Loading...
HomeMy WebLinkAboutEngineer PlanLOCATION MAP LOT 52 (9,360 SF) ASSESSORS MAP: 32 PARCEL: 34 PLAN BOOK: 91, PAGE: 41 EXISTING CONTOUR: – — — – PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: -* UTILITY POLE: –O– FENCE LINE: - HYDRANT:. RETAINING WALL: oI LEACH AREA DETAIL SEPTIC SYSTEM DESIGN FLOW ESTIMATE: _3 BEDROOMS AT 110 GAL/DAY= 330 GAL/DAY SEPTIC TANK: 330 GAL/DAY x2 DAYS= 660 GAL USE 1000 GALLON SEPTIC TANK (EXISTING) .EACHING AREA: USE 5 - 125 GALLON CHAMBERS (6.1'x 3'x 12" EFF. DEPTH) WITH 4' OF STONE AROUND SIDES AND 2' AT ENDS (34.5'x I V x 12" EFF.) SIDE AREA: (34.5' + 11') x 2 x 1 = 91 SF (0.74) m_67 GAUDAY BOTTOM AREA: 34.5' x 11' = 379 SF (0.74) = 280 GAUDAY CAPACITY= 347 GAUDAY REQUIRED VARIANCE FROM TITLE FIVE: 1. SECTION 15.212: LEACH AREA TO BE LESS THAN 5' ABOVE GROUND WATER (VARIANCE OF 0.09'). Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. :Board of Health review and approval is required for any future additionstrenovatious/alterations to sewage facilities and/or structures/dwelling. Yarmouth llcalth Dcparlment APPROVED SEPTIC SYSTEM SECTION 1000 GAL SEPTIC TANK TEE SIZES: (TO BE CONFIRMED) INLET: 6" U 13" DOWN OUTLET: 6' UP, 14" DOWN 1/8" per It 1/8" per It ( "`"' D -BOX "`"' MECHANICALLY COMPACTED) -GAS BAFFLE AT OUTLET TEE BED BATH ROOM BATH I TEST HOLE LOGS ROOF ROOM Ic ENGINEER: THOMAS McLELLAN, P.E. LOSET WITNESS: PHIL REAULD DATE: 1-20-22 BED PERCOLATION RATE: a 2 MIN/IN OPEN TO BELOW ROOM 2nd FLOOR. USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: B,. ADJ. (DEC): 2.2' ADJUSTED GROUND WATER ELEV.= 91.2 DECK SH DINING KITCHEN iwvv ROOM BATH RM. LIVING ROOM \. GARAGE_ -DECK 4 1St. FLOOR EXISTING FLOOR PLAN I FEB 14 2022 r�EALTH DEPT NOTES: ' PEASTONE OR FILTER FABRIC OELEWASHED SDOUBLE N INSPECTION PORT � ELEV.= 97.94 < —34.5'x IV WITH 4 OF STONE AROUND(SIDES AND 2' AT ENDS (34.5' x 11' x 12" EFF. DEPTH) ADJUSTED GROUND WATER ELEVATION = 91.2 TH-1 100.0 O/A HORIZON ELEV. LOAMY SAND 6" 10YR 4/1 99.5 B HORIZON LOAMY SAND 24" 10YR 5/6 98.0 C HORIZON MEDIUM SAND 2.5Y 7/4 _ PERO AT 42" 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4' PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). - _ -- 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS, ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF. ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3' WITHOUT VARIANCE. 11, FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND -- PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES. NOT REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING LEACH PIT IS TO. BE PUMPED AND REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. MCLELLAN CIVIL No. 88471 LIt7wyr ' THOMAS J. McLELLAN, P.E. SITE PLAN LOCATION: 38 RUBY ST., W. YARMOUTH, MA PREPARED FOR: DEREK RITCHIE DATE: 1-21-22 SCALE: 1" = 20' BASS RIVER ENGINEERIN%"? P.O. BOX 1163, EAST DENNIS, MA 02647~ 508-364-9048