HomeMy WebLinkAboutReview Checklist i i TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 02 0Lot7gZone of Contribution: In Out V Acreage C�73 f ` Commercial: Residential: V'' Street: 6 6 Pa,r k _0 v 2 Village: Floor Plan:_ #Bedrooms: 3 Owner: fl I c c 3 q rV clf Q Installer: C A Pi CcJ -5 e pfi c• Ser Vic 4 Address: Phone: .3 D 716 - a eci.S" Phone: 4 / 7 3a 9 9/ 6 0 Builder: - Engineer: A� k C A �� S c Pf i G Address: Phone: 5'0 771 1/a 0 O Phone: N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years ✓ 3.4-5 ft of naturally occurring pervious material,above water table 17 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: / --- 6.Benchmark indicated and shown-NGVD if near wetlands !1 7. Septic tank minimum 10 from foundation,deck Var.: 8.Leaching minimum 2 ft fu915 ft crawl, 10 ft slab Var.: 3` V/ 9.Leaching minimum 100 ft from wetlands Var.: /6 ' >s- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: V 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: V-- 15. System not in top or subsoil(A,B horizons)or 5'removal ✓ 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/"preferred V 18. System meets breakout requirements PVC liner: Wall: V. 19. Specified tee sizes are proper, gas baffle on outlet tee F/ 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal V 22. System adequately sized for its intended use I . 23.Minimum 6"stone or compacted below tank and dbox V 24. Manhole covers within 6"of grade,pump chamber cover to grade 1,--- 25. /25. Inspection port on plastic chambers/leach field 26. Electrical permit forpump chamber/Separate meter for duplexes - t/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓ - 28. Septic tank/pump chamber to be factory waterproofed V 29.Vent provided if leaching below 3 feet,under driveway/parking V 30. Buoyancy calculations for tank/pump chamber V 31. Engineer to inspect and certify soils: wall: commercial: u---- 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature _ V 33.H-20 loading is subject to vehicular traffic,groundwater I/ 34.Title V Application and permit fee,installer signature V 35.Foundation footing min.2 feet above adjusted ground water for new house V 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by.x____„,r.,f__s5cu._,s 6oa 03