Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. I io. Lot Z7 Zone of Contribution: In Out X( Acreage `?Z yrs Commercial: Residential: ✓ Street: 3 Z . ---N-, --E I-- Village: ,ru Floor Plan: IV #Bedrooms: 1 Owner: p A- JA,r_ Installer Q j i FX c;Q.o ) [,,a(� CO fl Address: Phone:` '9j(4 .3 ' Phone: Builder: Engineer: /-1 c Address: Phone: Phone: N/A YES NO 1.Required#of copies received </ 2.Date of soils exam and percolation test not older than 2 years V 3. 4-5 ft of naturally occurring pervious material,above water table 7/ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ J 3 5.Water line 10 ft from septic components Var.: 5 c.e 'E ✓ ✓ u,c. I< 6. Benchmark indicated and shown-NGVD if near wetlands I 4,0Az 7. Septic tank minimum 10 ft from foundation, deck Var.: / 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: S ` / 9. Leaching minimum 100 ft from wetlands Var.: 25 ` 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: S ' SA-5 12. System meets all other setback requirements Var.: ./- 13. 13. Uses adjustment for maximum high groundwater Var.: T1 oAC t c hSc v t 2' ✓ ,al.‘ 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 2 15. System not in top or subsoil(A,B horizons)or 5'removal s/ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred 1 ✓ 18. System meets breakout requirements PVC liner: Wall: f f 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel d 21.No garbage disposal ✓✓ 22. System adequately sized for its intended use /ft-II ', ,/ [+a3 23.Minimum 6"stone or compacted below tank and dbox / 24. Manhole covers within 6"of grade,pump chamber cover to grade 5/ 25. Inspection port on plastic chambers/leach field V / 171 26. Electrical permit for pump chamber/Separate meter for duplexes ./ , 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size V 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber ,/ 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehiculartr water _ \/ 34.Title V Application and permit fee i si ature 1.7 35. Foundation footing min. 2 feet above adjusted gro er for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd ( ✓ 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: � '1'et-V4-- 6 03 03 b 21' N