J T O < D O m2 6 c ,a, m s o 60 SPARROW WAY, S U n r1 nV 0 YARMOUTH, a --I mm MASSACHUSETTS, 02664, USA