HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. -(6, Lot 25 Zone of Contribution: In Out_ Acreage 3 7'13 2 *' 5•F
Commercial: Residential: r.-
Street: 20 5 14-i 4 4 t L.,S e,Lo-...s c_cL
Village: w s i Floor Plan: #Bedrooms: '
Owner: Fc.--ii-v L c Installer: 56. o--(-0 ,L. )-T-r-t
Address: Phone:
Phone:
Builder: Engineer: -DerA..ru - "
Address: Phone:
Phone:
N/A YES/ NO
1.Required#of copies received �/
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: /
6.Benchmark indicated and shown-NGVD if near wetlands L//
7. Septic tank minimum 10 ft from foundation, deck Var.: ,/
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V
9.Leaching minimum 100 ft from wetlands Var.: /
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓ /
11.Tank/leaching minimum 10 ft from property line Var.: �✓
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: ✓
14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: /I ✓
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", 'A"preferred
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper,gas baffle on outlet tee i/
20. Sewage is under 10,000 gpd for parcel /
21.No garbage disposal ✓
22. System adequately sized for its intended use /
23.Minimum 6"stone or compacted below tank and dbox ✓
24. Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes f
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed -
29.Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber 1 r
31.Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature j
33.H-20 loading is subject to vehicular traffic,groundwater ,/
34.Title V Application and permit fee,installer signature
35.Foundation footing min.2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd ✓ _
37.Check area lots for groundwater/Label groundwater in As essor's Map
Plan reviewed b . d -+�4 • c �t / Z��
Y' �l a o;o;