HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH ! �.
y
•
SEWAGE PLAN REVIEW CHECKLIST
, E--.
Location: A.M. 32 Lot 3`+' Zone of Contribution: In Out ✓ Acreage 9360 SF
Commercial: Residential: ••-----
Street:
Street: 38 (2-ti 6 q sr.
Village: -5rr Floor Plan: #Bedrooms: 3
Owner: kitL�S Installer: D d'L-
Address: Phone: _
Phone:
Builder: Engineer: b '5 cv --•<._____
Address: _ _ Phone:
Phone:
N/A YES NO
1.Required#of copies received /)or 7 kL�
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table V
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓
5.Water line 10 ft from septic components Var.: I /
6.Benchmark indicated and shown-NGVD if near wetlands /
7. Septic tank minimum 10 ft from foundation,deck Var.: 6.k is T ✓
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: /
9.Leaching minimum 100 ft from wetlands Var.: V
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.: /
12. System meets all other setback requirements Var.: ✓
13.Uses adjustment for maximum high groundwater Var.: V
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: o.09' V
_ 15. System not in top or subsoil(A,B horizons)or 5' removal ✓
16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", %"preferred V
18. System meets breakout requirements PVC liner: Wall: V
19. Specified tee sizes are proper, gas baffle on outlet tee ✓
20. Sewage is under 10,000 gpd for parcel V
21.No garbage disposal V
22. System adequately sized for its intended use V
23.Minimum 6"stone or compacted below tank and dbox V
24.Manhole covers within 6"of grade,pump chamber cover to grade ✓
25.Inspection port on plastic chambers/leach field V
26. Electrical permit for pump chamber/Separate meter for duplexes /
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓
28. Septic tank/pump chamber to be factory waterproofed ,/
29.Vent provided if leaching below 3 feet,under driveway/parking ,/
30.Buoyancy calculations for tank/pump chamber V
31.Engineer to inspect and certify soils: wall: commercial: ,✓
32. Engineer/Registered Sanitarian . -• an. Surve • stamps/signature /
33.H-20 loading is subject to vehic . . ` ,groundwater ,/
34.Title V Application and permit fee,installer signature ✓
35.Foundation footing min.2 feet above adjusted ground water for new house ✓
36.Deed Restriction required max. #bedrooms: max.flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map /
Plan reviewed by: '''‘6.713-4"--"A---) l2.111 l2ozz_
6c70?