HomeMy WebLinkAboutEngineer PlansACCESS COVERS MUST BE WITHIN INSPECTION 9' MINIMUM. 6' OF FINISH GRAD PORT 3' MAXIMUM COVER 102.38 FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE 4' DIAM PIPE 3/4' - 1 I/2' DIA. 100:0 98.0 97.0 IO"F7 �. DOUBLE WASHED STONE OAS 98.25 BAFFLE 97.17 96.83 96. 3 OUTLET 4 HIGH CAPACITY INFILTRATOR O -BOX CHAMBERS W/3.5.3 STONE AROUND 1500 GAL l0'• x 38'1 x /0'd SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROF / L E: NOT TO SCALE INVERT ELEVATIONS GENERAL NOTES: INVERT AT BUILDING: 100.0 INVERT /N SEPTIC TANK: 98.25 INVERT OUT SEPTIC TANK: 98.0 INVERT /N DIST. BOX: 97.17 INVERT OUT DIST. BOX: 97.0 INVERT /N LEACH CHAMBER: 96.83 BOTTOM OF LEACH CHAMBER: 96.0 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A ffb'TTOM OF TEST HOLE •1: 89.5 X _ + LEGEND ■ CB CONCRETE BOUND .� \ �. j -W- WATER LINE LOCUS O HYDRANT - --'� -G- GAS L f NE rk'INQLtl4'� I ! �-/1'•� .- -OHW- OVER HEAD WIRES L 16HT POST -E?- UNDERGROUND ELECTRIC L / NE / -T- UNDERGROUND TELEPHONE LINE CTV- UNDERGROUND CABLEV / S ION L / NE + 40.4 SPOT ELEVATION -40 EXISTING CONTOUR Rol _- PROPOSED CONTOUR L 000S MAP O l0 20 40 DESIGN CRITERIA: GENERAL NOTES: DESIGN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER 1. 05.00 BEDROOM EQUALS 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER E VERTICAL DATUM IS ASSUMED, FOR BENCH MARKS I2' N 77.50 OQ K HIGH CAPACITY 330 G.P.D. X 200% - 660 GAL. 3. ,1 INFILTRATOR CHAMBERS MAINTENANCE OF THE SEPTIC SYSTEM SHALL SAND 4/4 N/3. 5'+ STONE AROUND SOIL ABSORPTION SYSTEM REQUIRED: ,, o DESIGN PERC RATE ( 5 MIN/INCH M . n 1 SOIL TEXTURAL CLASS - I 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED THAN 3" IN DEPTH SHALL BE CAPABLE OF WITH- A / C, LOT //0 lo STANDING H-20 WHEEL LOADS. z4, D -BOX ya'i FrIR!JK a 10.500± S.F. SHOWER BEDROOM r ^; 460 S.F. x 0.74 - 340 GPD r APPROVED EQUAL. r 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED SOIL TEST PIT DA TA & BEDROOM Q BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE OATH PERCOLATION = OBSERVED - IS MORE THAN ONE OUTLET. EGALLON , % /7 g�TCN SPT SEPTIC TANK TP •1 I -888 -DIG -SAFE AND THE LOCAL WATER DEPT. LIVING CESSPOOLS nqx' -• , y In ROS DINING BM CORNER`STEP Ir, EXISTING CESSPOOLS TO BE PUMPED DRY AND Z _ y EL 102.54 . 1 '4 q4n PERC RATE: l 2 MIN/INCH 1�0_AX BREEZEWAY GZ o WALK / GARAGE ,... "� DBIYE Za'\ PAVED a- 105.00' O a50.p0•W s b X _ + LEGEND ■ CB CONCRETE BOUND .� \ �. j -W- WATER LINE LOCUS O HYDRANT - --'� -G- GAS L f NE rk'INQLtl4'� I ! �-/1'•� .- -OHW- OVER HEAD WIRES L 16HT POST -E?- UNDERGROUND ELECTRIC L / NE / -T- UNDERGROUND TELEPHONE LINE CTV- UNDERGROUND CABLEV / S ION L / NE + 40.4 SPOT ELEVATION -40 EXISTING CONTOUR Rol _- PROPOSED CONTOUR L 000S MAP O l0 20 40 DESIGN CRITERIA: GENERAL NOTES: DESIGN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BEDROOM EQUALS 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER 2. VERTICAL DATUM IS ASSUMED, FOR BENCH MARKS I2' SET. SEE SITE PLAN. SEPTIC TANK REQUIRED: 330 G.P.D. X 200% - 660 GAL. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND SEPTIC TANK PROVIDED: 1500 GAL, MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL SAND 4/4 CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - I 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED THAN 3" IN DEPTH SHALL BE CAPABLE OF WITH- A / C, 50' STANDING H-20 WHEEL LOADS. PROVIDED: 4 HIGH CAPACITY INFILTRATOR ya'i FrIR!JK a CHAMBERS W/3.5't STONE AROUND. A-460 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR 460 S.F. x 0.74 - 340 GPD r APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED SOIL TEST PIT DA TA & PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE INDICATES IND/CA TES PERCOLATION = OBSERVED IS MORE THAN ONE OUTLET. TEST GROUNDWATER % /7 7. BEFORE CONSTRUCTION CALL "DIG -SAFE'. TP •1 I -888 -DIG -SAFE AND THE LOCAL WATER DEPT. HORIZON TEXTURE COLOR DATE: MARCH 20, 2008 FOR LOCATION OF UNDERGROUND UTILITIES. 0. 99.5 FILL 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. 7' _ _ _ 98.9 A LOAMY /OYR SAND 4/1 I2' _......,, _... 98.5 B LOAMY 7.5YR SAND 4/4 MED I UM I OYR C / SAND 5/8 A / C, 50' ya'i FrIR!JK a r a N0,-W'ATEt % /7 120' 89.5 DATE: MARCH 20, 2008 TEST BY: STEPHEN HAAS WITNESSED BY: PHIL RENAUD PERC RATE: l 2 MIN/INCH A g'i ►f ns Yanmou-t?i ealth Department ►�0 3�"saLs� APPROVED �p�F„�. Alot '� N Date j SEF'T/C SYSTEM LEES /GN / / 3 W / /VD / /VG BROOK ROAO . MAP 66. PARCEL 21 / SOUTH YARMOUTH, "A . PREPARED FOR GE OR GE A N T14 YA SCAL E : / " - 20' APR / L 4 . 2008 EAGLE SURVEY I NG , I NC 923 Route 6A �z Yorrnouthport MA. 02675 ( 508) 362-8132 ( 508) 432-5333 4