Loading...
HomeMy WebLinkAboutBLDE-22-002960 Commonwealth of Official Use Only �E nil Massachusetts Permit No. BLDE-22-002960 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:11/21/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 28 THEATRE COLONY LN Owner or Tenant Natalicia Alves Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (27 Panels 9.585 KW)(28 THEATER COLONY ROAD) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Euuivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 1_� Cominoniuealth o/�a4.v,�{�udell4 Official Only�� 'ff�C i ��CCJiJ�' ►' l et/ �`��� � t �l-i Permit No. a �) —V .BPartmen1 o�Jipe&ruiceo �, - - _ Occupancy and Fee Checked N,;-����44 BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07]• (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(ME ),527 CM 12.00 (PLEASE PRINT IN INK OR TY' ALL INFO N) Date: ( I I (CD D-- ( • City or Town of: \ / rn CX3 \ To the Inspector of Wir s: rf-41 t s application the undersigned =_ ves notice of his or h r intentio I •erform the electrical work described below. T . tdc 'on(Street&Number) !� 0 p . Qw er or Tenant Telephone No. • OW er's Address same as above i'2.- -I .c----kg � 0 4_t is permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box) gut ose of Building dwelling Utility Authorization No. L" . (OCR p ��_r .-rs Ex' ting Service Amps 120 / C�-iWolts Overhea�Dndgrd❑ No.of Meters 1 .-,., NLn evi Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of roof mounted photovoltaic solar systems, --2,-- j- panels 01 . ' & kW Completion of the followin&table may be waived by the Inspector of Wires. Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf Trr ano KVAsformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones of No.of Switches No.of Gas Burners No. In Initiatinnggon Dete and Devices No.of Ranges No.of Air Cond. Total g Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other p Connection No.of DryersHeating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No.H dromassa a Bathtubs No.of Motors Total HP TelecommunicationsNofDevices or Y g No.of Devices Equivalent OTHER: G¢) Attach additional detail if desired,or as required by the Inspector of Wires. �2 Estimated Value of lectri al Work: 1 �n i• (When required by municipal policy.) Work to Start: (p I Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE CO ERA E: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE iii BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete FIRM NAME:Sunrun Installation Services LIC.NO.: Licensee: Nathan Ashe Signatureli'k LIC.NO.:21136A (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:9785943519 Address: 695 Myles Standish Blvd Taunton MA 02780 = r.-:'} ;.. Alt.Tel.No.:8573343116 *Per M.G.L.c. 147,s.57-61,security work requires DeritlYMIterPablInaTety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner 0 owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $ SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:9585W DC,9800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRCI1BC/IEBC), r 'i SOLAR MODULES •MODULES:(27)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE f PV-1.0 COVER SHEET l I LTD:LR4-60HPB-355M INSTRUCTIONS. P —a, PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE3800H-USS3,(1)SOLAREDGE TECHNOLOGIES: MP MAIN PANEL PV-3.0 LAYOUT SE6000H-USS3 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL a — TRACK ON COMP,SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY 0SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT&SKIRT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER 1';_J CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER nr i, ATTIC VENT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. r--�. FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) ® METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. n DC DISCONNECT(S) FIRE SETBACKS •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE -1 INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 (� - (E) EXISTING MI5 rmESSTANISH BLVD.TAUNTO+,w,02r•o-nsi i ESS ENERGY STORAGE SYSTEM PHONE 0 FAX EXT EXTERIOR 0 * ' INT INTERIOR CUSTOMER RESIDENCE: R MAG MAGNETIC NATALICIA ALVES MSP MAIN SERVICE PANEL 28 THEATER COLONY RD, P � '- �I!$' (N) NEW YARMOUTH,MA,02864 Barre y NTS NOT TO SCALE g o OC ON CENTER TEL.(774)271-5424 PRE-FAB PRE-FABRICATED APNITMK#:YARM-000080.000282 5 Theater Colon', PVPSF POUNDS R SQUARE FOOT PROJECT NUMBER: IC 'RC.South Yarmouth.. RSD RAPID SHUTDOWN DEVICE 223R-028ALVE TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL .{°''' V VOLTS STEVE GAILLOT W WATTS 0`�4'''''' REV NAME DATE COMMENTS SHEETCOVER SHEET REV:A 11/10/2021 T° PAGE PV-1.0 t .:► I SITE PLAN-SCALE=1/16"=1' ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SOFT) !* AR-01 23° 241° 255° 392.2 LC INV INV- AR-02 23° 59° 73° 137.3 W --'-......-''-\ SE AC -- / L.0C3 / 4 w .---------------------- \ / , 4 P' .. , (E)SHED (E)RESIDENCE . . 7 .,...., ,,, , 7 .....„, ., (E) DRIVEWAY ,\__ • — (N)ARRAY AR-02 4 7...., • (N)ARRAY AR-01 s u n r u n 4 n O #180120 Z. ON MTLEB STANDISH BLVO,TAUNTON.MA 0I7964331 A PHONED 0 sFAX CUSTOMER RESIDENCE: NATALICIA ALVES / 28 THEATER COLONY RD, YARMOUTH,MA,02664 PL P' TEL(774)271-5424 / APWTMK#:YARM-000060-000262 Pc PROJECT NUMBER: 223R-028ALVE 0- DESIGNER: (415)580.6920 ex3 STEVE GAILLOT SHEET SITE PLAN REV:A 11/10/2021 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF 11'- RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Stay 2X6 RAFTERS 10" 22" COMP,SEE DETAIL SNR-DC-00436 5'-6" 2'-2" 3'-8" 1'-10" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11 22" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-6" 2'-2" 3'-8" 1'-10" STAGGERED 5/16"X4.5":2.5"MIN EMBEDMENT 10" COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:3/16"a 1•-0" ENGINEER OF ANY PITCH:23° POTENTIAL STRUCTURAL AZIM:241° ISSUES OBSERVED PRIOR TO PROCEEDING W/ 2'11• INSTALLATION. • IF ARRAY(EXCLUDING 0 ® ❑ 0 0 0 0 "— SKIRT)IS WITHIN 12" BOUNDARY REGION OF ANY j -I ROOF PLANE EDGES ❑ 0 a Et 0 ❑ 0 0 (EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 5'43"TYP 10'-4" REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS El ❑ ❑ 0 CI 0 ❑ ❑ 0 0 oNL �00orMgs�° FOLLOWS: .•ALLOWABLE ATTACHMENT 'r SPACING INDICATED ON ' VINCENT y�,g g MWUMVANEZA N PLANS TO BE REDUCED BY C)n n C 0n 050% CIVIL ••ALLOWABLE OVERHANG 2 4" -• , ,,'�o �Q INDICATED ON PLANS TO •/•onnt��� BE 1/5TH OF ALLOWABLE .-2'-11"-, 40'-8" -- • ATTACHMENT SPACING INDICATED ON PLANS . D2 SCALE:1/4"=1-0" s u n r u n PITCH:CH:23 23" AZIM:59° - 91 ' 40'-0" %--2'-T"-1} I 1'-10" — ❑ ❑ 0 EI I❑ 0 0 CI ' #180120 ¢ -0 {5' PHONE 0 "TYP 1.6 ES STANDISH BLw,.NwTON,MA,oneo-nsi 3'-5" FAX o n o c) h c O c) 0 CUSTOMER RESIDENCE: NATALICIA ALVES 28 THEATER COLONY RD, YARMOUTH,MA,02664 `.-J TEL.(774)271-5424 APN/TMK#:YARM-000060-000262 PROJECT NUMBER: 9'-3" 223R-028ALVE DESIGNER: (415)580-6920 ex3 STEVE GAILLOT SHEET LAYOUT REV:A 11/10/2021 PAGE PV-3.0 • 120/240 VAC SINGLE PHASE SERVICE SOLAREDGE TECHNOLOGIES: METER#: SE3800H-USS3 O METER URCE 2290809 3800 WATT INVERTER JUNCTION BOX PV MODULES n�AAAJ 1 OR EQUIVALENT LONGI GREEN ENERGY TECHNOLOGY UTILITY GRID—r— _ s «—✓- �— jr *�i// CO(11)MODULES LTD: OHPB 355M SUPPLY SIDE TAP v (0 OPTIMIZERS WIRED IN: }....„, --i $ I (1)SERIES OF(11)OPTIMIZERS (N)100A PV LOAD LOAD RATED DC DISCONNECT c_(5) CENTER WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS I COMPLIANT P401 (I EXISTING 100A 30 (N)LOCKABLE (N)MA SMART MAIN BREAKER BLADE TYPE UTILITY (N)LOCKABLE — It1 SOLAREDGE TECHNOLOGIES: I FUSED AC REVENUE BLADE TYPE SE6000H-USS3 DISCONNECT METER AC DISCONNECT 6000 WATT INVERTER JUNCTION BOX PV MODULES OR EQUIVALENT 4 j (-4(') (4 3b 2 (1 LONGI GREEN ENERGY TECHNOLOGY EXISTING (� Q / CO LTD:LR4 80HP8 355M ` 1M�AIN o�.o. ® * o�—e — `r _ �_/. I —�— I *(�j// (16)MODULES Y OPTIMIZERS WIRED IN: FACILITY — PANEL 60A FUSES I I (1)SERIES OF(16)OPTIMIZERS LOADS ..irtRoAtz SQUARE D 240V METER SOCKET SQUARE D 20A BREAKER(A) LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS DU222RB 35A BREAKER(B) WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R,BOA UTILITY SIDE OF CIRCUIT 3R,80A,2P COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- 120/240VAC (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3a 1"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHWTHWN-2 (1)8 AWG THHN/THWN-2 3b 1"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 PMS HONE Es arnuaeMBLVD,TAUNTON,MA,azreorx3t FNS0 O 5 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 CUSTOMER RESIDENCE: NATALICIA ALVES 28 THEATER COLONY RD, YARMOUTH,MA,02664 MODULE CHARACTERISTICS TEL.(774)271-5424 LONGI GREEN ENERGY P401 OPTIMIZER CHARACTERISTICS: APNITMK#:YARM-000060-000262 TECHNOLOGY CO LTD: MIN INPUT VOLTAGE: 8 VDC _ LR4 6OHP8 355M: 355 W MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 40.6 V MAX INPUT ISC: 11.75 ADC 223R-028ALVE MAX POWER VOLTAGE: 34.6 V MAX OUTPUT CURRENT: 15 ADC SHORT CIRCUIT CURRENT: 11.25 A DESIGNER: (415)5806920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM CHARACTERISTICS-INVERTER 2 STEVE GAILLOT SYSTEM SIZE: 3905 W SYSTEM SIZE: 5680 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 11 V SYSTEM OPEN CIRCUIT VOLTAGE: 16 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 11/10/2021 SYSTEM OPERATING CURRENT: 10.28 A SYSTEM OPERATING CURRENT: 14.95 A SYSTEM SHORT CIRCUIT CURRENT: 15 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 41. INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICALSHocKHAZARo PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. TERMINALS ON LINE AND LOAD MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED THE OPEN POSf LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011,PRODUCT SAFETY INVERTER(S),AC DISCONNECT(S),AC SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(0)(2),IFC 2012: SYSTEM e05.11.1.4 LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL, PER CODE(S):NEC 2020:705.12(C) }.; ( r I f: DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN O RAPID SHUT DOWN sunrun LABEL LOCATION: SWITCH PER CODE(S):NEC N 2020:690.56(CX2),IFC ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: ., 4• 705.12(B)(3X2) --, 1 U SOLAR PV SYSTEM EQUIPPED #180120 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN �µDISH�w TMMtaH lA�O2fmT}0 COMBINER PANEL Rro u FAx O DO NOT ADD LOADS CUSTOMER RESIDENCE: LABEL LOCATION: NATALICIA ALVES 28 THEATER COLONY RD, PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). YARMOUTH,MA,02664 PER CODE(S):NEC 2020:705.12(DX2X3Xc) 3" TURN RAPID SHUTDOWN SWITCH TO THE"OFF" TEL.(774)271-5424 PVPIMILS POSRION TO SHUT DOWN APN/TMK#:YARM-000060-000262 PV SYSTEM DISCONNECT PV SYSTEM AHD REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:40.83 AMPS SHOCK ARIARA Y W THE , 223R-028ALVE NOMINAL OPERATING AC VOLTAGE: 240 VAC DESIGNER: (415)580-6920 ex3 LABEL LOCATION: STEVE GAILLOT AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. t-` SHEETSIGNAGE PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 11/10/2021 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0 yM