HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
36- /6
Location: A.M. Lot o2 g Zone of Contribution: In Out Acreage 1770
Commercial: Residential: r...----
Street:
/Street: 8 7 Gje N ch..,q rci (..30-
/
Village: Floor Plan: #Bedrooms: '%
Owner: (.0 i.Hi'ft An. fl'N IV Installer: p 01 13 2 )(C a vctii c,)1,7
Address: oZ 1 � rr i,.e r S - R a j Phone: 5O g 4/77- O 6 .51
Phone:
Builder: Engineer: {.c ri.).5' iv e.e r"0 "'5 p`)r k S .iv c--
Address: Phone: 5-0 g - L/7 7 - 53 /3
Phone:
N/A YES NO
1.Required#of copies received 2 -
2.Date of soils exam and percolation test not older than 2 years V-
3.4-5 ft of naturally occurring pervious material,above water table 1,/'
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: fr/
5.Water line 10 ft from septic components Var.: f�
6.Benchmark indicated and shown-NGVD if near wetlands Y
7. Septic tank minimum 10 ft from foundation,deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: V
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V ri
11.Tank/leaching minimum 10 ft from property line Var.: V
12. System meets all other setback requirements Var.: / V
13.Uses adjustment for maximum high groundwater Var.: - t V
14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: V
15. System not in top or subsoil(A,B horizons)or 5' removal 1 V
16.Proposed contours are suitable �'
17. System meets slope requirements-min. 1/8", 1/4"preferred �/
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper,gas baffle on outlet tee V
20. Sewage is under 10,000 gpd for parcel 'V
21.No garbage disposal
22. System adequately sized for its intended use V
23.Minimum 6"stone or compacted below tank and dbox ler-
24.Manhole covers within 6"of grade,pump chamber cover to grade r/
25. Inspection port on plastic chambers/leach field ,�
26.Electrical permit for pump chamber/Separate meter for duplexes ✓
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ;/
28. Septic tank/pump chamber to be factory waterproofed V
29. Vent provided if leaching below 3 feet,under driveway/parking V
30.Buoyancy calculations for tank/pump chamber V
31. Engineer to inspect and certify soils: wall: commercial: Y/
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater 7
34.Title V Application and permit fee,installer signature
35.Foundation footing min.2 feet above adjusted ground water for new house V
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map /
Plan reviewed
/
_ `-- 60303