Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH m fl 6 _ 3 SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot f ( Zone of Contribution: In Out V Acreage /G,, Ogg Commercial: Residential: I/ Street: S3 e a S a N--t S-t Village: II Floor Plan: #Bedrooms: Owner:R i G L rct G D e r m oft Installer: PK rn C o n.)11"'q C.-t°r- �N e Address: Phone: 5-0 3 8 s Sc!9.3 Phone: SD $ 3 R - L/6 g iv Builder: Engineer: Dow r7 Ca k nJ N e e r i +ig Address: Phone: SO 3 - 4/3-4i/ Phone: N/A YES NO 1.Required#of copies received V 2.Date of soils exam and percolation test not older than 2 years t/- 3.4-5 /3.4-5 ft of naturally occurring pervious material,above water table V' 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,d/ 5.Water line 10 ft from septic components Var.: e 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation,deck Var.: V 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V 9. Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: Nrg V 12. System meets all other setback requirements Var.: w/ 13.Uses adjustment for maximum high groundwater Var.: V 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: V________`_ 15. System not in top or subsoil(A,B horizons)or 5' removal I ✓ ' 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '4"preferred 18. System meets breakout requirements PVC liner: Wall: I 19. Specified tee sizes are proper, gas baffle on outlet tee V 20. Sewage is under 10,000 gpd for parcel NO21.No garbage disposal 1 V 22. System adequately sized for its intended use V 23.Minimum 6"stone or compacted below tank and dbox V 24.Manhole covers within 6"of grade,pump chamber cover to grade V 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size // 28. Septic tank/pump chamber to be factory waterproofed ✓ 29.Vent provided if leaching below 3 feet,under driveway/parking ✓" 30.Buoyancy calculations for tank/pump chamber V 31.Engineer to inspect and certify soils: wall: commercial: V 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 1 V 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee,installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house ,✓ 36.Deed Restriction required max. #bedrooms: max. flow: gpd A/ / 37. Check area lots for groundwater/Label groundwater in Assessor's Map V Plan reviewed bv: u_,tv- 60303