HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 3 7 Lot { Zone of Contribution: In Out /Acreage /0 89 0
V.
Street: '4/7- L7 7 - -/3 o fie r- A LieCommercial: Residential:
Village: Floor Plan: t . #Bedrooms: 6.
Owner: u th C o i J e r Installer: q u i iv nuS LAXC,'�cil
/1 o x'
Address: Phone: 774/- 37.71. - 0078
Phone: D g - 7,1.1- 7/z/O
Builder: Engineer: E 5;a>,e-e r; ,ti. o r/Cs
Address: Phone: 3'0 g A/7 7- 3-3/3
Phone:
N/A YES NO
1. Required#of copies received V
2.Date of soils exam and percolation test not older than 2 years V'
3.4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands V
7. Septic tank minimum 10 ft from foundation,deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: I
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.: ✓
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.:
V.
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: tr
15. System not in top or subsoil(A,B horizons)or 5'removal
16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall: 1 '
19. Specified tee sizes are proper,gas baffle on outlet tee f_
20. Sewage is under 10,000 gpd for parcel ,70
21.No garbage disposal '\.,
22. System adequately sized for its intended use
--> 23.Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade, pump chamber cover to grade 17'
25. Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes ✓
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size (/'
28. Septic tank/pump chamber to be factory waterproofed \/
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: V
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature _ f'
33.H-20 loading is subject to vehicular traffic,groundwater j f
34.Title V Application and permit fee,installer signature
35.Foundation footing min.2 feet above adjusted ground water for new house V
36.Deed Restriction required max. #bedrooms: max. flow: gpd V I
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed b . C2.4,01-:'
.4..� 6 03 03