Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH 'ID SEWAGE PLAN REVIEW CHECKLIST 33 Location: A.M. --96.-- Lot Zone of Contribution: In Out ✓ Acreage o-VS A Commercial: Residential: v Street: /3 c ,vo 1.4 1-419-7 .c' Sr Village: 5c v i)-1 Floor Plan: #Bedrooms: 4 Owner: Et-T.)xi .44..._7 Installer: L' t--/ //=e,"---/-"D Address: ---- Address: Phone: Phone: Builder: Engineer: v`,4- Address: Phone: Phone: N/A YES/ NO 1.Required#of copies received ,/ / 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,/ 5.Water line 10 ft from septic components Var.: ix)x,ft 5110...,u i.---- 6. 6.Benchmark indicated and shown-NGVD if near wetlands / 7. Septic tank minimum 10 ft from foundation,deck Var.: / 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: / 9.Leaching minimum 100 ft from wetlands Var.: / 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: / 11.Tank/leaching minimum 10 ft from property line Var.: V 12. System meets all other setback requirements Var.: ti..4.-7 v Ar47 13.Uses adjustment for maximum high groundwater Var.: / / 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: ✓ 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable / 17. System meets slope requirements-min. 1/8", '4"preferred V 18. System meets breakout requirements 51 cam*-- PVC liner: Wall: ✓ 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel ✓ 21.No garbage disposal ,/ 22. System adequately sized for its intended use ,/ 23.Minimum 6"stone or compacted below tank and dbox ✓ 24. Manhole covers within 6"of grade,pump chamber cover to grade ,/ 25. Inspection port on plastic chambers/leach field ,/ 26. Electrical permit for pump chamber/Separate meter for duplexes ✓ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ,/ 28. Septic tank/pump chamber to be factory waterproofed / 29.Vent provided if leaching below 3 feet,under driveway/parking ./ 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: T 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature x/ 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee,installer signature ../ 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: "e-72:› 6 03 03