HomeMy WebLinkAboutEngineer PlanSYSTEM PROFILE SYSTEM WTH MA�ET�A,E BE (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2' PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE \ TOP FOUND. EL. 15.1' FILTER FABRIC OVER STONE 13.7' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 13.5 PRECAST H-10 WATERTEW D'BOX FOR LEVELNESS BLOCKS OR A RISERS (IYP.) MIN. 2 CKNESmsS PRECAST RISERS 2•m 4"CH40 PVC MORTAR ALL INVERT IN 9.67' 111.22' PIPES LEVEL IST 2' 4• COMPONENTS 4, B ENDS .r (NP.) _ SIDES 11 10' 1500 GAL H-10 14• - - 111.22' 10.27' TEE SEPTIC TANK TEE 10.02' 6" MIN SUMP ®®®® ®®®® ®® y.� ° ®®®®®®®®®®® ®®®®®®®®®®® GAS 12" MIN. INT. DIM. ®®®®®®®®®®® ®®®®®®®®®®® ®®®®®®®®®®® ®®f 55®®®®®®®® 4' UQ. LEVEL (ACME OR EQUAL)1' 9.94' 9.77' `H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQ( +00,o,,°,04°°°°o°++°n°o°o°o°o°^°^°^°^°°°o°o 3/4" 2" DOUBLE WASHED STONE 4' MIN. ALL AROUND PRECAST STRUCTURES I(3) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.5' X 12.83' COMPACTION. (15.221 (23) (--L% % SLOPE) (--L% % SLOPE) A — 38'SEPTIC TANK 8' D' BOX 12' LEACHING FACILITY 2.5' BOTTOM TH-1 B 22' � �1n NO GROUNDWATER FOUND (-L5-% % MIN. SLOPE) LEGEND — 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99}-- PROPOSED CONTOUR [98•4] PROPOSED SPOT EL. THi 0 DLocus TEST HOLE Zg o SLOPE OF GROUND BED UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 1/13/22 PERC. RATE _ < 2 MIN/INCH _ CLASS I SOILS 4 ELEV. 1 0" 13.0' A LS 9>, 1OYR 3/2 B LS 22" 1OYR 4/6 11.17' C PERC M/CS 2.5Y 7/4 126" I 2.5' NO GROUNDWATER ENCOUNTERED DICE #21-461 Scale: 1 "= 20' 0 10 20 30 40 50 FEET *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM IVU 1 t5 1. DATUM IS NAW 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE +ATH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CAWNG DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTIUTIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 61 PARCEL 3 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (•2 PCT ANNUAL FLOOD HAZARD) AS SHOWN AND REMOVED OR PUMPED AND FILLED WITH CLEAN ON COMMUNITY PANEL #25001CO591J DATED SAND. 7/16/2014 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. FIRST FLOOR PLAN (N.T.S) d � Pp0 00 Pine goo SC 00 0 0 DLocus BED Zg o o t. 28 BED Pond St. 96` 2— W C� 00 AOIf `� BED BATH Wil/ow SI. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CAWNG DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTIUTIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1"=2000'± 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 61 PARCEL 3 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X 12. EXISTING LEACHING FACILITY SHALL BE PUMPED (•2 PCT ANNUAL FLOOD HAZARD) AS SHOWN AND REMOVED OR PUMPED AND FILLED WITH CLEAN ON COMMUNITY PANEL #25001CO591J DATED SAND. 7/16/2014 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. FIRST FLOOR PLAN (N.T.S) SECOND FLOOR PLAN (N.T.S) -Z-3_Zz DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.8 (.74) = 317 GPD TOTAL: 614 S.F. 454 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND • Cu.C�� Y--' �d��MA APPROVE DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 53 PLEASANT ST SOUTH YARMOUTH, MA PREPARED FOR RICHARD & MARGARET MCDERMOTT DATE: FEBRUARY 3, 2022 off 508-362-4541 fax 508-362-9880 downcope.com down rape engineering, h7C. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 21-461 MCDERMOTT.DWG BED BED BED BED BATH BATH SECOND FLOOR PLAN (N.T.S) -Z-3_Zz DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.8 (.74) = 317 GPD TOTAL: 614 S.F. 454 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND • Cu.C�� Y--' �d��MA APPROVE DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 53 PLEASANT ST SOUTH YARMOUTH, MA PREPARED FOR RICHARD & MARGARET MCDERMOTT DATE: FEBRUARY 3, 2022 off 508-362-4541 fax 508-362-9880 downcope.com down rape engineering, h7C. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 21-461 MCDERMOTT.DWG