Loading...
HomeMy WebLinkAboutEngineer Plans98 100 100 DE FENGE 50C 24.0 1 11 o ro I 000 03 fX15T. LEAGt11N ?2. PATIO z 1 TBM = 4 � e�. 100.0 T.o.F. rn 14. RA MYNEuLE pRIV� PR M SCALE: 1" = 20' Yarmouth Health Department APPROVED, I Name OV 1 8 ,2021 HEALTH DEPT. SURVEY BY: WELLER AND ASSOC. SOUTH YARMOUTH OLD TOWNHOUSE RD. IPA � o N 9 p �2 A LOCUS 24 MYNELLE DR. LEGEND �—� PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE TEST PIT SCALE: 1" = 20' Yarmouth Health Department APPROVED, I Name OV 1 8 ,2021 HEALTH DEPT. SURVEY BY: WELLER AND ASSOC. SOUTH YARMOUTH OLD TOWNHOUSE RD. IPA � o N 9 p �2 A LOCUS 24 MYNELLE DR. LOCUS MAP LOCUS INFORMATION TITLE REF: 21141/0193 PARCEL ID: MAP 088 PAR. 067 FLOOD ZONE: NOT IN FLOOD ZONE PROPERTY IN ZONE II SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 24 MYNELLE DRIVE SOUTH YARMOUTH, MA PREPARED FOR JEFFREY GONSALVES OCTOBER 1, 2021 REV: NOVEMBER 18, 2021 OF o DARREN M. 9. 1140140 � �NITAR�p� ill } MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 G� LOCUS MAP LOCUS INFORMATION TITLE REF: 21141/0193 PARCEL ID: MAP 088 PAR. 067 FLOOD ZONE: NOT IN FLOOD ZONE PROPERTY IN ZONE II SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 24 MYNELLE DRIVE SOUTH YARMOUTH, MA PREPARED FOR JEFFREY GONSALVES OCTOBER 1, 2021 REV: NOVEMBER 18, 2021 OF o DARREN M. 9. 1140140 � �NITAR�p� ill } MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS TOP OF FND. BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE EL.= 100.0 FINISHED GRADE 99.0 � F.G.EL: 99.20 1 TEE'S ARE TO BE 4" SCH 40 PVC EXISTING OUTLETSI I I. -I BAFFLE INV. 9 INV: 96.55 EXIST. 1,000 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TI1F-TITF- 7ABFL. OR FOUAL IVVICJ: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON AMECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPUCABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN - ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. S. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING PR TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 O 1/8"/FT (UNLESS SPECIFIED) 16. PROPERTY LOCATED WITHIN A ZONE OF CONTRIBUTION, NO ADDITIONAL FLOW/BEDROOMS ALLOWED. F.G. EL: 99.0 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA OF DOUBLE WASHED■ STONE4" SCH 40 PVC OR DEPTH 96.20 -•-• ]FISTRIBUTION :• • SEPTIC SYSTEM PROFILE INV. ELEV.= 96.0 3/4" - 1_1/2" DOUBLE WASHED STONE 3.5' I / EFFECTIVE LENGTH = 24' 1 TOP CONC. ELEV.= 97.0 INV. ELEV.= 96.0 �.� BOTTOM EL.= 94.0 - SEPARATION 5.50 FT. BOTTOM OF TESTHOLE EL: 88.50 - SOIL LOGS DATE: AUGUST 26, 2021 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH DEPT. Elev. TP -1 Depth 99.50 0" LOAMY SAND 10YR 3/2 99.00 El 6" USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 3.5' L1o��D STONE ON ENDS & SIDES: 24' L x 12' W x 2'D 96.83 C 32" BOTTOM AREA: 24 x 12 = 288 SF SIDE AREA: (24 + 12.5) X 2 X 2 = 144 SF TOTAL SQUARE FEET PROVIDED = 432 vs. 297.29 REQ'D MEDIUM SAND DESIGN FLOW PROVIDED: 0.74(432 S.F.) = 319.68 G.P.D. vs. 220 G.P.D. req'd 2.5Y 6/4 BREAKOUT ELEV.= 97.0 3.5' I 5 FT. I 3.5' EFFECTIVE WIDTH = 12' SOIL ABSORPTION SYSTEM (SECTION) (500 GALLON LEACH CHAMBER) DESIGN CRITERIA NUMBER OF BEDROOMS: 2BR DWELLING (NO INCREASE IN FLOW ALLOWED) SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 2 BR = DESIGN FLOW: 220 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 220 gpd x 200% = 440 gpd USE EXIST. 1,000G SEPTIC TANK LEACHING AREA REQUIRED: (220)/0.74 = 297.29 S.F. 88.50 1 132" PERC RATE <2 MIN/IN. ("C3" HORIZON) NO GROUNDWATER OBSERVED I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pumant to 310 CMR 15.017 to conduct sall woMuatlons and that the above analysis has been Performed by me consistent with the requirement• of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 124 MYNELLE DRIVE, SOUTH YARMOUTH, MA DRIVE, SOUTH YARMOUTH, MA Design and Site Plan by: for: MEYER & SONS, INC. Po BOX 981 EAST S4NDW/CH, MA 02537 508362-2922 Gonsalves SCALE DRAWN N.T.S. DMM REV DATE CHECKED 11/18/21 DMM 10/01/21 SHEET NO. 2of2